Overview: The document provides technical specifications and functionalities of the FXS501 line leakage tester, which is designed to perform electrical safety tests in compliance with various international standards.
Specifications: The FXS501 can automatically perform the eight most common line leakage tests with a single button. It supports current measurement from 0.001 to 20 mA (with an option for 60 mA) and power measurement up to 63 A for single and three-phase systems. The device measures external voltage from 0 to 260V for single-phase and 0 to 440V for three-phase systems, with a frequency range of 50-60 Hz.
Measurement Capabilities: Leakage current measurement ranges from 0.005 mA to 120 mA, with accuracy and resolution depending on the standards. Voltage measurement ranges from 10V to 300V, with a resolution of 4000 points on a digital display.
Sequence Function: The device can automatically sequence through eight test steps, including dielectric strength, insulation, ground continuity, and leakage tests. It allows for storage of up to 10 sequence setups.
Operating Mode and Protections: The FXS501 requires an insulation transformer for operation and includes protections such as a breaker. It features automatic switching for phase/neutral reversal, neutral open, and earth/ground equipment open.
Compliance and Standards: The tester complies with VDE, UL, CSA, and main EN European standards related to the LOW VOLTAGE DIRECTIVE (LVD). It supports standards like IEC1010-1, IEC335-1, IEC950, and others.
Remote Control and Software: The device can be controlled remotely via Ethernet, RS232C, PLC, or IEEE488-2 interfaces. It is compatible with National Instruments Labview for remote control and includes SXSPRO software for comprehensive test management.
General Characteristics: The FXS501 is a table-top unit with a metal case, operating at 230V or 115V single phase, with a consumption range of 70 to 600VA. It operates within a temperature range of 0°C to +45°C and can be stored between -10°C to +60°C.
Optional Accessories: Various optional accessories are available, including calibration kits, dummy boxes, and different front plug configurations for international compatibility.
See more

Catalog excerpts

FXS501-1

■ Line leakage tester ■ automatically performs the 8 most common line leakage tests with 1 single button ■ Current measurement from 0.001 to 20 mA (60 mA option) ■ power measurement up to 63 A single phase and three phases (option), cos 9 (option), and functional test (option) ■ 8 available measurement circuits in order to comply with most of the international standards ■ ETHERNET, RS232C, PLC or IEEE488-2 interfaces The FXS501 line leakage tester (also called leakage current measurement tester) complies with the electrical safety testing requirements according to the VDE, UL, CSA standards and to the main EN European standards involved in the LOW VOLTAGE DIRECTIVE (LVD). The FXS501 can be coupled to the XS series in order to cover the 4 tests required by the electrical safety testing standards. (dielectric strength test, insulation test and ground bond test). Those 4 electrical safety tests can automatically be performed with 1 single action : “one button check-up”. AUTOMATIC SWITCHING • Phase/Neutral reversed • Neutral open • Earth/ ground equipment open • Internal/external voltage OPERATING MODE •With insulation transformer (compulsory according to the standards) PROTECTIONS • Breaker OUTPUTS • Customized single or three phases front plug, depending on the country LINE LEAKAGE TEST FUNCTION External voltage • 0 to 260V single phase • 0 to 440V three phases Maximum power (option) •63A, 14000 VA in single phase •63A, 14000 VA per phase in three phases External frequency • 50 - 60 Hz Leakage current measurement • Measured current from 0.005 mA, up to 120 mA depending on the standards •Accuracy from +/- (2%+5|jA) depending on the sta ndards • Resolution from 0,1 jA depending on the standards Voltage measurement • Measured voltage from 10V to 300V •Accuracy from +/- (2,5%+0.5V) • Resolution : 4000 points digital display Measurement circuit •20000 for the most of standards except for EN61010-1 (10000) SEQUENCE FUNCTION • 8 test steps automatically sequenced among: Dielectric strength test, Insulation, Ground continuity, Leakage, Pause, Multiple continuity (when FXS connected to othr XS unit) • Each test function is linked to a parameter memory number. 10 sequence setups storage • Example of a sequence performing a Ground bond continuity test with parameters stored in memory number 1, followed by an insulation test with parameters stored in memory number 0, followed by a hipot test with parameters stored in memory number 2, followed by a line leakage test with parameters stored in memory number 6, followed by a power measurement test with parameters stored in memory number 3 L1: CONTINUITY 1 L2: MEGOHM 0 L3: HIPOT 2 L4: LEAKAGE 6 L6: POWER 3 SXSPRO software on a PC computer makes possible to perform as many tests as wished

 Open the catalog to page 1
FXS501-2

Line leakage tester - FXS501 REMOTE CONTROL SOFTWARE National Instruments Labview Drivers • Software drivers which can be used in a Labview application to remote control the XS se ries unit through RS232C or IEEE488-2 interface • Remote control of all the unit functions • CD-R including install and uninstall files • Measurement results in Excel format Application software • SXSPRO: powerful software controlling the XS series according to your appli cation (Access & Excel results, bar code management, customized test reports, customized user guidance through the test, user level man agement, production...

 Open the catalog to page 2
FXS501-3

Presentation •Table top unit • Metal case Dimensions • Height: 131 mm •Width: 440 mm • Depth : 450 mm Weight • depen ds on configuration Power •230V or 115V +/-15% single phase, 47-63 Hz • Consu mption: 70 to 600VA depend ing on test Operating temperature 0°C to +45°C Storage temperature -10°C to +60° C Over-voltage category CATII Pollution degree 2 Safety class Class I (earth connection) single phase or three phases single phase or three phases isolation transformer up to 7000 switching up to 7000 VA XS42, XS48A, XS41, ... manual or automatic single phase or three phases variac up to 7000 VA

 Open the catalog to page 3
FXS501-4

Line leakage tester – FXS501 OPTIONNAL ACCESSORIES MG68-CH Swiss front plug, for single phase leakage and power measurement MG68-GB English front plug, for single phase leakage and power measurement MG68-EUR Schuko european front plug, for single phase leakage and power measurement MG68-USA USA front plug, for single phase leakage and power measurement CALIBRATION KITS & DUMMY BOXES XS91-LEAK Calibration box for Leakage current Measurement SD1000 Dummy box for Leakage current Measurement Specifications subject to change without notice S E F E L E C S . A . S . ⎪ Parc d’activités du Mandinet ⎪...