
Excertos do catálogo

GRAVITY SPRAYGUNS SERIES USE & MAINTENANCE INSTRUCTION MANUAL EN
Abrir o catálogo na página 1
W-400 W-300 High T.E.C. W-300 |Classic Plus Series | &LPH-400 (LVLP) LPH-300 (LVLP) TECHNICAL DATA Fluid Nozzle Size Classic Plus Fluid Needle Mark
Abrir o catálogo na página 2
W-400 W-300 Plus T.E.C. | LPH-300 (LVLP W-300 | Classic High Series & LPH-400 (LVLP)) Before use, adjustment or maintenance, it is important to read this instruction manual very carefully. This manual must be stored in a safe place for any future reference. This ANEST IWATA spray guns kit complies to ATEX regulations ATEX 2014/34/EU. Protection level: II 2 G X Suitable for using Zones 1 and 2. X marking: Any static electricity discharged from the spray gun is to be diverted to the ground via the conductive air hose as stipulated. ALWAYS observe WARNINGS and CAUTIONS in this instruction...
Abrir o catálogo na página 3
W-400 W-300 High T.E.C. W-300 | Classic Plus Series |&LPH-400 (LVLP) LPH-300 (LVLP) 5. MAINTENANCE AND INSPECTION CAUTION Before carrying out maintenance and inspection ALWAYS observe warning indications. - Never use spare parts that are not Anest Iwata originals. - Never damage fluid nozzle tip, fluid needle or air cap holes. - Never immerse the spray gun completely in liquids such as thinner. 5.1 MANUAL CLEANING PROCEDURE The fluid passages of the gun, must be cleaned thoroughly after each use, especially after use with bi-component paints. Incomplete cleaning can cause defective pattern...
Abrir o catálogo na página 4
W-400 Classic Plus Series | LPH-400 (LVLP W-300 | W-300 High T.E.C. & LPH-300 (LVLP)) 6. TROUBLESHOOTING 7. SPARE PARTS LIST - Tip hole of nozzle obstructed. Check and clean. - Paint filter obstructed. Check and clean. - Fluid adj. knob (12) closed. Check and adjust. - Non drip obstructed. Check and clean. INTERMITTENT SPRAY PATTERN - Air escapes from fluid nozzle Check , clean & replace if - Air escapes from fluid needle Tighten. - Air escapes from cup joint. Tighten. - Dirt inside air cap (1). Clean. DEFECTIVE SPRAY PATTERN - Dirty nozzle (2-1) or air cap (1). Clean carefully. - Nozzle...
Abrir o catálogo na página 5
W-400 W-300 High T.E.C. W-300 | Classic Plus Series |& LPH-400 (LVLP) LPH-300 (LVLP) Prima di procedere all’installazione, alla messa in funzione, alla regolazione o alle operazioni di manutenzione, leggere attentamente il presente manuale d’istruzione, che deve essere conservato per ogni futuro riferimento. La pistola ANEST IWATA per verniciatura è in conformità alla normativa ATEX 2014/34/EU. Livello di protezione: categoria II 2G X adatto per uso in Zone 1 e 2. Marchiatura X: L’elettricità statica deve essere scaricata dalla pistola e condotta a terra attraverso la tubazione conduttiva...
Abrir o catálogo na página 6
W-400 Classic Plus Series | LPH-400 (LVLP W-300 | W-300 High T.E.C. & LPH-300 (LVLP) ) 5. MANUTENZIONE ED ISPEZIONE Prima di procedere a qualsiasi operazione d’ispezione e manuten- zione, leggere sempre ed osservare scrupolosamente tutte le indi cazioni sulle AVVERTENZE di SICUREZZA. - Mai utilizzare altri componenti o parti di ricambio che non siano origina- li ANEST IWATA. - Mai danneggiare i fori dell’ugello aria, dell’ugello materiale e l’estremità dell’astina. - Mai immergere completamente la pistola nei liquidi come solvente. 5.1 PROCEDURA PER LA PULIZIA MANUALE I passaggi del...
Abrir o catálogo na página 7
W-400 W-300 High T.E.C. W-300 | Classic Plus Series |& LPH-400 (LVLP) LPH-300 (LVLP) 6. PROBLEMI, CAUSE E RIMEDI 7. ELENCO PARTI DI RICAMBIO MANCATA FUORIUSCITA DI VERNICE - Regolazione materiale (12) Verificare e regolare. non sufficientemente aperta. - Foro ugello materiale (2-1) Verificare e pulire. ostruito. - Filtro vernice ostruito. Verificare e pulire. - Antigoccia ostruito. Verificare e pulire. ATOMIZZAZIONE AD INTERMITTENZA - Trafilamento d’aria dall’ugello Verificare, pulire e materiale (2-1). sostituire se necessario. - Trafilamento d’aria dalla guar- Stringere. nizione astina...
Abrir o catálogo na página 8
W-400 Classic Plus Series | LPH-400 (LVLP W-300 | W-300 High T.E.C. & LPH-300 (LVLP) ) Avant toute utilisation, tout réglage ou toute opération d’entretien, lire attentivement ce manuel d’instruction. Conserver ce manuel en lieu sûr pour pouvoir le consulter ultérieurement. EMPLOI ABUSIF 1. Ne jamais diriger le pistolet sur des personnes ou des animaux. 2. Ne jamais dépasser la pression ou la température maximale d’emploi. Ce kit de pistolet de pulvérisation ANEST IWATA est conforme aux normes ATEX 2014/34/EU. Concernant le niveau de protection: II 2G X adapté aux zones 1 et 2. Marque X:...
Abrir o catálogo na página 9
W-400 W-300 High T.E.C. W-300 | Classic Plus Series |&LPH-400 (LVLP) LPH-300 (LVLP) ATTENTION Avant de commencer toute opération d’inspection, lire et observer scrupuleusement toutes les indications concernant les AVERTISSEMENTS DE SÉCURITÉ. Ne jamais utiliser d’autres composants ou des pièces de rechange non originales ANEST IWATA. Ne jamais endommager les trous du chapeau, de la buse et de l’extrémité de l’aiguille. Ne jamais immerger complètement le pistolet dans des liquides tels que du solvant. 5.1 PROCEDURE DE NETTOYAGE MANUEL En particulier, nettoyer complètement et soigneusement les...
Abrir o catálogo na página 10
W-400 Classic Plus Series | LPH-400 (LVLP W-300 | W-300 High T.E.C. & LPH-300 (LVLP)) 6. PROBLEMES, CAUSES ET REMEDES 7. LISTE DES PIÈCES DE RECHANGE ABSENCE DE SORTIE DE PEINTURE - Réglage produit (12) Vérifier et régler. pas assez ouvert. - Trou buse produit (2-1) Vérifier et nettoyer. bouché. - Filtre peinture encrassé. Vérifier et nettoyer. - Antigoutte bouché. Vérifier et nettoyer. ATOMISATION PAR INTERMITTENCE - Fuite d’air de la buse (2-1). Vérifier, nettoyer et remplacer le cas échéant. - Fuite d’air du presse étoupe Serrer. (21). - Fuite d’air du raccord godet. Serrer. - Résidus de...
Abrir o catálogo na página 11Todos os catálogos e folhetos técnicos ANEST-IWATA FRANCE
-
DPS series
126 Páginas
-
PET-N series
27 Páginas
-
TOF-5B/TOF-6B
16 Páginas
-
WRA-101
4 Páginas
-
WA-M 220
32 Páginas
-
ws 400/ls 400
24 Páginas
-
EXTERNAL CHARGE
6 Páginas
-
W300 WB Retouch Spray Gun
1 Páginas
-
W200 Manual Spray Gun
1 Páginas
-
LPH 80
1 Páginas
-
W400 WBX
1 Páginas