ZIRCONIUM DIOXIDE OXYGEN ANALYZER RAPID OXYGEN MEASUREMENT FOR OPTIMIZATION ln-situ gas analyzers Sensor Intelligence.
Open the catalog to page 1
FOR EMISSIONS AND PROCESS MEASUREMENTS Reliable and accurate oxygen measurements are essential for meeting the exacting requirements of emissions monitoring, to allow reference values for other gas components to be established, such as SO2, NO, NH3, NO2. Measured values also need to be available quickly to optimize combustion processes and monitor excess oxygen. This is where the ZIRKOR302 zirconium dioxide oxygen analyzer comes into its own with its proven in-situ measurement technology. Incineration optimization Incineration processes require oxygen, which chemically reacts with the fuel....
Open the catalog to page 2
No test gases required Extremely low operating costs Automatic testing and adjustment of the measurement with ambient air Very low maintenance because maintenance intervals are long – only every three months Fast response time Effective plant control (T90 < 20 s) Very large temperature range Exhaust gas temperatures from 0° ... 1400 °C Optional evaluation unit For remote control functions (e.g. mounted in a control room) over a maximum distance of 1,200 m from the analyzer High precision measured values < 0.2% Vol.% across the entire measuring range Innovative current sensor principle The...
Open the catalog to page 3
RAPID OXYGEN MEASUREMENT FOR OPTIMIZATION OF INDUSTRIAL PROCESSES Product description provides fast, reliable measurement of oxygen, even at high temperatures. The analyzer has been designed with safety in mind and does not represent a po- tential ignition source in the measuring gas. The optional evaluation unit enables • Very large temperature range • All gas carrying parts are heated • Automatic testing and adjustment with ambient air or compressed air • Fixed physical zero point Your benefits • No requirement for expensive test • Very low maintenance - maintenance needed only every...
Open the catalog to page 4
In-situ gas analyzers ZIRKOR302 Fields of application • Optimizing combustion processes • Establishing reference values for emissions monitoring • Monitoring excess oxygen • Monitoring inerting processes Detailed technical data The precise device specifications and product performance data may vary and are dependent on the respective application and customer specifications. Analyzer with integrated measuring gas pump Measurement principles Zirconium dioxide current sensor Certified measuring ranges Response time ≤ 20 s With standard measuring gas extraction device, length = 1 m Zero point...
Open the catalog to page 5
ZIRKOR302 In-situ gas analyzers Dimensions (W x H x D) For details, see dimensional drawings 27 kg With standard measuring gas extraction device, length = 1 m With heating for measuring gas extraction device, additional 4 kg ... 6 kg Material in contact with media Power supply Voltage Frequency Power consumption Corrective functions Automatic testing and adjustment with ambient air Integrated components Analyzer with ejector operated by compressed air Measurement principles Zirconium dioxide current sensor Certified measuring ranges Response time Zero point drift ≤ 0.2 Vol.-% within the...
Open the catalog to page 6
Function buttons Arrow keys Menu-driven operation via LC display and membrane keyboard Dimensions (W x H x D) For details, see dimensional drawings 27 kg With standard measuring gas extraction device, length = 1 m With heating for measuring gas extraction device, additional 4 kg ... 6 kg Material in contact with media Power supply Voltage Frequency Power consumption 4 ... 6 bar; particle size max. 1 µm; oil content max. 0.1 mg/m³; pressure condensation point max. –30 °C Corrective functions Automatic testing and adjustment with ambient air Integrated components ZIRKOR302 evaluation unit –...
Open the catalog to page 7
ZIRKOR302 In-situ gas analyzers ZIRKOR302 evaluation unit – cast metal housing Description The evaluation unit provides the user interface, data processing, data output, and control and monitoring functions Enclosure rating Analog outputs 3 outputs: 0/4 ... 20 mA, 500 Ω Galvanically isolated – one output of measured values per connected analyzer Digital outputs 3 relay contacts: 48 V AC, 1 A, 60 W / 48 V DC, 1 A, 30 W Preset for fault, maintenance, and operational check Digital inputs LC display Status LEDs: "Power", "Maintenance," and "Fault" Arrow keys Function buttons Menu-driven...
Open the catalog to page 8
In-situ gas analyzers ZIRKOR302 Evaluation unit; steel sheet enclosure 97.5 (3.84) 90 (3.54) 82 (3.22) ZIRKOR302 evaluation unit; cast metal enclosure 8009620/2015-03 Subject to change without notice
Open the catalog to page 9
ZIRKOR302 In-situ gas analyzers Compressed air unit; enclosure version 350 (13.78) Compressed air unit; mounting panel 350 (13.78) 310 (12.20) Ø 10 8009620/2015-03 Subject to change withou
Open the catalog to page 10
SERVICES Mounting flange, Di=125 mm WWW.MYSICK.COM – SELECT AND ORDER ONLINE Find it quickly and reliably – with the SICK "Finders" Efficiency – with SICK e-commerce tools Product Applications Literature Service Accessories Software Product Finder: We can help you find the right product for your application quickly and easily. Application Finder: Select the application description on the basis of the task, industrial sector or product group. Documentation Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of products from SICK....
Open the catalog to page 11
SICK AT A GLANCE SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With more than 6,500 employees and over 50 subsidiaries and equity investments as well as numerous representative offices worldwide, we are always close to our customers. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in various industries and understand their processes and requirements. With...
Open the catalog to page 12All SICK SENSOR INTELLIGENCE catalogs and technical brochures
-
REGISTRATION SENSORS
24 Pages
-
CLV63x, CLV64x, CLV65x
102 Pages
-
WTB16 Bluetooth®
135 Pages
-
WE9LC-3_A71
3 Pages
-
Safety Switches
20 Pages
-
Automation light grids
8 Pages
-
Encoders and Inclination Sensors
32 Pages
-
Proximity Sensors
324 Pages
-
Dust measuring devices
172 Pages
-
Detection and Ranging Solutions
124 Pages
-
Distance Sensors
404 Pages
-
Vision
124 Pages
-
Top-Products from SICK
556 Pages
-
Fluid Sensors
243 Pages
-
Registration Sensors
276 Pages
-
Magnetic Cylinder Sensors
164 Pages
-
IDENTIFICATION SOLUTIONS
24 Pages
-
Our identification solutions
8 Pages
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Pages
-
FLOWSIC300 Gas flow meters
12 Pages
-
FLOWSIC500 Gas flow meters
16 Pages
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Pages
-
FLOWSIC600 Gas Flow Meter
16 Pages
-
ConVer
12 Pages
-
GM32 In-situ gas analyzers
28 Pages
-
GM35 In-Situ IR Gas Analyzer
16 Pages
-
Encoders
788 Pages
-
Opto Electronic Protective Devices
712 Pages
-
GMS800 Extractive Gas Analyzers
20 Pages
-
WT100-2 energetic
47 Pages
-
VPS Pro Profiling systems
20 Pages
-
Photoelectric Sensors
949 Pages
-
G6 - Global Sensor
20 Pages
-
Hand-Held Scanners IDMx
48 Pages