DEKAL LOAD BANKS PORTABLE RESISTIVE 28.5 V DC LOAD BANKS - DIGITAL WiFi & USB SPECIFICALLY DESIGNED RUGGED UNITS USED FOR THE TESTING AND SERVICING OF 28.5 V DC GPUs TECHNICAL SPECIFICATION VOLTAGE [V] LOAD REGIME OPTIONS [A] LOAD TEST PROCEDURE TYPE LOAD TEST SPECIFICATION AT 28.5 V DC [DECREASING - ESS] SEQUENCE OF 6 STEPS ENGINE START SIMULATION Step 2: Step 3: Step 4: Step 5: Step 6: [DECREASING ESS - SELECTED MANUALLY] FORCED AIR COOLING [m3/min & CFM] AIRCRAFT ENGINE START SIMULATION (ESS) in duration of 35 seconds DECREASING LOAD TEST SPECIFICATION AT 28.5 V DC [CONTINUOUS - SELECTED MANUALLY] 1 second 3 seconds 10 seconds 20 seconds 30 seconds 35 seconds 300 A CONTINUOUS LOAD 600 A CONTINUOUS LOAD SEQUENCE OF 6 STEPS ENGINE START SIMULATION Step 1: 2000 A for Step 2: 1700 A for Step 3: 1200 A for Step 4: 1000 A for Step 5: 700 A for Step 6: 400 A for SEQUENCE OF 6 STEPS ENGINE START SIMULATION Step 1: 2500 A for Step 2: 1900 A for Step 3: 1300 A for Step 4: 1000 A for Step 5: 700 A for Step 6: 400 A for 1 second 3 seconds 10 seconds 20 seconds 30 seconds 35 seconds 1 second 3 seconds 10 seconds 20 seconds 30 seconds 35 seconds 300 A CONTINUOUS LOAD 600 A CONTINUOUS LOAD MEASUREMENTS & INDICATIONS DIGITAL POWER METER PARAMETERS WiFi & USB INTERFACE SPECIFICATIONS 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % FS + 2C; DISPLAYED: V / A / kW WiFi NETWORK OR USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE LIGHT INDICATION GPU TESTING PROCEDURE AND ENGINE DECARBONISING PROPOSAL(*) 28.5 V DC POWER INDICATION, FAILURE INDICATOR *LOAD 300 A for *LOAD 300 A or 600 A 30 / 15 minutes ESS in 6 STEPS 100%  0% 35 seconds *LOAD 300 A 30 minutes or ESS in 6 STEPS 100%  0% 35 seconds NOISE LEVEL [dB] AT DISTANCE [m/Ft] DIMENSIONS & WEIGHT LOAD BANK SIZE [L x W x H] mm / Kg LOAD BANK SIZE [L x W x H] In / Lbs TRANSPORT CASING [L x W x H] mm / Kg TRANSPORT CASING [L x W x H] In / Lbs LOAD BANK PAINTING / TRANSPORT CASING POWDER COATING FINE STRUCTURE 71319 IGP, SWISS QUALITY / HIGH GRADE ALUMINUM Including transport carrying case per unit / All specifications are subject to change without further

Abrir o catálogo na página 1
DEKAL 28 VDC Digital Load Bank brochure - 2

DEKAL LOAD BANKS ADVANTAGES OF DEKAL LOAD BANKS  Simple operation suitable for non-trained operators Silent operations < 70 dB(A) at the distance of 7m / 23Ft Suitable for workshop and/or airside operation Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF Transport casing with pull up handle as standard for each load bank Free DEKAL licensed software application & proper drivers included All measurements possible to archive & printout, including diagram graphics Effective way of monitoring and displaying measurement data High instrument indication accuracy Triple...

Abrir o catálogo na página 2

Todos os catálogos e folhetos técnicos LPA CONNECTION SYSTEMS LTD