General Technical Specifications for Rubb Buildings and Shelters GTS - 01/2005

Open the catalog to page 1
Rubb Buildings and Shelters - 2

8.0 Double Skin Insulation 10.0 Heating 11.0 Dehumidification 12.0 Air Conditioning buildings built to last... 1.0 RUBB BUILDINGS LTD Rubb Buildings Ltd has for over 30 years manufactured versatile, relocatable buildings for all types of applications throughout the world. Our buildings withstand climatic conditions ranging from the tropical to the Arctic. From the outset Rubb Buildings has maintained a strict quality policy encompassing design, materials, and the manufacturing process. We feel we can therefore say with confidence that, “We make relocatable buildings built to last”. 2.0...

Open the catalog to page 2
Rubb Buildings and Shelters - 3

4.2.1 Fabric quality: Rubb buildings erected over 20 years ago still have their original cladding. The fabric has been tested with respect to tensile strength, elongation, tearing strength, bursting strength, coating adhesion and resistance to flexing according to BS 3424. The fabric is flame retardant and self-extinguishing to BS 5438 Test 2B (test certificates are available on request). FOUNDATION ALTERNATIVES Rubb Quality 453 and 480 PVC impregnated Polyester Fabric Fabric: Construction: Dtex: Total Weight: Thickness: Tensile Strength: Tear Strength: Fire characteristics: 453 Polyester 9...

Open the catalog to page 3
Rubb Buildings and Shelters - 4

8.0 DOUBLE SKIN INSULATION Heat loss can be reduced in our buildings by the provision of an inner skin attached to the inner structure. By adding an insulating material between the two skins, it can be made to comply to the latest British Standards Building Regulations. Various types of insulating material which can be used to suit individual requirements / preferences include, standard glass fibre and Rockwool. As part of the service we also undertake a comprehensive heating installation designed to comply with individual requirements and locations. We can utilise existing sources on site,...

Open the catalog to page 4
Rubb Buildings and Shelters - 5

BVR RANGE OF BUILDINGS Special purpose Rapid Erection structures and Sunshades. BVE RANGE OF BUILDINGS Available in single span configurations, alternative sidewalls optional.

Open the catalog to page 5
Rubb Buildings and Shelters - 6

With spans up to 25m and sidewalls up to 5.5m 15.0 TH SHELTER RANGE Rubb shelters have a similar specification to buildings, but because they are designed for more temporary usage they do not conform to UK Building Regulations for wind and snow loads. Rubb manufacture standard shelter kits in the THA, THB and TH ranges as shown in the tables. Any length can be supplied in 3m long modules for all shelter designs. Models THA, THB have vented gable ends which are welded to the first roof section for extra rigidity. All shelters are easy to erect by unskilled labour with no special tool...

Open the catalog to page 6
Rubb Buildings and Shelters - 7

Weight including cover (kg) Weight including cover (kg) Standard door opening (w x h) (m) Volume/in m per m floor area Snow loading capacity (kg/m2) Standard door opening (w x h) (m) FOUNDATION ALTERNATIVES Volume /in m3 per m2 floor area TH RANGE: With the TH, no foundation frame is included. A foot plate is welded to the bottom of the leg section. This can be bolted to a wood foundation with coach screws or on to a steel channel foundation shown in figs 1. and 2. THA AND THB RANGE: With these shelters a continuous steel angle foundation is included. Alternative foundation arrangements are...

Open the catalog to page 7
Rubb Buildings and Shelters - 8

18.0 CUSTOM DESIGNED STRUCTURES all dimensions in metres Rubb understands that not all our customers requirements fit our standard building solutions. We have therefore built up a competent engineering team that can make exactly what a customer demands. We have as a result of this made a wide variety of 'non-standard' buildings. These vary from very high side wall structures (up to 23m to date), to circular structures, to lean-too with internal cranes, to water tank covers. We are willing to consider any task that encompasses our technical know how in order to satisfy customer requirements....