YAK

YAK

YAK

Product catalog summary
Specifications:
- Customer: 32,385
- Measurement Accuracy: Not specified
- Date: 10/04/15
- Temperature: 20.5°C
- Humidity: 45.6%
- Inspectors: Not specified
Procedures:
- Chart starts at 10 daN (100.0 N)
- Limit value: 120 daN (7232.4 N including Measurement Uncertainty)
- Load factor: 6.0 g, Limit: 10.0 seconds
- Rating unit: 1000 N
Norms:
- Description/Norm: 20.1 seconds
- Measurement time: 0.0 seconds (-1 second), 37.8 seconds (+1 second)
Results:
- Maximum tensile load: 14216 N
- Comment: Passed
- Overstepping the limit value for a time: Not specified
Graph Analysis:
- The graph shows the force (N) over time (seconds) with a maximum tensile load reaching 14216 N.
Inspection Report:
- Reference: PrüfnummerZ:\SPEC-TEC-IMBRAGATURE\CRASH TEST\ARCHIVIO FILE TEST DINAMOMETRO txt\0104.txt
- LTF 91/09
See more

Catalog excerpts

YAK-1

Z:\SPEC-TEC-IMBRAGATURE\CRASH TEST\ARCHIVIO FILE TEST DINAMOMETRO t Inspection Report Article Customer Date Temp. C°/ humidity Inspectors - No. Chart start at [N] Limit value [N] Loadfactor Lv [g] rating unit (InpFile) Description/Norm Results Overstepping the limit value for a time of Chart start at Chart end at Maxima > Fp Maximum tensile load Comment Sek. Messzeit (- 1 Sek.) Messzeit (+ 1 Sek.) N passed