General Overview:
The document provides technical specifications for the Hurricane, a modular multi-channel system designed for the measurement and analysis of sound and vibration. It is suitable for use in both mobile and stationary applications, particularly in the automotive industry, engineering services, and environmental protection.

Technical Specifications:
  • Input Channels: 1-16 channels with a resolution of 16-bit for time signals and 20-bit for level calculation. Real-time bandwidth is 20 kHz with a sampling rate of 51.2 kHz.
  • Noise and Distortion: THD+N > 80 dB, cross-talk attenuation > 80 dB, and noise levels < 1.4 µV (A).
  • Voltage and Filters: Max input voltage with ranges of ±0.1 V to ±10V, anti-aliasing filter, and various input filters including DC, AC, HP, and LP.
  • Output Channels: 1-8 channels with a sampling rate of 51.2 kHz and max output voltage of ±3.16 Vpeak.
  • Environmental Conditions: Operates within a temperature range of -10°C to +40°C and humidity of 30% to 90%.

Software and Features:
The system is compatible with SAMURAI software, offering a range of virtual measuring devices and analysis options:
  • Sound Level Meter: Class 1 SLM for simultaneous measurements with various frequency and time weightings.
  • Frequency Analyzer: Real-time 1/3 octave analysis and FFT analysis with adjustable averaging modes.
  • Reverberation Time Measurement: Measures reverberation time in 1/3 octaves with various excitation types.
  • Recommended Software Options: Includes post-processing, sound power measurement, automation, building acoustics, building vibration, fractional octaves, human vibration multi-analyzer, monitoring, multi-generator, NoiseCam, order tracking, transfer FRF, vibration meter, and remote client and TCP/IP interface.

Applications:
The Hurricane system is particularly suited for car manufacturers, design and development, quality assurance, and environmental and labor protection. It supports a wide range of sensors and is designed for dynamic signal measurement, making it ideal for vehicle and test stand applications.
See more

Catalog excerpts

HURRICANE-1

The following data refer to the 16-channel versions of Hurricane with LEM07 or BNC connectors based on up to 4x HARMONIE-PCI data acquisition cards. Customized versions on request possible. General technical specification of Hurricane Harmonie-PCI versions: - 4ch LEMO7 input connectors - 4ch BNC input connectors - 8ch DSUB input connectors Technical specifications Input channels 1-16: Resolution: Real-time bandwidth THD+N Cross-talk attenuation Noise Sampling rate Digital splitting factor Anti-aliasing filter Max input voltage Ranges Overload detection Phase mismatch Offset adjust Input filter Channel cascading for dynamic expansion Sensor power supply LEMO7 Sensor power supply BNC 16 bit in time signal 20 bit in level calculation 20 kHz > 80 dB > 80 dB < 1.4 mV (A) < 2.2 mV (lin. 20 Hz...20 kHz) 51.2 kHz 1/2/4/8... 1024 (via DSP) yes (0...22.4kHz) VPeak (overmodulation reserve 1dB) ±0.1 V, ±0.3 V, ±1.0 V, ±3.0 V, ±10V, indicator for out-of-band frequency < 0.1° at gain -20 dB (20 Hz ... 20 kHz) yes DC, AC 0.15 Hz, HP 10 Hz, LP 2 kHz channel 1-2, channel 3-4 ... Channels 15-16 microphone ±14 V, +200 V; ICP 2 mA ICP 2 mA Power supply: DC input AC adapter Back-up battery Intel dual Core embedded 2 GByte 256 Gbyte SSD 4x USB, LAN, 3x RS232, VGA, PS/2 passive cooling system (0 dB) 10 ... 33 VDC 1 15/230 VDC included 14.4 V Lilon V-Mount (optional) with external charger Weights and measures: Dimensions 240 x 230 x 115 mm3 Environmental conditions: Temperature range -10°C...+40°C Modular Multi-Channel System for Measurement and Analysis of Sound and Vibration SLOW channels: Resolution: Sampling rate Input voltage Input resistance via AUX (for LEMO7 version only) 12 bit total 50 Hz (100 Hz, 200 Hz) 0...15V for 5 channels 12 kW for channels 5-9 2.5 kW for channel 10 and 11 Output 1-8: Sampling rate Bandwidth Max. output voltage Attenuation Trigger/Tacho Input: via AUX (LEMO version) or BNC Input voltage min TTL, max +15 V Sound Level Meter type 1 according to IEC 61672 Real-time frequency analysis according to IEC 51260 FFT & Zoom FFT analysis Noise & Vibration tests Vibration Monitoring Sound Power Measuring according to IEC 3744/45/46 Trade marks and owners Windows™ Microsoft Corp. Intel™ Intel Corp. Soundbook™, Apollo™, SAMURAI™ SINUS Messtechnik GmbH

 Open the catalog to page 1
HURRICANE-2

^INUJFi Messtechnik GmbH HurrCane™ Multi-channel System for Sound and Vibration Measurement and Analysis in Mobile and Stationary Applications This powerful and versatile system features small dimensions and minimum power consumption. Its integrated sensor interface allows commonly used sensors to be connected for noise and vibration measurements. Apart from four input and output channels for highly dynamic signals, Hurricane has additional inputs for tacho signals and slowly-fluctuating measurement data. This makes Hurricane especially suitable for measurements in vehicles and on test stands....

 Open the catalog to page 2

All Sinus Messtechnik GmbH catalogs and technical brochures

  1. Apollo

    2  Pages

  2. NoisePAD

    2  Pages

  3. Tango_NMS™

    2  Pages

  4. PassBy

    2  Pages

  5. HARMONIE™

    4  Pages

  6. Soundbook_MK2

    6  Pages

  7. Apollo™_Box

    2  Pages

  8. Boogie™

    2  Pages

  9. Tango™

    2  Pages

  10. COMET

    4  Pages

  11. Pass-by

    2  Pages

  12. AcoustiTube

    1  Page

  13. Apollo_light

    2  Pages

  14. SAMURAI

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.