Modular analyzer system – flexible configuration, options tailored for almost any application Emission monitoring according to EN 15267 • Emission measurements of very low concentrations, e.g. in power plants, cement plants or waste incineration plants and in the pulp and paper industry • With the analysis module DEFOR, the specialist for gas turbines due to measurement of very low SO2, NO and NO2 concentrations • Monitoring of NOx in denitrification plants by direct measurement of NO and NO2 as well as compiling to NOx in the analyzer • Efficient measurement in denitrification plants •...
Abrir o catálogo na página 2
Extractive gas analyzers GMS800 4 types of enclosures for easy integration at the installation location 19" rack housing with integrated control unit (BCU), 4 rack units, IP 40 Wall enclosure, IP 65 for use in rough industrial environment, optionally usable in explosion zones 1 and 2 Flame-proof enclosure, IP 65, for use in explosion zone 1 Type GMS811: 19"rack housing with 4 rack units, IP 40 Type GMS840: Wall enclosure, IP 65 for use in rough industrial environment, optionally usable in explosion zone 2 6 Analyzer modules for more than 60 gases DEFOR Modern UV gas analyzer for...
Abrir o catálogo na página 3
TAILOR-MADE GAS ANALYSIS SOLUTIONS FOR PROCESS AND EMISSION MONITORING Additional information Product description familiy of extractive analyzers which can measure more than 60 different gas ized by its modular design: 7 analyzing modules, one gas module, I/O modules and an operating unit. Standardized 19" racks as well as system enclosures opti- mized for installation in cabinets can be • 7 different analyzer modules: DEF0R (NDUV, UVRAS), MULT0R (NDIR), • 5 different types of enclosures Your benefits Ex-areas (Zone 1 and 2 according to ATEX) possible • Minimum service and maintenance work...
Abrir o catálogo na página 4
Extractive gas analyzers GMS800 Fields of application • Emission monitoring according to EN 15267 and process gas measurements • Emission monitoring of very low concentrations • Measurement of smallest concentrations of NO, NO2 and SO2 • NOx monitoring by direct measurement of NO and NO2 • Measurement of sulfur compounds in process gases • CO monitoring for Ex protection • Measurement of smallest concentrations in hydrogen or hydrocarbons Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on...
Abrir o catálogo na página 5
GMS800 Extractive gas analyzers GMS811 design Description 19″ rack enclosure with 4 rack units, for usage with separate control unit (BCU), for integration in cabinets Enclosure rating Power supply Voltage Frequency Power consumption PVDF bulkhead fitting For hose 6 x 1 mm For purge gas or flowing reference gas Option Gas connections: Swagelok 6 mm or Swagelok 1/4″ Wall-mounting enclosure with gas-tight separated analyzing and electronic units, purgable separately Ex-approvals ATEX II 3G Ex nR II T6 II 3G Ex pz II T6 In combination with an external, approved monitoring unit (option) II 2G...
Abrir o catálogo na página 6
Extractive gas analyzers GMS800 GMS820P design Description Flame-proof enclosure for use in Ex-zone 1 areas Ex-approvals IECEx Enclosure rating Power supply Voltage Frequency Power consumption For purge gas or flowing reference gas Option Gas connections: Swagelok 6 mm or Swagelok 1/4″ GMS840 design Ambient temperature Storage temperature Ambient humidity Ex-approvals ATEX NEC/CEC (US/CA) GMS841: Ex nA nC IIC T4 Gc Ex nA nC [ia Ga] IIC T4 Gc GMS842: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx nA nC IIC T4 Gc Ex nA nC IIC Electrical safety Enclosure rating Power supply...
Abrir o catálogo na página 7
GMS800 Extractive gas analyzers DEFOR analyzer module Description UV gas analyzer for simultaneous measurement of up to 3 gas components Measurement principles NDUV spectroscopy, UVRA spectroscopy 0 ... 10 ppm / 0 ... 100 Vol.-% NO2, SO2: smallest measuring range with daily adjustment of zero point and operation in air-conditioned ambiance with a temperature stability of ±2 °C (*) Response time 4 s Typical at 60 l/h, depending on cell length and gas flow Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of measuring range full scale per week Measuring...
Abrir o catálogo na página 8
Response time ≤ 25 s At 60 l/h, depending on cuvette length, gas flow and number of measuring components Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 % of smallest measuring range per week Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV German Clean Air Regulations EN 15267 EN 14181 MCERTS Corrective functions Manual or automatic adjustment with test gases or adjustment cuvette Test functions Self...
Abrir o catálogo na página 9
GMS800 Extractive gas analyzers Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller 5 vol%: ≤ 0.05 Vol.-% per week Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV German Clean Air Regulations EN 15267 EN 14181 MCERTS Corrective functions Manual or automatic adjustment with test gases Test functions Self test and fault diagnosis Special versions with highly solvent-resistant or highly corrosion-resistant measuring cells available THERMOR analyzer module Description Heat conductivity analyzer for the...
Abrir o catálogo na página 10
Extractive gas analyzers GMS800 UNOR analyzer module Description Highly selective NDIR analyzer for continuous measurement of almost any gas component which absorbs in the infra-red spectral range Measurement principles NDIR spectroscopy 0 ... 26 ppm / 0 ... 100 Vol.-% More than 60 measuring components available Response time 3 s Typical at 60 l/h, depending on cell length and gas flow Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 % of smallest...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos SICK SENSOR INTELLIGENCE
-
Opto-Electronic Protective Devices
32 Páginas
-
REGISTRATION SENSORS
24 Páginas
-
CLV63x, CLV64x, CLV65x
102 Páginas
-
WTB16 Bluetooth®
135 Páginas
-
WE9LC-3_A71
3 Páginas
-
Safety Switches
20 Páginas
-
Automation light grids
8 Páginas
-
Encoders and Inclination Sensors
32 Páginas
-
Proximity Sensors
324 Páginas
-
Dust measuring devices
172 Páginas
-
Detection and Ranging Solutions
124 Páginas
-
Distance Sensors
404 Páginas
-
Vision
124 Páginas
-
Top-Products from SICK
556 Páginas
-
Fluid Sensors
243 Páginas
-
Registration Sensors
276 Páginas
-
Magnetic Cylinder Sensors
164 Páginas
-
IDENTIFICATION SOLUTIONS
24 Páginas
-
Our identification solutions
8 Páginas
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Páginas
-
FLOWSIC300 Gas flow meters
12 Páginas
-
FLOWSIC500 Gas flow meters
16 Páginas
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Páginas
-
FLOWSIC600 Gas Flow Meter
16 Páginas
-
ConVer
12 Páginas
-
GM32 In-situ gas analyzers
28 Páginas
-
GM901 Carbon Monoxide Gas Analyzers
12 Páginas
-
GM35 In-Situ IR Gas Analyzer
16 Páginas
-
WT100-2 with background suppression
46 Páginas
-
Encoders
788 Páginas
-
Opto Electronic Protective Devices
712 Páginas
-
TRANSIC100LP Laser Oxygen Transmitter
20 Páginas
-
MCS300P Multicomponent Analysis System
12 Páginas
-
DBS36/DBS50 Core Incremental Encoders
44 Páginas
-
MERCEM300Z Mercury Monitoring System
12 Páginas
-
WT100-2 energetic
47 Páginas
-
VPS Pro Profiling systems
20 Páginas
-
Photoelectric Sensors
949 Páginas
-
G6 - Global Sensor
20 Páginas
-
Hand-Held Scanners IDMx
48 Páginas