MCS300P Multi Component Analyzer System Process monitoring in gases or liquids
Open the catalog to page 1
Sophisticated analyzers for high-value products. Reliable measuring results through photometric process monitoring. Product quality in chemical processes also depends not least on the quality of the process measurement technology. High-value products demand sophisticated meas urement technology. SICK has been delivering suitable measuring systems as well as turnkey complete solutions for many years. MCS300P process measuring devices are generally suitable for use in all process industries. From synthetics production on through exhaust gas cleaning plants up to measuring a wide range of gas...
Open the catalog to page 2
MCS300P Ex: Exact measurement also in Ex conditions Reliable measuring results Also in Ex zones Also for combustible gases Sender unit with operator panel for analyzer Receiver unit SICK cell SICK Ex cell (depending on application) Ex control unit category 3G Comprehensive safety functions for Ex areas The MCS300P Ex with device category 3G or 2G (ATEX) is u sable in Ex zones and 1. The pressurized enclosure does not allow any explosive gases to penetrate; the required permanent overpressure in the enclosure is ensured by protective gas purging with appropriate control systems. For...
Open the catalog to page 3
Simultaneous process monitoring of up to 6 measuring components Product description The MCS300P is an extractive process photometer for measurement of gaseous or liquid media. It measures IR and VIS active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring of toxic or flammable mixtures, it has special process cuvettes with safety devices like twinseals and flushing gas feeds. The heatable cuvettes made of corrosion-resistant materials have a high pressure resistance. Automatic adjustment, innovative operation concept and modern...
Open the catalog to page 4
Application •• Process monitoring in production of vinylchloride or isocyanate •• Process control in chemical industry •• Monitoring of processes in the production of plastics •• Raw gas monitoring in waste incineration •• Monitoring of flue gas purification plants •• Determination of the water content of liquid chemicals Detailed technical data System Measured value Maximum number of measurands Measuring principle Spectral range Measuring ranges More than 60 measuring components available (depending on concentration and sample gas composition), up to 6 components simultanously, 2 measuring...
Open the catalog to page 5
≤ approx. 30 kg without measuring cuvette Material in contact with media Measuring cuvette depending on version Aluminium, coated Supply voltage Standard type: 115 V / 230 V Ex-type: 230 V Ex control device: 230 V Supply frequency Analyzer: 50 ... 60 Hz Ex control device: 48 ... 62 Hz Power consumption Analyzer ≤ 230 W With cuvette heating ≤ 805 W With 2nd heating ≤ 1,450 W Cross-sensitivity compensation of up to 6 interferents Items supplied Via LC-display, via software SOPAS ET (not in the Ex-type) The scope of delivery depends on application and customer specifications.
Open the catalog to page 6
Ordering information Our regional sales organization will help you to select the best fitting device configuration. Dimensional drawings MCS300P, horizontal L2 All dimensions in mm (inch); all weights in kg 8013235/2012-05 Subject to change without notice
Open the catalog to page 7
All dimensions in mm (inch); all weights in kg 8013235/2012-05 Subject to change without notice
Open the catalog to page 8
All dimensions in mm (inch); all weights in kg 8013235/2012-05 Subject to change without notice
Open the catalog to page 9
All dimensions in mm (inch); all weights in kg dimensions in mm 8013235/2012-05 Subject to change without notice
Open the catalog to page 10
www.mysick.com – Your quick access to maximum efficiency MCS300P Search online quickly and safely with the SICK „Finders“ Product Applications Literature Service Connection diagram Accessories Spare part Software Product Finder: We can help you to quickly target the product that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of SICK products. These and other...
Open the catalog to page 11
Leading technologies Unique product range Comprehensive services With a staff of more than 5,000 and over 50 subsidiaries and representations worldwide, SICK is one of the leading and most successful manufacturers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans – there is no need to settle for anything less than the best. •• Non-contact detecting, counting, classifying, positioning and measuring of...
Open the catalog to page 12All SICK SENSOR INTELLIGENCE catalogs and technical brochures
-
REGISTRATION SENSORS
24 Pages
-
CLV63x, CLV64x, CLV65x
102 Pages
-
WTB16 Bluetooth®
135 Pages
-
WE9LC-3_A71
3 Pages
-
Safety Switches
20 Pages
-
Automation light grids
8 Pages
-
Encoders and Inclination Sensors
32 Pages
-
Proximity Sensors
324 Pages
-
Dust measuring devices
172 Pages
-
Detection and Ranging Solutions
124 Pages
-
Distance Sensors
404 Pages
-
Vision
124 Pages
-
Top-Products from SICK
556 Pages
-
Fluid Sensors
243 Pages
-
Registration Sensors
276 Pages
-
Magnetic Cylinder Sensors
164 Pages
-
IDENTIFICATION SOLUTIONS
24 Pages
-
Our identification solutions
8 Pages
-
FLOWSIC300 Ultrasonic Gas Flow Meter
177 Pages
-
FLOWSIC300 Gas flow meters
12 Pages
-
FLOWSIC500 Gas flow meters
16 Pages
-
FLOWSIC600 Ultrasonic Gas Flow Meter
138 Pages
-
FLOWSIC600 Gas Flow Meter
16 Pages
-
ConVer
12 Pages
-
GM32 In-situ gas analyzers
28 Pages
-
GM35 In-Situ IR Gas Analyzer
16 Pages
-
Encoders
788 Pages
-
Opto Electronic Protective Devices
712 Pages
-
GMS800 Extractive Gas Analyzers
20 Pages
-
WT100-2 energetic
47 Pages
-
VPS Pro Profiling systems
20 Pages
-
Photoelectric Sensors
949 Pages
-
G6 - Global Sensor
20 Pages
-
Hand-Held Scanners IDMx
48 Pages