Product catalog summary
Features:
  • Supports thermocouple types E, J, K, N, R, S, T, and B.
  • Outputs in °C, °F, °R, or K.
  • Ethernet TCP/IP & UDP protocol support.
  • 1000Vdc channel-to-channel isolation and 600Vdc input isolation.
  • 160dB 0-60Hz Common Mode Rejection (CMRR) and 50-60 Hz noise rejection.
  • Open thermocouple test and IEEE1588 PTPv2 synchronization.
  • Available in 16, 32, and 64 channel configurations.
Applications:

The DTS4050 Digital Temperature Scanner is suitable for turbine engine, diesel engine, and compressor test cells, as well as industrial environments like boiler and oven temperature monitoring. It features a corrosion-resistant stainless steel enclosure and is designed to withstand high EMI noise environments.

General Description:

The DTS4050 series is an advanced thermocouple scanning system, replacing the DTS3250. It accepts 16, 32, or 64 thermocouple inputs and includes low pass filters, 22-bit A/D converters, and a DSP microprocessor. It is designed for high-noise environments and includes an isothermal block for uniform temperature reference.

Temperature Measurement:

The DTS4050 measures mV signals from thermocouples and compensates for cold junction temperature. It uses NIST mV-temperature tables stored in flash memory for conversion to engineering units, outputting data via Ethernet.

Legacy Compatibility:

The DTS4050 is backward compatible with existing Scanivalve DTS data systems, allowing DTS3250 and DTS4050 modules to operate on a single network.

Common Mode Rejection:

Designed for high EMI environments, the DTS4050 features a robust architecture with 1000Vdc channel-to-channel isolation and 600Vdc input isolation, providing unmatched common mode rejection.

Specifications:
  • Communication: Ethernet 100BaseT, RS-232 for configuration.
  • Power: 18–36Vdc, varying amperage based on configuration.
  • Weight: Varies by configuration, ranging from 12.00 lbs to 25.0 lbs.
  • Accuracy: Varies by thermocouple type, with detailed accuracy specifications provided.
  • Operating Temperature: Varies by configuration, with optional heater available.
Ordering Information:

Options include standard units with optional heaters and rack mount kits for 32 and 64 channel configurations. A Software Development Kit is available for custom data acquisition programming.

See more

Catalog excerpts

Model DTS4050-1

Features • Accepts type E, J, K, N, R, S, T, and B • Engineering Unit output, °C, °F, °R, or K • Ethernet TCP/IP & UDP protocol • 1000Vdc channel-to-channel isolation • 600Vdc Input isolation • 160dB 0-60Hz Common Mode Rejection (CMRR) • 50 - 60 Hz noise rejection • Open thermocouple test • IEEE1588 PTPv2 synchronization • 16, 32, and 64 channel General Description The DTS4050 series temperature acquisition system represents the next generation of intelligent thermocouple scanning. The DTS4050 is a direct replacement for its predecessor, the DTS3250. The DTS4050, Digital Thermocouple Scanner, accepts 16, 32, or 64 thermocouple inputs. It incorporates integral low pass filters, 22 bit A/D converters, and a DSP microprocessor. The DTS module is specifically designed for high-noise environments and as such can withstand unmatched common mode noise. An isothermal block is incorporated for the Uniform Temperature Reference (UTR) for each 16 channel input. NIST thermocouple tables for standard thermocouple types are stored in flash memory. The microprocessor uses these look-up tables to convert mV inputs to Engineering Units. Temperature data are output in °C, °F, °R, K, millivolts and counts. The DTS4050 accuracy for types E, J, K, N, and T is ± .25°C to ±0.5°C depending on the thermocouple type and the useful temperature range. (Refer to accuracy table for a complete listing of supported thermocouples and associated accuracies) Multiple standard thermocouple types may be used with one DTS4050. Applications The DTS4050 Digital Temperature Scanner is ideal for use in turbine engine, diesel engine, and compressor test cells, as well as other industrial environments such as boiler and oven temperature monitoring. The module has a corrosion resistant, stainless steel enclosure with a locking lid for input terminal access. The standard DTS is insulated, rugged, and splash resistant and incorporates shock mounts for vibration isolation. The DTS4050’s electronics were specifically designed to endure punishing high EMI noise environments while still being able to provide accurate engineering data. The DTS4050 is typically mounted in close proximity to the test article, thus minimizing thermocouple wire lengths. Shorter thermocouple wires not only reduce errors, but also lower costs due to the elimination of extension cables. Field calibrations can be used to modify coefficients which can also improve overall system accuracy. The standard DTS4050 module accepts two wire or three wire shielded thermocouples. LabView® is a registered trademark of National Instruments.

 Open the catalog to page 1
Model DTS4050-2

Common Mode Rejection The DTS4050 has a hardware supported slave implementation of the Precision Time Protocol defined by IEEE 1588-2008, otherwise known as PTP V2. This protocol is used to synchronize the DTS4050 internal clock over the Ethernet network. The DTS4050 product line was specifically designed to operate in environments with high levels of EMI. The DTS’ unique architecture allows it to precisely read microvolt signals even amongst hundreds of volts of common mode noise. Supporting this capability, the DTS is built around a robust front end. Every thermocouple input channel has its...

 Open the catalog to page 2
Model DTS4050-3

DTS4050 Communications The DTS4050 module interfaces directly to a host via an Ethernet connection. Scanivalve’s free ScanTel communications program is designed to assist a user in establishing communications and data collection, as well as configuring the DTS module. Additionally available is a Software Development Kit for users who want to write their own detailed data acquisition program in LabVIEW®. This Development Kit includes the Configuration Utility software and examples to assist a user in the setup of the system. An OPC driver is also available (16Tx only). Mating Connector Type: 100BaseT...

 Open the catalog to page 3
Model DTS4050-4

16Tx Screw Terminal Inputs 32Tx Screw Terminal Inputs 16Tx Panel Jack Connector Inputs 32Tx Panel Jack Connector Inputs 64Tx Screw Terminal Inputs Scanivalve Headquarters 1722 N. Madson Street Liberty Lake, WA 99019 Tel: 509-891-9970 800-935-5151 Fax: 509-891-9481 e-mail: [email protected] Printed in USA © 2014, Scanivalve Corp. *Specifications are subject to change without notice.

 Open the catalog to page 4

All Scanivalve Corporation catalogs and technical brochures

  1. 3207/3307-PTP

    4  Pages

  2. 3217/3218-PTP

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.