INV-1500 - 1

Batteries Chargers Inverters Conve rters INV-1500 1500 VA inverter Key features • Cooling features Cold plate induction Natural convection Internal forced air • Fault protection Over/under frequency Over/under output voltage Over/under input voltage Over temperature Input time delay Approved installations • Hawker 800 family Environmental • Operating temperature -55°C to 71 °C • Storage temperature -55°C to 85°C • Operating altitude Sea level to 55,000 ft MEGGiTT smart engineering for extreme environments Modular design and years of experience in solid state inverter design provide the formula for the efficient low-cost construction of the INV1500. Drawing from over 50 years' experience, Securaplane's designers have developed a modular design with a low EMI signature and proven electronic and magnetic technology. Power FET transistors provide significantly higher efficiency than earlier transistor devices, reducing heat within the inverter which increases reliability. Fault protection on our inverters includes over and under frequency, over and under input and output voltage, over temperature, input time delay and remote fault indication. When a fault is detected for more than five seconds the protection mechanisms will cause the inverter to shut down. Securaplane's power conversion products achieve industry-leading MTBF levels, power quality, electromagnetic compatibility and lightning rejection which are necessary to support more electric and composite fuselage development trends in commercial aviation. Securaplane Our product competencies and services: Aircraft security systems | Airborne video cameras |Aircraft batteries | Battery chargers | Inverters | Converters | Wireless integration © Securaplane | January 2014

Open the catalog to page 1
INV-1500 - 2

Batteries Chargers Inve rters Converters Input Output • Voltage Rated voltage: 26-30 VDC Extended voltage: 20-36 VDC • Typical current 28V at 1500 VA 67A • Voltage Voltage output one: 115 VAC +5%/-7% Voltage output two: 26 VAC + 8%/-7% Note—the 26 VAC output rating is 500VA which can be provided simultaneously with the 115 VAC output provided the total output power loading does not exceed 1500VA • Power Continuous at rated input 1500VA Continuous at 20VDC input 1350VA Two hours at rated input 1650VA Five minutes at rated input 2250VA • Frequency: 400Hz ± 1% • Power factor: 0.8 lag to...

Open the catalog to page 2

All Securaplane Technologies catalogs and technical brochures

  1. CAM series

    2 Pages