ADC-2522

ADC-2522

ADC-2522

Product catalog summary
Overview: The TestVonics™ ADC-2522 Air Data Calibrator is a high-precision air data management system designed for controlling and measuring altitude and airspeed pressures with exceptional accuracy. It is suitable for both commercial and military test applications and features compatibility with Honeywell Sperry ADT-222B via an IEEE-488 interface.
Key Features:
  • 10.4-inch LED backlit LCD touchscreen for direct control and intuitive operation.
  • Includes USB keyboard and mouse for additional input options.
  • Utilizes digiquartz transducers for high performance and accuracy maintenance for up to one year.
  • Graphical user interface allows easy mode switching and data display in tables or graphs.
  • Remote operation capability via RS-232 port and software upgradeability for future applications.
Protection and Safety:
  • Features input pressure regulation and over-limit protections.
  • Equipped with micro-porous filters, pressure relief valves, and a manual vent for safety.
  • Automated test routines can be created for efficiency and consistency.
Specifications:
  • Altitude Control Range: -2,000 to 99,000 feet with accuracy of 0.01% or ±0.003 inHg.
  • Airspeed Control Range: 0 to 1,050 Knots with accuracy of 0.01% ±0.008 inHg.
  • Interfaces: RS-232, USB, Ethernet, IEEE-488.2, VGA Output.
  • Power Requirements: 90-264 VAC, 45-440 Hz, 1 PH.
  • Dimensions/Weight: 19 x 10.5 x 20 inches, 36 lbs.
Optional Support Equipment: Includes high-performance pressure and oil-free vacuum sources for system integration.
Contact Information: TestVonics Incorporated, 375 Jaffrey Road, Peterborough, NH 03458. Phone: (603) 924-5922. Web: www.testvonics.com
See more

Catalog excerpts

ADC-2522-1

TestVonics Precision Calibrators ™ ADC-2522 Air Data Calibrator Plug and Play replacement for the Honeywell ADT-222B Brilliant, High Resolution LED Backlit 10.4” LCD Touchscreen Easy to use, intuitive and upgradable Graphical User Interface TestVonics Part Number P/N: 4047505-422 421 NSN: 4920-01-105-0016 ADC-2522 Air Data Calibrator TestVonics™ ADC-2522 Air Data Calibrator is a high accuracy air data management system. The calibrator is capable of controlling and measuring Altitude and Airspeed pressures to the highest degree of accuracy. The control and measurement range of the test system meets or exceeds most requirements for commercial and military test applications. The ADC-2522 features a plug-and-play Honeywell Sperry ADT-222B compatible IEEE-488 interface and protocol. Features The ADC-2522 features a brilliant 10.4-inch LED backlit LCD display. A resistive touchscreen allows the calibrator to be controlled directly from the front panel. An on-screen keyboard appears when operator input is needed. Additionally a USB keyboard and mouse is included as standard equipment with the calibrator. The calibrator uses 2 digiquartz transducers which provide unmatched performance. Corrections are done through software requiring no mechanical adjustments and are capable of holding accuracy for a period of one (1) year. Simple and Intuitive Interface The ADC-2522 software provides a familiar and intuitive graphical user interface. Modes of Operation are easily selected through tabs located along the top of the screen. The operator can easily switch between modes while testing without affecting operation. The calibrator measures and records readings, while displaying data as a table or graphically. All information is stored directly on the calibrator and reports can be printed. The ADC-2522 can be operated remotely using the RS-232 (serial) port on the rear panel. The operating platform allows the system to be upgraded for future test applications through software upgrades, standalone installer packages or customized software applications. Protection and Safety Features The ADC-2522 is designed with hardware and software features for maximum protection to the operator and unit under test (UUT). The calibrator features input pressure regulation, over-range, overlimit and over-pressurization protection. Micro-porous filters and screening prevent debris from contaminating the system. The calibrator is equipped with pressure relief valves to protect the pneumatic system components and the UUT from damage. In the event that the calibrator loses power, the manual vent can be used to safely vent both the test set and the UUT to ambient. The Test Program function allows the operator to create virtually unlimited test number of test routines for automated testing. These test routines save time and provide improved test consistency. Measure Mode Control Mode Leak Test Mode Test Program (Control) M

 Open the catalog to page 1
ADC-2522-2

ADC-2522 Air Data Calibrator Features Rear Panel 1. 10.4" LED Touchcscreen LCD 2. Manual Vent switch 3. Power Switch 4. Airspeed Pitot (Pt) Port 5. Altitude Static (Ps) Port 6. USB 2.0 Ports (x2) 7. RJ-45 Ethernet port Control Stability Touchscreen Display Yes Optional ADC-2522 Series Support Equipment TestVonics high performance pressure and oil-free vacuum sources provide easy system integration that are suitable for the ADC-2522 Series and a wide variety of other applications. Dimension / Weight 19 x 10.5 x 20 in (19-inch rackmount) / 36 lbs (17.24 kg) TestVonics Incorporated 375 Jaffrey...

 Open the catalog to page 2

All Testvonics catalogs and technical brochures