Product catalog summary
Overview: The document details the TRANSIC100LP and TRANSIC151LP laser oxygen transmitters by SICK, designed for precise in-situ or inline oxygen measurement using Tunable Diode Laser Spectroscopy (TDLS). These devices are suitable for various industrial processes, including explosive atmospheres, offering easy installation and low maintenance.
Specifications:
  • Measurement Principle: TDLS
  • Measuring Ranges: 0-5 Vol.-% / 0-100 Vol.-%
  • Response Time: ≤ 10 seconds
  • Accuracy: ≤ 0.2 Vol.-%
  • Process Temperature: -20°C to +80°C
  • Process Pressure: 800 hPa to 1,400 hPa
  • Ex-Approvals: IECEx, ATEX, NEC/CEC
  • Enclosure Rating: IP 66
  • Oxygen concentration measurement range: 0 to 25 vol.-%
  • Output types: 4-20 mA and 0-20 mA
Features:
  • Real-time measurement directly in the process
  • Self-diagnostics with maintenance display
  • No consumables required
  • Rugged design for contaminated gases
Applications:
  • Inert gas blanketing
  • O2 measurement in process gases
  • Monitoring in explosive atmospheres
  • Process monitoring in fermenters and bioreactors
  • Room air monitoring and quality control
Installation and Configuration: Various configurations are available, including flange, wall bracket, and sample cell options. Supports analog and digital outputs with customizable settings.
Safety and Compliance: Approved for explosive atmospheres, complying with ATEX and IECEx standards, with features for explosion protection.
Accessories: Optional accessories include sample gas cells, filters, and various cable and connection options.
Reconfiguration and Maintenance: Requires a serial interface and terminal program on a PC, to be done in non-hazardous areas. PTFE filter recommended for reference gas inlet.
Electrical Connections: Includes RS-232 and RS-485 interfaces, power supply connections, and digital output for alarms.
SICK LifeTime Services: Offers comprehensive services for product lifecycle support, including training, upgrades, consulting, verification, and product support.
Company Overview: SICK is a global leader in sensor solutions, providing products and services for factory, logistics, and process automation in over 40 countries.
See more

Catalog excerpts

TRANSIC100LP Laser Oxygen Transmitter-1

GMS800 FIDOR® TOTAL HYDROCARBON ANALYZER TRANSIC100LP LASER OXYGEN TRANSMITTER The good nose for oxygen Continuous monitoring of hydrocarbon emissions Gas transmitter

 Open the catalog to page 1
TRANSIC100LP Laser Oxygen Transmitter-2

TRANSIC100LP: Laser oxygen transmitter Simple, fast and low maintenance Process parameters are best measured where they are relevant and present in an unaltered state – directly in the process. "In-situ measuring technology" or "Inline measuring" are the phrases used. The process parameters are determined under process conditions. The TRANSIC100LP is an oxygen transmitter that measures in-situ or "inline". The sensor is designed as a measuring probe. This ensures that the lens system in the transmitter is always optimally aligned and installation is very simple. The measuring task can be implemented...

 Open the catalog to page 2
TRANSIC100LP Laser Oxygen Transmitter-3

The TDLS Tunable Diode Laser Spectroscopy is primarily used in high-end gas analyzers and is characterized by its highly selective measurement capability. The oxygen properties are used for O2 measurement: That means O2 atoms in the near infrared range are stimulated at specific wavelengths. A laser diode modulates the radiation precisely over an absorption peak. The high-energy radiation transfers energy to the O2 atoms and the signals becomes weaker. In the measuring probe, the laser beam hits the O2 atoms and is weakened according to the concentrations of oxygen present there. A receiver measures...

 Open the catalog to page 3
TRANSIC100LP Laser Oxygen Transmitter-4

TRANSIC121LP and TRANSIC151LP: Measuring oxygen in potentially explosive atmospheres An explosion can only occur when all three elements (fuel, an ignition source and oxidant), referred to as the explosion triangle, are present. The primary explosion protection prevents the simultaneous occurrence of a fuel and an oxidant. If flammable substances cannot be avoided, no oxidants may be present. Commission, 1994) for devices and 1999/92/EC (European Commission, 1999) for operation (ATEX Directive) and the harmonized standards, or NEC 500 and NEC 505 in the USA. For use in potentially explosive atmospheres,...

 Open the catalog to page 4
TRANSIC100LP Laser Oxygen Transmitter-5

Dust: II 2 D Ex ibtb IIICTS5°C Db Dust: II 2 D Ex ibtb INCT85°C Db Subject to change without notice

 Open the catalog to page 5
TRANSIC100LP Laser Oxygen Transmitter-6

THE GOOD NOSE FOR OXYGEN Additional information Product description Measuring the oxygen in the process can be quite simple. The TRANSICIOOLP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure 02 reliably. A tech- nology more common in the world of • 02 transmitter based on high-perfor- mance laser spectroscopy (TDLS) atmospheres (FM, ATEX and lECEx • Measurement directly in-situ or extractive using a sample gas cell Your benefits • Measures in real-time directly in the • Easy installation and operation • Self-diagnostics with maintenance high-tech...

 Open the catalog to page 6
TRANSIC100LP Laser Oxygen Transmitter-7

Fields of application • Monitoring of inert gas blanketing in tanks and vessels • O2 measurement in process gases • Measurements in potentially explosive atmospheres • Process monitoring in fermenters and bioreactors • Room air monitoring • Quality monitoring for the production of technical gases • Replacement of extractive paramagnetic oxygen analyzers and electrochemical cells Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant...

 Open the catalog to page 7
TRANSIC100LP Laser Oxygen Transmitter-8

Electrical connection Voltage 24 V DC TRANSIC151LP: 21.6 ... 26.4 V For ATEX/IECEx version via TSA151 power supply, a PELV power supply is mandatory Current consumption Power consumption Corrective functions Test functions Adjustment with ambient air or test gases Contamination check

 Open the catalog to page 8
TRANSIC100LP Laser Oxygen Transmitter-9

Ordering information Our regional sales organization will help you to select the optimum device configuration. Type code TRANSIC111LP Version A With flange for in-situ installation, <0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% D With flange for in-situ installation, <0.5 bar, O2 measuring range 0 ... 100 vol.-% [1] E With sample cell and wall bracket, PN10, O2 measuring range 0 ... 100 vol.-% [1] F With flange for in-situ installation,...

 Open the catalog to page 9
TRANSIC100LP Laser Oxygen Transmitter-10

[1] With certificate for oxygen service [2] For use in clean gas only or with a sample cell [3] Not selectable for the O2 measuring range 0 ... 100 vol.-%. Not recommended for wet gas near dew point. [4] Can be reconfigurated in the field [5] Factory setting: 0 … 25 vol-% O2 [6] Can be reconfigurated in the field (requires a serial interface and a terminal program on PC) [7] Selectable only for the output range of 4 ... 20 mA [8] Factory setting: 10 vol-% O2 [9] PTFE filter for reference gas inlet recommended TRANSIC121LP Version A With flange for in-situ installation, < 0.5 bar, O2 measuring...

 Open the catalog to page 10
TRANSIC100LP Laser Oxygen Transmitter-11

TRANSIC151LP Version A With flange for in-situ installation, < 0.5 bar, O2 measuring range of 0 ... 25 vol.-% B With wall bracket for ambient air measurement, O2 measuring range 2 ... 25 vol.-% C With sample cell and wall bracket, PN10, O2 measuring range 0 ... 25 vol.-% F With flange for in-situ installation, PN10, O2 measuring range of 0 ... 25 vol.-% G With weld-on nozzle for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% H With 3’’ clamp connection for in-situ installation, PN10, O2 measuring range 0 ... 25 vol.-% Filter type 1 No filter [1] 2 Stainless steel mesh 3 PTFE filter...

 Open the catalog to page 11
TRANSIC100LP Laser Oxygen Transmitter-12

TRANSIC100LP Gas transmitters only in a non-hazardous area! [6] Selectable only for the output range of 4 ... 20 mA [7] Factory setting: 10 vol-% O2 [8] For connection between transmitter and power supply TSA151 only SICK Ex i cabel have be used [9] PTFE filter for reference gas inlet recommended [10] Connection to PC should be done only in a non-hazardous area! Use SICK service interface cables only. [11] Do not operate TRANSIC151LP transmitter without TSA151 power supply! Dimensional drawings (Dimensions in mm (inch)) TRANSIC100LP with flange adapter for process measurements below 0.5 bar 310...

 Open the catalog to page 12

All SICK SENSOR INTELLIGENCE catalogs and technical brochures

  1. WE9LC-3_A71

    3  Pages

  2. Safety Switches

    20  Pages

  3. Distance Sensors

    404  Pages

  4. Vision

    124  Pages

  5. Fluid Sensors

    243  Pages

  6. ConVer

    12  Pages

  7. Encoders

    788  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.