1. Catalogs
  2. SICK SENSOR INTELLIGENCE
  3. GMS800 Extractive Gas Analyzers
video corpo

GMS800 Extractive Gas Analyzers

GMS800 Extractive Gas Analyzers
1 / 20 PagesView full catalog

GMS800 Extractive Gas Analyzers

Product catalog summary
Overview: The GMS800 series by SICK is a modular family of extractive gas analyzers designed for process and emission monitoring. It measures over 60 different gas compounds and is characterized by its flexible configuration and modular design, suitable for a wide range of industrial applications.
Specifications: The GMS800 system includes seven different analyzer modules tailored for specific gas measurement needs, such as DEFOR for UV-active gases and UNOR for NDIR measurements. It supports various enclosure types, including explosion-proof options, and is compliant with EN 15267 and EN 14181 standards.
Applications: The GMS800 is used for emission monitoring in industries like power plants and waste incineration, measuring gases such as NO, NO2, and SO2. It is also used in the chemical and petrochemical industries for process gas measurements, including monitoring sulfur compounds and CO for explosion protection.
Technical Data: The system operates with a gas flow rate of 30-60 l/h and supports sample gas temperatures from 0°C to +45°C. It functions in ambient temperatures of +5°C to +45°C and can be stored at temperatures from -20°C to +70°C. It is compliant with CE and ATEX certifications.
Benefits: The GMS800 offers minimal service and maintenance requirements due to its modular design, easy integration into existing systems, and reliable measurement technology. It supports remote diagnosis via Ethernet and provides accurate results with minimal influence from ambient temperature changes.
Features: The system includes corrective functions, test functions, and supports interfaces like Ethernet Modbus TCP and RS-485 Modbus RTU. It also offers multiple analog and digital I/O for integration and control.
Design and Options: Various designs are available, such as GMS810 and GMS820P, with optional components like a magnetic piston pump and humidity sensor.
Services: SICK LifeTime Services provide consulting, training, upgrades, verification, and support to ensure safety and productivity throughout the machine lifecycle.
Company Information: SICK is a global leader in sensor solutions, present in over 50 countries, providing products and services for industrial applications.
See more

Catalog excerpts

GMS800 Extractive Gas Analyzers-1

TAILOR-MADE GAS ANALYSIS SOLUTIONS FOR PROCESS AND EMISSION MONITORING Extractive Gas Analyzers Sensor Intelligence.

 Open the catalog to page 1
GMS800 Extractive Gas Analyzers-2

Modular analyzer system – flexible configuration, options tailored for almost any application Emission monitoring according to EN 15267 • Emission measurements of very low concentrations, e.g. in power plants, cement plants or waste incineration plants and in the pulp and paper industry • With the analysis module DEFOR, the specialist for gas turbines due to measurement of very low SO2, NO and NO2 concentrations • Monitoring of NOx in denitrification plants by direct measurement of NO and NO2 as well as compiling to NOx in the analyzer • Efficient measurement in denitrification plants • QAL1...

 Open the catalog to page 2
GMS800 Extractive Gas Analyzers-3

Extractive gas analyzers GMS800 4 types of enclosures for easy integration at the installation location 19" rack housing with integrated control unit (BCU), 4 rack units, IP 40 Wall enclosure, IP 65 for use in rough industrial environment, optionally usable in explosion zones 1 and 2 Flame-proof enclosure, IP 65, for use in explosion zone 1 Type GMS811: 19"rack housing with 4 rack units, IP 40 Type GMS840: Wall enclosure, IP 65 for use in rough industrial environment, optionally usable in explosion zone 2 6 Analyzer modules for more than 60 gases DEFOR Modern UV gas analyzer for simultaneous...

 Open the catalog to page 3
GMS800 Extractive Gas Analyzers-4

TAILOR-MADE GAS ANALYSIS SOLUTIONS FOR PROCESS AND EMISSION MONITORING Additional information Product description familiy of extractive analyzers which can measure more than 60 different gas ized by its modular design: 7 analyzing modules, one gas module, I/O modules and an operating unit. Standardized 19" racks as well as system enclosures opti- mized for installation in cabinets can be • 7 different analyzer modules: DEF0R (NDUV, UVRAS), MULT0R (NDIR), • 5 different types of enclosures Your benefits Ex-areas (Zone 1 and 2 according to ATEX) possible • Minimum service and maintenance work as...

 Open the catalog to page 4
GMS800 Extractive Gas Analyzers-5

Extractive gas analyzers GMS800 Fields of application • Emission monitoring according to EN 15267 and process gas measurements • Emission monitoring of very low concentrations • Measurement of smallest concentrations of NO, NO2 and SO2 • NOx monitoring by direct measurement of NO and NO2 • Measurement of sulfur compounds in process gases • CO monitoring for Ex protection • Measurement of smallest concentrations in hydrogen or hydrocarbons Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the...

 Open the catalog to page 5
GMS800 Extractive Gas Analyzers-6

GMS800 Extractive gas analyzers GMS811 design Description 19″ rack enclosure with 4 rack units, for usage with separate control unit (BCU), for integration in cabinets Enclosure rating Power supply Voltage Frequency Power consumption PVDF bulkhead fitting For hose 6 x 1 mm For purge gas or flowing reference gas Option Gas connections: Swagelok 6 mm or Swagelok 1/4″ Wall-mounting enclosure with gas-tight separated analyzing and electronic units, purgable separately Ex-approvals ATEX II 3G Ex nR II T6 II 3G Ex pz II T6 In combination with an external, approved monitoring unit (option) II 2G Ex...

 Open the catalog to page 6
GMS800 Extractive Gas Analyzers-7

Extractive gas analyzers GMS800 GMS820P design Description Flame-proof enclosure for use in Ex-zone 1 areas Ex-approvals IECEx Enclosure rating Power supply Voltage Frequency Power consumption For purge gas or flowing reference gas Option Gas connections: Swagelok 6 mm or Swagelok 1/4″ GMS840 design Ambient temperature Storage temperature Ambient humidity Ex-approvals ATEX NEC/CEC (US/CA) GMS841: Ex nA nC IIC T4 Gc Ex nA nC [ia Ga] IIC T4 Gc GMS842: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, AEx nA nC IIC T4 Gc Ex nA nC IIC Electrical safety Enclosure rating Power supply Voltage...

 Open the catalog to page 7
GMS800 Extractive Gas Analyzers-8

GMS800 Extractive gas analyzers DEFOR analyzer module Description UV gas analyzer for simultaneous measurement of up to 3 gas components Measurement principles NDUV spectroscopy, UVRA spectroscopy 0 ... 10 ppm / 0 ... 100 Vol.-% NO2, SO2: smallest measuring range with daily adjustment of zero point and operation in air-conditioned ambiance with a temperature stability of ±2 °C (*) Response time 4 s Typical at 60 l/h, depending on cell length and gas flow Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of measuring range full scale per week Measuring ranges...

 Open the catalog to page 8
GMS800 Extractive Gas Analyzers-9

Response time ≤ 25 s At 60 l/h, depending on cuvette length, gas flow and number of measuring components Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 % of smallest measuring range per week Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV German Clean Air Regulations EN 15267 EN 14181 MCERTS Corrective functions Manual or automatic adjustment with test gases or adjustment cuvette Test functions Self test...

 Open the catalog to page 9
GMS800 Extractive Gas Analyzers-10

GMS800 Extractive gas analyzers Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller 5 vol%: ≤ 0.05 Vol.-% per week Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV German Clean Air Regulations EN 15267 EN 14181 MCERTS Corrective functions Manual or automatic adjustment with test gases Test functions Self test and fault diagnosis Special versions with highly solvent-resistant or highly corrosion-resistant measuring cells available THERMOR analyzer module Description Heat conductivity analyzer for the determination...

 Open the catalog to page 10
GMS800 Extractive Gas Analyzers-11

Extractive gas analyzers GMS800 UNOR analyzer module Description Highly selective NDIR analyzer for continuous measurement of almost any gas component which absorbs in the infra-red spectral range Measurement principles NDIR spectroscopy 0 ... 26 ppm / 0 ... 100 Vol.-% More than 60 measuring components available Response time 3 s Typical at 60 l/h, depending on cell length and gas flow Sensitivity drift ≤ 1 % of measuring range full scale per week Zero point drift ≤ 1 % of smallest measuring range per week Measuring ranges smaller than 2 x smallest measuring range: ≤ 2 % of smallest measuring...

 Open the catalog to page 11

All SICK SENSOR INTELLIGENCE catalogs and technical brochures

  1. WE9LC-3_A71

    3  Pages

  2. Safety Switches

    20  Pages

  3. Distance Sensors

    404  Pages

  4. Vision

    124  Pages

  5. Fluid Sensors

    243  Pages

  6. ConVer

    12  Pages

  7. Encoders

    788  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.