LDT/N

LDT/N

LDT/N

Product catalog summary
Overview:
The LDT/N Aircraft Oxygen Distributor is designed to fill aircraft installations with gaseous oxygen. It is mounted on a low chassis and includes a power generator, a bank of eight cylinders for compressed oxygen, a compressor, and an oxygen system. The compressor is powered by an electric engine driven by the power generator. The distributor operates on a 12 V battery system and is suitable for air transport onboard tactical transport aircraft like the CASA C-295 M. It can be towed on various surfaces, including hardened and unhardened roads.
Components and Functionality:
  • The main body is enclosed and comprises subassemblies necessary for oxygen compression, storage, purification, and supply.
  • The oxygen installation allows for multiple operations, including filling gas cylinders from external sources with or without the compressor, supplying oxygen from gas cylinders, and transferring oxygen between cylinder banks.
Operating Conditions:
  • Temperature range: -30°C to +55°C
  • Maximum relative humidity: 98% at +25°C
Oxygen Installation Parameters:
  • Type of gas: Gaseous oxygen for breathing, compliant with PN-93/L-01267
  • Dew-point saturation temperature at 0.1 MPa: No more than -55°C
  • Oxygen reserve at 15 MPa: 50 m³
  • Maximum pressure: 16.5 MPa
  • Safety valve opening pressure: 17.0 MPa
  • Gas cylinder filling pressure: 20 MPa
  • Compressor operating time: At least 4 hours
Output Installation Parameters:
  • Output oxygen pressure: 15 MPa and 3 MPa
  • Maximum output oxygen temperature: +70°C
  • Efficiency at ambient +20°C and suction line pressure no less than 12 MPa: 85 m³/h
Dimensions and Weight:
  • Length with tow bar: 5580 mm
  • Length without tow bar: 3700 mm
  • Width: 1780 mm
  • Height: 1850 mm
  • Weight with full tank and cylinders: 3300 kg
Contact Information:
WOJSKOWE CENTRALNE BIURO KONSTRUKCYJNO - TECHNOLOGICZNE S.A., 00-908 WARSZAWA, ul. Gen. Sylwestra KALISKIEGO 2, POLAND. Website: www.wcbkt.pl, Email: [email protected], Tel: +48 22 683-94-91, Fax: +48 22 666 81 62, +48 22 683 72 14
See more

Catalog excerpts

LDT/N-1

WOJSKOWE CENTRALNE BIURO KONSTRUKCYJNO - TECHNOLOGICZNE S.A. 00-908 WARSZAWA ul. Gen. Sylwestra KALISKIEGO 2 POLAND Tel. +48 22 683-94-91; Fax +48 22 666 81 62, +48 22 683 72 14 http://www.wcbkt.pl; e-mail: [email protected] LDT/N Aircraft Oxygen Distributor mounted on a low chassis is designed to fill aircraft installation with gaseous oxygen. LDT/N consists of: • enclosed main body comprising subassemblies and units needed for the process of oxygen compression, storage, purification and supply. The main body includes: power generator, bank of eight cylinders for compressed oxygen, compressor and oxygen system. The compressor is driven by an electric engine driven from power generator. The distributor’s wiring system operates from 12 V from battery. The oxygen installation enables: • filling the distributor's gas cylinders from an external source of oxygen without using the compressor (for example from the ground support oxygen gasificator LGT/N), • filling the distributor's gas cylinders from an external source of oxygen using the compressor (for example from gas cylinders), • supplying oxygen from gas cylinders without using the compressor, • supplying oxygen from gas cylinders using the compressor, • pumping over oxygen from one bank of gas cylinders to another. LDT/N is designed for air transport onboard the CASA C-295 M or other tactical transport aircraft. Unit can be towed on airfield taxi ways and on roads of hardened or unhardened surface. LDT/N distributor can be used in the open terrain under the following operating conditions: • operating temperature range: -30°C+ +55°C • max operating relative humidity: 98% at temp. +25°C

 Open the catalog to page 1
LDT/N-2

WOJSKOWE CENTRALNE BIURO KONSTRUKCYJNO - TECHNOLOGICZNE S.A. 00-908 WARSZAWA ul. Gen. Sylwestra KALISKIEGO 2 POLAND Tel. +48 22 683-94-91; Fax +48 22 666 81 62, +48 22 683 72 14 http://www.wcbkt.pl; e-mail: [email protected] • type of gas: gaseous oxygen for breathing in compliance with • saturation temperature ("dew-point") with 0,1 MPa pressure (760 Hg) • oxygen reserve in gas cylinders bank at pressure of 15MPa (0,1 MPa) • max. pressure of oxygen instalation • safety valve openning pressure • gas cyllinder filling pressure • compressor total operating time Oxygen installation parameters:...

 Open the catalog to page 2

All WCBKT S.A. catalogs and technical brochures

  1. BESKID-2M/Z

    2  Pages

  2. BESKID-2M/K

    2  Pages

  3. STELLA - 100

    2  Pages

  4. Dehumidifiers

    2  Pages

  5. LSP/N

    2  Pages

  6. LGT/N

    2  Pages

  7. LGA/N

    2  Pages

  8. LDP/N

    2  Pages

  9. LDA/N

    2  Pages

  10. LZH/M

    2  Pages

  11. STELLA

    2  Pages

  12. ATHOS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.