1. Catalogs
  2. SICK SENSOR INTELLIGENCE
  3. FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion
video corpo

FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion

FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion
1 / 138 PagesView full catalog

FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion

Product catalog summary
Summary of FLOWSIC500 Ultrasonic Gas Flow Meter Operating Instructions
1. Important Information
  • Main Hazards: The document identifies risks such as explosion due to gas leaks and material fatigue, emphasizing the importance of preventing damage and ensuring leak tightness.
  • Intended Use: The FLOWSIC500 is designed for measuring gas volume, flow rate, and velocity in pipelines, suitable for explosive atmospheres and combustible gases.
  • User Responsibility: Users must adhere to operating instructions and safety information, with unauthorized modifications voiding warranties and safety approvals.
2. Product Description
  • Operating Principle: Utilizes ultrasonic transit time difference measurement to calculate gas velocity and volume flow rate.
  • Device Components: Includes the gas flow meter, adapters, and optional pressure and temperature sensors for volume conversion.
  • Power Supply: Can be powered by an external intrinsically safe power supply or internal battery packs.
3. Installation
  • Mechanical and Electrical Installation: Guidelines for safe installation, including mechanical fitting and electrical connections, with compliance to safety standards.
  • Hazards: Installation must comply with safety regulations, and work should only be performed when the system is non-pressurized.
4. Start-up and Operation
  • Start-up Procedures: Involves logging in as an authorized user, setting date and time, and checking device status.
  • Operation and Control: Instructions for using the display and optical data interface, with emphasis on proper alignment and connection of transmitters.
5. Maintenance and Troubleshooting
  • Maintenance Procedures: Guidelines for handling and replacing batteries, ensuring compliance with safety standards.
  • Error and Event Logs: Includes status, warning, and error messages with specific codes for diagnostics.
6. Accessories and Spare Parts
  • Accessories: Lists accessories for gas flow meters and volume conversion devices.
  • Spare Parts: Details spare parts available for gas flow meters and volume conversion devices.
7. Standards and Compliance
  • Standards Compatibility: Adheres to several standards, including OIML R137-1&2, EN, and IEC standards for explosive atmospheres.
  • Approvals: Includes Ex approvals such as IECEx, ATEX, and NEC/CEC, classified as IP66.
See more

Catalog excerpts

FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-1

Title Page OPERATING INSTRUCTIONS FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion Installation Operation Maintenance

 Open the catalog to page 1
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-2

Document Information Described Product Product name: FLOWSIC500 Alternating Current Document ID Title: Part No.: Document ID: Version: Release: ATEX: Atmosphères Explosifs: Abbreviation for European standards that govern safety in potentially explosive atmospheres Canadian Standards Association (www.csa.ca) Direct Current High frequency, e. g. HF pulses International Electronical Commission IEC system for certification in accordance with standards for devices for use in potentially explosive atmospheres Ingress Protection: Degree of protection of a device in accordance with IEC/DIN EN 60529;...

 Open the catalog to page 2
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-3

Warning Symbols Information Symbols IMMEDIATE HAZARD of severe injuries or death Information on product condition with regard to protection against explosions (general) Hazard (general) Information on product characteristics related to European Directive ATEX Hazard by electrical voltage Information on product characteristics related to explosion protection in accordance with the IECEx scheme. Hazard in potentially explosive atmospheres Important technical information for this product Hazard by explosive substances/mixtures Important information on electric or electronic functions Hazard by unhealthy...

 Open the catalog to page 3
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-4

About this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Purpose of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Product identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Operation in potentially explosive atmospheres . . . . . . ....

 Open the catalog to page 4
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-5

Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Requirements for use in potentially explosive atmospheres . . . . . . . . . . . . . . . . . . . 37 Criteria for electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Opening and closing the electronics cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Rotating the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 5
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-6

Contacting Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Additional messages in the Event logbook . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Maintenance and Meter Replacement Information on handling lithium batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Information on storage and transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Disposal information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 6
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-7

Conformities and Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 CE certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Standards compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Flow rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

 Open the catalog to page 7
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-8

FLOWSIC500 · Operating Instructions · 8015391/YZF6/V 2-2/2016-07 · © SICK Engineering Gmb

 Open the catalog to page 8
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-9

Important Information Important Information Subject to change without notice Main hazards About this document Intended use Responsibility of user FLOWSIC500 · Operating Instructions · 8015391/YZF6/V 2-2/2016-07 · © SICK Engineering GmbH

 Open the catalog to page 9
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-10

Important Information Main hazards DANGER: Risk of explosion when the gas flow meter is damaged Natural gas flows with line pressure through the gas flow meter. Natural gas can escape when the gas flow meter is damaged which creates a risk of explosion. ▸ Prevent any possible damage to the gas flow meter. When necessary, fit protection devices. ▸ If the gas flow meter is damaged: Stop natural gas feed immediately and purge the FLOWSIC500 with inert gas. WARNING: Hazards through leaks Operation in leaky condition is not allowed and potentially dangerous. ▸ Regularly check leak tightness of equipment....

 Open the catalog to page 10
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-11

Important Information Purpose of the device The FLOWSIC500 serves for measuring the gas volume, volume flow rate and gas velocity of natural gas in pipelines. The FLOWSIC500 with optional volume conversion serves for measuring the gas volume and converting the gas volume measured to base conditions as well as registering data on meter readings, maximums and other data. Product identification Product name: Manufacturer: FLOWSIC500 SICK Engineering GmbH Bergener Ring 27 01458 Ottendorf-Okrilla Germany The type plates for metrological and electrical parameters are located on the gas flow meter....

 Open the catalog to page 11
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-12

Important Information Operation in potentially explosive atmospheres The FLOWSIC500 is suitable for use in potentially explosive atmospheres: ATEX: II 2G Ex ia [ia] IIB T4 Gb, II 2G Ex ia [ia] IIC T4 Gb, II 2G Ex op is IIC T4 Gb IECEx: Ex ia [ia] IIB T4 Gb, Ex ia [ia] IIC T4 Gb, Ex op is IIC T4 Gb US/C: Class I Division 1, Groups C, D T4, Ex/AEx ia IIB T4 Ga Further information on potentially explosive atmospheres → p. 37, §3.4.1. The FLOWSIC500 is suitable for measuring combustible and occasionally ignitable gases corresponding to zones 1 and 2. Refer to the type plate for the configuration...

 Open the catalog to page 12
FLOWSIC500 Ultrasonic Gas Flow Meter with Optional Volume Conversion-13

Important Information Cleaning WARNING: Risk of ignition due to electrostatic charge Under certain extreme circumstances, in Gas Group IIC, exposed plastic and unearthed metal parts of the enclosure may store an ignition-capable level of electrostatic charge. ▸ Implement precautions to prevent the build up of electrostatic charge, e.g. locate the equipment where a charge-generating mechanism (such as wind-blown dust) might occur and clean with a damp cloth. NOTICE: Cleaning instructions ▸ Only clean the FLOWSIC500 with a damp cloth. ▸ Do not use solvents for cleaning. ▸ Only use materials for...

 Open the catalog to page 13

All SICK SENSOR INTELLIGENCE catalogs and technical brochures

  1. WE9LC-3_A71

    3  Pages

  2. Safety Switches

    20  Pages

  3. Distance Sensors

    404  Pages

  4. Vision

    124  Pages

  5. Fluid Sensors

    243  Pages

  6. ConVer

    12  Pages

  7. Encoders

    788  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.