The system is designed for the control and monitoring of Sequential Flashing Lights (SFL_LED’s) and Runway Threshold Identification Lights (RTIL’s). It includes:
Performance metrics include minimum and average candela values, ensuring visibility and compliance with standards.
The system includes a Master Control Panel for managing the Sequential Flashing Light System and Runway Threshold Identification Lights, available in both elevated and inset configurations.
The system design includes various screens for operation and control, such as loading, configuration, service, diagnostic, main, and command screens.
SEQUENTIAL FLASHING LIGHT SYSTEM - LED RUNWAY THRESHOLD IDENTIFICATION LIGHTS - LED STM.400.SFL.01 • Elevated STM.400.SFL.02 • Inset STM.400.RTL.01 • Elevated STM.400.RTL.02 • Inset Related Standards and Compliances ICAO FAA IEC NATO Annex 14 Volume 1 EB-67D TS / EN 61827 STANAG 3316 Application The system control and monitoring of light chain (SFL_LED's) and threshold identification lights (RTIL's). System consist of : • 1 SFL Master Control unit (SFL Master Control) • Up to 30 flashing light units (SFL LED) • 2 threshold identification lights (RTIL's) Features • LED life up to 60000 hours. • Communication over Powerline or Twisted pairs. • Led and module failures are monitored instantly. • 7” LCD touch screen for local control on Master control unit. • OLED Display on every LED module PCB's. • Remote control by ALCMS systems with MODBUS RTU/TCP, CANBUS2.0B or any other communication protocols. • 1-2Hz flashing frequency. • 3 steps intencity control (%3-%10-%100). • Protection against high voltage and voltage peaks. • Protection against shocks from the ground line-lightnings. • Fully compatible with existing AFL infrastructure. • Software update via USB stick. Technical Specifications • Protection Degree for SFL LED Units : IP67 • Working Temperature - Master Control : -25C to +55C • Working Temperature - LED Units : -40C to +55C • Power Source : 220-230Vac / 50-60hz / 1L+N+E • Power Consumption : Led Units : 45VA Master Control : 25VA Total Max. : 1,5kVA • Safety Standarts for Internal Power Supplies : UL62368-1, TUV EN62368-1, EN60335-1, EN61558-1/-2-16,CCC GB4943.1, BSMI CNS14336-1, EAC TP TC 004, AS/NZS 60950.1(by CB)
Open the catalog to page 1SEQUENTIAL FLASHING LIGHT SYSTEM - LED RUNWAY THRESHOLD IDENTIFICATION LIGHTS - LED STM.400.SFL.01 STM.400.SFL.02 STM.400.RTL.01 STM.400.RTL.02 Elevated Inset Elevated Inset Operation / Control : 1 - System Loading Screen : System Design RTIL 01 Typical Installation RTIL 01
Open the catalog to page 22 Pages