Catalog excerpts
V19800 2-Way Normally Open or Normally Closed Fuel Shut-Off Solenoid Valve Valcor Aerospace - 2-Way Direct Acting Shut-Off Valve This Valcor valve is a two way, (normally closed or normally open), solenoid-operated shut-off valve used to control the flow of aviation fuels, non-corrosive gases, or nonaeromatic hydraulic fluids. The V19800 is designed for face seal mounting, allowing it to be mounted independently or on a manifold. This design will minimize the size and space needed in your system for these solenoid valves. The valves also utilize Valcor’s floating seal design for tight sealing, minimal wear, and particulate resistance. This type of valve is used on many APUs and engines. APUs can use multiple valves manifolded together, for engine starting, running, and purging the fuel manifolds. These valves can also be used as firewall shut-off, deicing, and pilot valves for larger valves on commercial or military aircraft. • Available in Normally Open and Normally Closed • Temperature: -65°F to +250°F • Operating Pressure: 0-1200 PSIG • Proof Pressure: 1800 PSIG Max • Burst Pressure: 2400 PSIG Max • Flow: ESEO wup to 0.185”, Cd=0.65 • Low Current • 1.3 amps @ 30 vdc @ 72°F (47 Ohms) • Lightweight: 0.75 to 1.5 lbs approx. • Low internal leakage: Liquid—0.5 cc/hr. Gas—15 scc/minute. • Low external leakage: zero over range of 0 to 1500 PSIG • Carbon floating seal: Tight leakage, reduce wear & friction • Voltage:18 to 30 vdc • No minimum operating pressure is required for tight sealing © 2018 VALCOR ENGINEERING CORPORATION
Open the catalog to page 1SOLENOID VALVE SERIES V19800 Specifications Operating Pressure and Flow Ranges Equiv. Sharp Edged Orifice CD =.65 NORMALLY CLOSED CONFIGURATION Operating Pressure (PSIG) 30 OHM Coil Ambient Temp. NORMALLY OPEN CONFIGURATION 0-1000 0-600 0-90 These ratings are based on using JP4 Aviation Fuel. For higher temperatures, the pressure rating must be reduced. The following table approximates the derating required. Temperature Derating Factor Electrical Data Voltage Duty 18 to 30 VDC 30 OHM Coil, Continuous or Intermittent 47 OHM Coil, Continuous (Depends on application, cooling effect of fluid,...
Open the catalog to page 2All VALCOR ENGINEERING CORPORATION catalogs and technical brochures
-
V522-7010
1 Pages
-
Aircraft Relief Valves
2 Pages
-
SV525
2 Pages
-
SV515
2 Pages
-
70900-65 Balanced Poppet
2 Pages
-
70900-98 Direct Acting
2 Pages
-
Aircraft Pressure Regulators
2 Pages
-
Hydraulic Accumulators
2 Pages
-
SV91
2 Pages
-
SV97
2 Pages
-
SV95
2 Pages
-
V526G
2 Pages
-
V526P
2 Pages
-
V526D
2 Pages
-
V526B
2 Pages
-
V5000
2 Pages
-
SV61/62
2 Pages
-
SV11/12
2 Pages
-
V27200 - Miniaturized
2 Pages
-
V14500
2 Pages
-
V4700
2 Pages
-
V3400
2 Pages
-
V70900
2 Pages