Catalog excerpts
Specialty Heated and Water Systems Components Catalog Where ingenuity takes off™
Open the catalog to page 1System Components Heated Components Lavoratory Water Heater Potable Water System Controller Auxiliary Air Compressor System Hardware • Fill / Drain Valve • Motor Valves • Pressure Regulator • Vent Valves • Control Cable Heated Storage Tank with Blanket Heater • Level Sensors • Relief Valve Heated Drain Masts • Water Pumps • Check Valve Potable Water System Service Panel • Shower Heaters This document does not contain any export controlled techni
Open the catalog to page 2Category Water Storage Tanks 28 VDC Motorized Valves Manual Valves Control Cables and Gearboxes Miscellaneous Valves Freeze Protection Heaters Heated Hoses Service Panels Fill Caps and Adapters Pneumatic Components Water Pumps and Air Compressor Lavatory / Galley Water Heaters / Water System / Shower Heaters Heated Drain Masts Electronic Controllers Air Heaters Heated Floor Panels This document does not contain any export controlled technical data. Page 3
Open the catalog to page 3Water Storage Tanks UTC Aerospace Systems offers cylindrical or conformed titanium and stainless steel water tanks that have been sized for various flight requirements. Structural analysis and full qualification testing have been performed on each water tank design. Water tanks include ports for vent and relief valves. Numerous tanks include level sensing and optional heating. This document does not contain any export controlled technical data.
Open the catalog to page 4Water Storage Tanks Part Number This document does not contain any export controlled technical data.
Open the catalog to page 5This document does not contain any export controlled technical data. Pag
Open the catalog to page 628 VDC Motorized Valves UTC Aerospace Systems offers 28 VDC motorized stainless steel ball valves with low pressure drop levels. Pulse width modulation is available on selected models only. Full qualification testing has been performed on each motorized valve design. Position switches are used for fault detection and optional valve heaters are available on select models. This document does not contain any export controlled technical data.
Open the catalog to page 7Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 9
Open the catalog to page 8Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 10
Open the catalog to page 9Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 11
Open the catalog to page 10Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data.
Open the catalog to page 11Manual Valves UTC Aerospace Systems also offers manual or cable actuated valves for fill, drain and shut-off. This document does not contain any export controlled technical data.
Open the catalog to page 12Note: All are 300 series stainless steel and include mounting brackets. FILL MODE FLIGHT MODE PORTS A AND B = OPEN PORTS A AND C = OPEN PORTS D AND E = OPEN PORTS B. D AND £ = CLOSED PORT C = CLOSED DRAIN MODE PORTS B AND C= OPEN PORTS D AND E = OPEN PORT A = CLOSED This document does not contain any export controlled technical data. Page 15
Open the catalog to page 13Control Cables and Gear Boxes The Control Cable, Handle Assembly and Gearbox Assembly provide the mechanical means for opening the Potable Water System (PWS) tank fill valves. These components are typically accessed from the aircraft’s external service panel. To operate, the control cable handle is rotated 90° counterclockwise from its detented closed position, and the handle is then pulled, opening the fill/overflow valve. After the PWS is filled, the handle is pushed in to the closed position and turned 90° clockwise to lock in place. This document does not contain any export controlled...
Open the catalog to page 14This document does not contain any export controlled technical data. Page 17
Open the catalog to page 15Miscellaneous Valves Vent Valves, Drain Check Valves, Float Check Valves Vent and check valves are available to allow proper system drainage, isolation and prevent a backflow condition. This document does not contain any export controlled technical data.
Open the catalog to page 16This document does not contain any export controlled technical data. Page 19
Open the catalog to page 17Freeze Protection Heaters Silicone, Kapton and Innerline UTC Aerospace Systems heaters offer freeze protection for the water system throughout the aircraft. Several heaters offer integrated electronic thermostats with fault sensing (ESTAT™ Controller). This document does not contain any export controlled technical data.
Open the catalog to page 18This document does not contain any export controlled technical data. Page 21
Open the catalog to page 19Heated Hoses UTC Aerospace Systems heated hoses offer freeze protection for potable water systems. The heaters are controlled by an electronic thermostat (ESTAT™ Controller) with fault sensing which reduces size and weight while offering effective temperature control. This document does not contain any export controlled technical data.
Open the catalog to page 20Part-number series denotes multiple part numbers on the same drawing This document does not contain any export controlled technical data. Page 23
Open the catalog to page 21Service Panels External or Internal Service Panels have capabilities for pressurized fill, mode selection, backup control, internal and external level indication. This document does not contain any export controlled technical data.
Open the catalog to page 22Part-number series denotes multiple part numbers on the same drawing This document does not contain any export controlled technical data. Page 25
Open the catalog to page 23Fill Caps and Adaptors The Fill Adapter and Cap Assemblies are installed on the aircraft’s external service panel and provide a means for attaching the potable water service truck to the aircraft’s potable water storage tank. The Fill Adapter is designed to mate with standard aircraft potable water service vehicles and is configured with an attached Cap Assembly that isolates the potable water system from outside contamination. This document does not contain any export controlled technical data.