GM901 Carbon Monoxide Gas Analyzers
12Pages

{{requestButtons}}

Catalog excerpts

GM901 Carbon Monoxide Gas Analyzers - 1

Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING ln-situ Gas Analyzers Sensor Intelligence.

Open the catalog to page 1
GM901 Carbon Monoxide Gas Analyzers - 2

MONITORING CARBON MONOXIDE EMISSIONS INNOVATIVELY AND EFFICIENTLY It is generally accepted that measuring carbon monxide levels is a crucial activity. SICK once again proves the supplier of choice in this field, thanks to the high-performance solution it offers as part of its product portfolio: the GM901 in-situ gas analyzer. With its wide range of applications, this represents a virtually indispensable component when it comes to emissions monitoring and process control – and for just some of the proof of its capabilities, look no further than the over 1,000 installations in which it...

Open the catalog to page 2
GM901 Carbon Monoxide Gas Analyzers - 3

Product versions The GM901 in-situ gas analyzer is available with a measuring probe and in a cross duct version: GM901 – version with measuring probe Open measuring probe (GMP) T-piece with beam splitter GM901 – cross duct version Sender Sender System components System components •• Sender and receiver •• T-piece with beam splitter •• GPP measuring probe (gas permeable probe, verifiable using test gases) or GMP measuring probe (open aperture, purge air unit necessary) •• Evaluation unit •• Sender and receiver •• Evaluation unit Optional components Optional components •• PROFIBUS interface...

Open the catalog to page 3
GM901 Carbon Monoxide Gas Analyzers - 4

CO MEASUREMENT FOR EMISSION MONITORING Additional information Product description a cross-duct or probe type. As a result, it is suited to a broad range of applica- tions - even for difficult measuring tasks • Representative measurement across • Operation via evaluation unit Your benefits • Measurement results in real time due • Fast and simple installation and such as high dust loads, overpressure, critical flow profiles or high measuring Short response times Verifiable with gas-filled cuvette; gas testable probe with test gas Easy, user-friendly operation For more information, just enter...

Open the catalog to page 4
GM901 Carbon Monoxide Gas Analyzers - 5

In-situ gas analyzers GM901 Fields of application • Optimization of all kinds of combustion processes • CO monitoring in coal mills • Process monitoring in food industry • Control of small boiler facilities • Optimization of biomass combustion plants • Roasting processes Detailed technical data The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Cross-duct version Measured values Maximum number of measurands Measurement...

Open the catalog to page 5
GM901 Carbon Monoxide Gas Analyzers - 6

GM901 In-situ gas analyzers GM901 evaluation unit; steel sheet enclosure Description The evaluation unit serves as user interface and is responsible for data processing and output as well as control and monitoring functions Enclosure rating Analog outputs Analog inputs Digital outputs Digital inputs CAN (internal system bus) PROFIBUS DP (option) LC display Status LEDs: “Operation”, “Service”, “Warning” and “Malfunction” Arrow keys Functional keys Steel sheet enclosure Power supply Voltage Power consumption Connection unit Description To lengthen the internal CAN-Bus connection with cable...

Open the catalog to page 6
GM901 Carbon Monoxide Gas Analyzers - 7

In-situ gas analyzers GM901 Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings (Dimensions in mm (inch)) GM901 sender and receiver unit 8008876/2016-09 Subject to change without notice

Open the catalog to page 7
GM901 Carbon Monoxide Gas Analyzers - 8

Sender receiver, T adapter piece and gas testable probe (GPP) Application-specific lengths available on request Subject to change without notice

Open the catalog to page 8
GM901 Carbon Monoxide Gas Analyzers - 9

In-situ gas analyzers GM901 Sender, Empfänger, T-Stück und offene Messlanze (GMP) ANSI flange graduated circle Measuring gap L3 (active measuring path) 250 Probe length, nominal All dimensions in mm Application-specific lengths available on request 8008876/2016-09 Subject to change without notice

Open the catalog to page 9
GM901 Carbon Monoxide Gas Analyzers - 10

GM901 In-situ gas analyzers Evaluation unit; steel sheet enclosure 97.5 (3.84) 90 (3.54) 82 (3.22) 8008876/2016-09 Subject to change without noti

Open the catalog to page 10
GM901 Carbon Monoxide Gas Analyzers - 11

WWW.MYSICK.COM – SEARCH ONLINE AND ORDER Search online quickly and safely – with the SICK “Finders” Efficiency – with the e-commerce tools from SICK Product Applications Literature Service Accessories Software Product Finder: We can help you to quickly target the product that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. Literature Finder: Go directly to the operating instructions, technical information, and other literature on all aspects of products from SICK. Find out prices...

Open the catalog to page 11
GM901 Carbon Monoxide Gas Analyzers - 12

SICK AT A GLANCE SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With more than 6,500 employees and over 50 subsidiaries and equity investments as well as numerous representative offices worldwide, we are always close to our customers. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in various industries and understand their processes and requirements. With...

Open the catalog to page 12