Overview
UTC Aerospace Systems offers a comprehensive catalog of specialty heated and water systems components, including auxiliary air compressors, potable water system controllers, heated storage tanks, and various system hardware components such as valves, pumps, and sensors.
Water Storage Tanks
The catalog details cylindrical and conformal water tanks made from titanium and stainless steel, designed for different flight requirements. Key features include ports for vent and relief valves, level sensing, and optional heating. Specifications such as usable water capacity, maximum operating pressure, and material type are provided for each tank model.
28 VDC Motorized Valves
These stainless steel ball valves are designed with low pressure drop levels and optional pulse width modulation. They include features like position switches for fault detection and optional valve heaters. Specifications include the number of positions and ports, weight, fitting type, and special features like electrical position indication and manual override.
Manual Valves
Manual or cable actuated valves are available for fill, drain, and shut-off purposes. Specifications include the number of ports and positions, weight, and fitting type, along with special features like fill/drain/flight positions.
Control Cables and Gearboxes
These components facilitate the mechanical operation of potable water system tank fill valves. Specifications for various control cables and gearboxes include length, weight, and special features.
Miscellaneous Valves
The catalog includes vent and check valves designed for system drainage, isolation, and backflow prevention. Specifications such as material, operating pressure, and fitting type are provided for each valve.
Valves
The document lists different types of valves such as vent valves and float check valves, specifying their dimensions, weight, material (mostly 300 series stainless steel), and pressure ratings. These valves are designed to prevent backflow and ensure proper drainage.
Freeze Protection Heaters
Various heaters are described, including water tank heaters, check valve heaters, and pressure relief valve heaters. These heaters are made from materials like silicone and polyimide film, with power consumption ranging from 6.0W to 181.2W, and are designed to operate at 115 VAC with external temperature control or electronic thermostats.
Heated Hoses
The document details heated hoses that provide freeze protection for potable water systems. These hoses vary in length and power range, with features like electronic thermostats and fault monitoring. They are designed to operate at 115 VAC.
Service Panels
External and internal service panels are described, featuring capabilities for pressurized fill, mode selection, and level indication. They are made from materials like aluminum and stainless steel, with features such as push buttons and LED indicators.
Fill Caps and Adaptors
These components are used for attaching potable water service trucks to aircraft storage tanks. They are made from 300 series stainless steel and designed to prevent contamination.
Pneumatic Components
Includes flow restrictors, air filters, check valves, pressure regulators, and pressure relief valves. These components are used in air pressurized potable water systems to maintain constant water flow rates and provide backflow protection.
Water Pump and Air Compressor
The water pump is made from stainless steel with a magnetic coupling and brushless motor, while the air compressor has an aluminum housing. Both are designed for specific flow rates and pressures, with features like thermal protection and adjustable speeds.
Lavatory/Galley Water Heaters
Various water heaters are described, offering options for different capacities and temperature settings. They include features like electronic temperature selection, overheating protection, and are made from 300 series stainless steel.
Heated Drain Masts
UTC Aerospace Systems provides heated drain masts made from aluminum or composite materials. These masts feature corrosion-resistant stainless steel or copper tubes and a coaxial tube heater to prevent ice formation. They offer dual-mode operation with full power in flight and low power on the ground. Over-temperature thermostats and sensors ensure ice-free operation and prevent overheating.
Specifications
The document lists various part numbers with details such as dimensions, weight, material, inlet port specifications, power supply, voltage, temperature control, and special features.
Electronic Controllers
UTC Aerospace Systems offers centralized controllers for zone control of heated lines, tanks, valves, and other components of the potable water system. These controllers feature integrated display panels, circuit breakers, fuses, and fault sensing. They use ARINC 429 bus communication for control and monitoring.
Air Heaters
Supplemental air heaters are used to warm cabin air in specific areas like exit doors and cargo holds. They can be controlled via internal thermostats or electronic controls. Closed-loop heating systems are available, featuring microprocessor-based controllers and air temperature sensors.
Air Temperature Sensors
Details of air temperature sensors include part numbers, descriptions, dimensions, weight, material, resistance, and features.
Heated Floor Panels
Heated floor panels are installed in various aircraft to ensure passenger and crew comfort. They consist of titanium or composite skins and feature low profiles, hermetic sealing, redundant over-temperature protection, and rapid heat transfer.
Contact Information
For additional information, contact Goodrich Corporation, a UTC Aerospace Systems company, at 1555 Corporate Woods Parkway, Uniontown, OH 44685, U.S.A. Phone: +1 800 DE-ICERS (800 334 2377), Fax: +1 330 374 2290, Email: [email protected].
See more

Catalog excerpts

Specialty Heated and  Water Systems Components  Catalog-1

Specialty Heated and Water Systems Components Catalog Where ingenuity takes off™

 Open the catalog to page 1
Specialty Heated and  Water Systems Components  Catalog-2

System Components Heated Components Lavoratory Water Heater Potable Water System Controller Auxiliary Air Compressor System Hardware • Fill / Drain Valve • Motor Valves • Pressure Regulator • Vent Valves • Control Cable Heated Storage Tank with Blanket Heater • Level Sensors • Relief Valve Heated Drain Masts • Water Pumps • Check Valve Potable Water System Service Panel • Shower Heaters This document does not contain any export controlled techni

 Open the catalog to page 2
Specialty Heated and  Water Systems Components  Catalog-3

Category Water Storage Tanks 28 VDC Motorized Valves Manual Valves Control Cables and Gearboxes Miscellaneous Valves Freeze Protection Heaters Heated Hoses Service Panels Fill Caps and Adapters Pneumatic Components Water Pumps and Air Compressor Lavatory / Galley Water Heaters / Water System / Shower Heaters Heated Drain Masts Electronic Controllers Air Heaters Heated Floor Panels This document does not contain any export controlled technical data. Page 3

 Open the catalog to page 3
Specialty Heated and  Water Systems Components  Catalog-4

Water Storage Tanks UTC Aerospace Systems offers cylindrical or conformed titanium and stainless steel water tanks that have been sized for various flight requirements. Structural analysis and full qualification testing have been performed on each water tank design. Water tanks include ports for vent and relief valves. Numerous tanks include level sensing and optional heating. This document does not contain any export controlled technical data.

 Open the catalog to page 4
Specialty Heated and  Water Systems Components  Catalog-5

Water Storage Tanks Part Number This document does not contain any export controlled technical data.

 Open the catalog to page 5
Specialty Heated and  Water Systems Components  Catalog-6

This document does not contain any export controlled technical data. Pag

 Open the catalog to page 6
Specialty Heated and  Water Systems Components  Catalog-7

28 VDC Motorized Valves UTC Aerospace Systems offers 28 VDC motorized stainless steel ball valves with low pressure drop levels. Pulse width modulation is available on selected models only. Full qualification testing has been performed on each motorized valve design. Position switches are used for fault detection and optional valve heaters are available on select models. This document does not contain any export controlled technical data.

 Open the catalog to page 7
Specialty Heated and  Water Systems Components  Catalog-8

Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 9

 Open the catalog to page 8
Specialty Heated and  Water Systems Components  Catalog-9

Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 10

 Open the catalog to page 9
Specialty Heated and  Water Systems Components  Catalog-10

Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data. Page 11

 Open the catalog to page 10
Specialty Heated and  Water Systems Components  Catalog-11

Note: All are 300 series stainless steel, 11 watts, and include mounting brackets. This document does not contain any export controlled technical data.

 Open the catalog to page 11
Specialty Heated and  Water Systems Components  Catalog-12

Manual Valves UTC Aerospace Systems also offers manual or cable actuated valves for fill, drain and shut-off. This document does not contain any export controlled technical data.

 Open the catalog to page 12
Specialty Heated and  Water Systems Components  Catalog-13

Note: All are 300 series stainless steel and include mounting brackets. FILL MODE FLIGHT MODE PORTS A AND B = OPEN PORTS A AND C = OPEN PORTS D AND E = OPEN PORTS B. D AND £ = CLOSED PORT C = CLOSED DRAIN MODE PORTS B AND C= OPEN PORTS D AND E = OPEN PORT A = CLOSED This document does not contain any export controlled technical data. Page 15

 Open the catalog to page 13
Specialty Heated and  Water Systems Components  Catalog-14

Control Cables and Gear Boxes The Control Cable, Handle Assembly and Gearbox Assembly provide the mechanical means for opening the Potable Water System (PWS) tank fill valves. These components are typically accessed from the aircraft’s external service panel. To operate, the control cable handle is rotated 90° counterclockwise from its detented closed position, and the handle is then pulled, opening the fill/overflow valve. After the PWS is filled, the handle is pushed in to the closed position and turned 90° clockwise to lock in place. This document does not contain any export controlled technical...

 Open the catalog to page 14
Specialty Heated and  Water Systems Components  Catalog-15

This document does not contain any export controlled technical data. Page 17

 Open the catalog to page 15
Specialty Heated and  Water Systems Components  Catalog-16

Miscellaneous Valves Vent Valves, Drain Check Valves, Float Check Valves Vent and check valves are available to allow proper system drainage, isolation and prevent a backflow condition. This document does not contain any export controlled technical data.

 Open the catalog to page 16
Specialty Heated and  Water Systems Components  Catalog-17

This document does not contain any export controlled technical data. Page 19

 Open the catalog to page 17
Specialty Heated and  Water Systems Components  Catalog-18

Freeze Protection Heaters Silicone, Kapton and Innerline UTC Aerospace Systems heaters offer freeze protection for the water system throughout the aircraft. Several heaters offer integrated electronic thermostats with fault sensing (ESTAT™ Controller). This document does not contain any export controlled technical data.

 Open the catalog to page 18
Specialty Heated and  Water Systems Components  Catalog-19

This document does not contain any export controlled technical data. Page 21

 Open the catalog to page 19
Specialty Heated and  Water Systems Components  Catalog-20

Heated Hoses UTC Aerospace Systems heated hoses offer freeze protection for potable water systems. The heaters are controlled by an electronic thermostat (ESTAT™ Controller) with fault sensing which reduces size and weight while offering effective temperature control. This document does not contain any export controlled technical data.

 Open the catalog to page 20
Specialty Heated and  Water Systems Components  Catalog-21

Part-number series denotes multiple part numbers on the same drawing This document does not contain any export controlled technical data. Page 23

 Open the catalog to page 21
Specialty Heated and  Water Systems Components  Catalog-22

Service Panels External or Internal Service Panels have capabilities for pressurized fill, mode selection, backup control, internal and external level indication. This document does not contain any export controlled technical data.

 Open the catalog to page 22
Specialty Heated and  Water Systems Components  Catalog-23

Part-number series denotes multiple part numbers on the same drawing This document does not contain any export controlled technical data. Page 25

 Open the catalog to page 23
Specialty Heated and  Water Systems Components  Catalog-24

Fill Caps and Adaptors The Fill Adapter and Cap Assemblies are installed on the aircraft’s external service panel and provide a means for attaching the potable water service truck to the aircraft’s potable water storage tank. The Fill Adapter is designed to mate with standard aircraft potable water service vehicles and is configured with an attached Cap Assembly that isolates the potable water system from outside contamination. This document does not contain any export controlled technical data.

 Open the catalog to page 24
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.