Data sheet TMI-Orion VACQ uFlat Ultra-flat data logger for measurement of temperature in 3 points in processes where clearance is an issue. VACQ uFlat is an ultra-flat data logger (7.5 mm high) designed for temperature measurement in drying and cooking processes of very flat products, such as boards or panels, or in ovens with reduced clearance. VACQ uFlat must be protected by a thermal shield when temperature exceeds +125°C. Metrology Operating range Without thermal shield : from 0°C to 125°C For temperatures over 125°C, a thermal shield is necessary. Measurement range Internal reference channel calibration uncertainty* Each logger can be calibrated and adjusted at the temperature points corresponding to the user’s needs, within the thermocouple range. *The specified uncertainties correspond to two standard deviations. The uncertainties are calculated taking into account the various significant error sources, including the calibration probes, the equipment, the environmental conditions, the influence of the logger, repeatability, etc… Start set up: immediate or delayed Time stamped measurement data TMI-Orion VACQ uFlat Battery level alert with Qlever software TO/DS
Open the catalog to page 1Technical specifications Material Logger body: Anodized aluminum 3 connected thermocouple elements 1 platinum sensor as reference channel for cold junction and internal temperature of the box Temperature sensor Thermocouples : type K (full scale 1300°C) or type T (full scale 400°C) Memory capacity 65 100 acquisitions divided by number of measurement channels Acquisition rate Programmable: minimum 3 acquisitions per second, maximum 59 minutes and 59 seconds Program duration Programmable: days, hours, minutes Programmable start: by date, hour, minute User replaceable battery pack VACQ uFlat...
Open the catalog to page 2Software and related products VACQ uFlat is used with Qlever software platform. Qlever software platform: data acquisition, management and visualization of data from TMI-Orion data loggers. Qlever is installed on a PC and operates under Windows® Vista/7/8/10. Data transmission and visualization are done after the industrial process. Deliverables The VACQ uFlat solution usually includes the following items: • The VACQ uFlat data logger with a battery pack • The VACQ uFlat calibration certificate The VACQ uFlat configuration and calibration file Qlever software platform (to be ordered...
Open the catalog to page 3All TMI-ORION & TMI-USA catalogs and technical brochures
-
QLEVER Ceramics
3 Pages
-
NanoVACQ xFlat Temperature
3 Pages
-
PicoVACQ Thermocouple
3 Pages
-
NanoVACQ Flat
3 Pages
-
NanoVACQ HT FullRadio
4 Pages
-
NanoVACQ HT
4 Pages
-
NanoVACQ Ex
3 Pages
-
NanoVACD AD
3 Pages
-
MiniVACQ
2 Pages
-
High-T-Dry
3 Pages
-
NanoVACQ Deformation
1 Pages
-
CeriDry FullRadio
3 Pages
-
CeriDry
2 Pages