LD05-HTGF

LD05-HTGF
1 / 13 PagesView full catalog

LD05-HTGF

Product catalog summary
Overview: The RIEGL LD05-HTGF is a digital laser distance meter designed for precise time-of-flight laser range measurement, optimized for high-temperature and hazardous environments. It features advanced digital signal processing for accurate multi-target distance measurements under poor visibility conditions.
System Components: The system includes an optical head and a separate electronics box connected by a duplex glass-fiber cable. The optical head is small, lightweight, and resistant to high temperatures and radiation.
Key Features:
  • Separate mounting of electronics and measuring head for flexibility in critical environments.
  • Improved measurement capability in poor visibility conditions like rain, dust, and fog.
  • Short infrared laser pulses for interference immunity and narrow measurement beam for spatial resolution.
  • Measurement capability on various surfaces regardless of angle and characteristics.
Main Applications:
  • Distance and level measurements in high-temperature areas.
  • Level measurement of liquid steel in melting pots or transfer ladles.
  • Robotic applications in nuclear power plants.
  • Measurement of position, width, and thickness of glowing slabs in rolling mills.
Technical Specifications:
  • Measurement range: 2 m to 10 m for high-temperature targets.
  • Measurement accuracy: ±10 mm in High Penetration Mode, ±15 mm in Fast Mode.
  • Measurement rate: 100 Hz in High Penetration Mode, 1000 Hz in Fast Mode.
  • Laser wavelength: Near infrared with beam divergence varying by distance.
  • Laser classification: Class 1M according to IEC 60825-1:2007.
Interfaces and Outputs:
  • Standard interfaces include WEB, LAN TCP/IP, and RS232/RS422 ports.
  • Industrial interfaces include analog output (4-20 mA) and digital switching output.
  • Optional infrared radiation channel for measuring target surface temperature.
Physical and Environmental Data:
  • Electronics unit dimensions: 246x130x97 mm, weight: 2.8 kg, protection class: IP64.
  • Optical head dimensions and weight vary by model, with protection class ranging from IP62 to IP64.
  • Operating temperature range: -20°C to +80°C for optical heads, +15°C to +50°C for electronics unit.
See more

Catalog excerpts

LD05-HTGF-1

The RIEGL LD05-HTGF is a laser distance meter based on precise time-of-flight laser range measurement especially suited for demanding applications under critical environmental conditions, i.e. high ambient temperature or hazardous environment. It is additionally optimized for very high target temperatures. It uses state-of-the-art digital signal processing to enable precise distance measurement for complex multi-target situations even under bad visibility conditions. Digitizing the echo signal and subsequent analysis enables multi-target distance measurements. The measuring system consists of an optical head meeting the requirements of the relevant application and a separate electronics box, connected by a duplex glass-fiber cable of variable length with connectors on both sides. • Electronics unit and measuring head can be mounted separately according to requirements resulting from critical environmental conditions • Further improved measurement capability in demanding situations causing poor visibility (rain, dust, fog). • Short infrared laser pulses providing excellent interference immunity • Narrow measurement beam with low divergence for excellent spatial resolution • Measurement to almost any surface regardless of the angle of incidence of the beam and the surface characteristics • Significant enhancement of the maximum range based on predetection-averaging visit our webpage www.riegl.com RIEGL ilf LASER MEASUREMENT SYSTEMS

 Open the catalog to page 1
LD05-HTGF-2

General Description LD05-HTGF Principle of Operation data i/o control / communication processor transmitter online full waveform analysis analog receiver digital electronics unit Target Transmitter lens Reflection coefficient r Receiver lens optical head An electrical pulse generator periodically drives a semiconductor laser transmitter, emitting infrared light pulses, which are fed into a glass fiber cable. The pulses are guided to the optical head and collimated by the transmitter lens. Part of the echo signal reflected by the target is coupled into the glass fiber cable via the receiver lens...

 Open the catalog to page 2
LD05-HTGF-3

General Description LD05-HTGF Main Applications • • • Distance and level measurements in high-temperature areas Level measurement of liquid steel in melting pots or in transfer ladles Robotic applications in nuclear power plants Measurement of the position, width, and thickness of glowing slabs in rolling mills The LD05-HTGF is optimized for measuring very hot and glowing targets in steel plants, rolling mills, foundries etc.: Transmitter and receiver optics are equipped with narrow-band optical filters to avoid disturbances of the measurement caused by the radiation of light and heat from the...

 Open the catalog to page 3
LD05-HTGF-4

General Description LD05-HTGF Digitizing the echo signal and analyzing it allows excellent clutter suppression under demanding environmental conditions, i.e., in the presence of dust, smoke or fumes. To meet different application challenges, user parameters as measurement rate, maximum target count (first target only, last target only, all targets) or sensitivity are adjustable. Standard Interfaces: • WEB Interface for configuration via WEB browser Industrial Interfaces: • • Analog output 4 – 20 mA Digital switching output (2x) Optional Infrared Radiation Channel: With this option the LD05-HTGF...

 Open the catalog to page 4
LD05-HTGF-5

The technical data can be influenced by the environmental conditions to a considerable extent, especially by the following parameters and conditions: • Surface temperature and reflection characteristics of the target • Distance to the target • Angle of incidence of the measurement beam • Optical attenuation of the gases between target and instrument 1) Depending on the surface temperature and the reflection coefficient of the target 2) One sigma @ 5 m range under RIEGL test conditions (except measurements at reflective foil / retro-reflective targets). 3) With self-adapting measurement...

 Open the catalog to page 5
LD05-HTGF-6

Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 6 of 13

 Open the catalog to page 6
LD05-HTGF-7

1) Operating range selectable via TCP/IP port or serial interface. 2) Switching points adjustable via TCP/IP port or serial interface Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 7 of 13

 Open the catalog to page 7
LD05-HTGF-8

1) With the optional telescope, the temperature range is only between -10° C and +60° C. Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 8 of 13

 Open the catalog to page 8
LD05-HTGF-9

Technical Data LD05-HTGF Dimensional Drawings Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 9 of 13

 Open the catalog to page 9
LD05-HTGF-10

case: main dimensions: weight: protection class: temperature range: aluminium, black anodized 120 x 80 x 50 mm 0.67 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) bottom view www.riegl.com Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 10 of 13

 Open the catalog to page 10
LD05-HTGF-11

case: main dimensions: weight: protection class: temperature range: aluminium, black anodized (stainless steel version on request) 133 x 0 65 mm 0.4 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 11 of 13

 Open the catalog to page 11
LD05-HTGF-12

case: main dimensions: weight: protection class: temperature range: recommended air pressure: aluminium, black anodized 500 x 120 x 70 mm approx. 4.4 kg IP62 (glass fiber cables attached) -20° to +80° C (operation and storage) 2 - 4 bar Data sheet, RIEGL LD05-HTGF, 2018-04-03 page 12 of 13

 Open the catalog to page 12
LD05-HTGF-13

case: main dimensions: weight: protection class: temperature range: recommended air pressure: aluminium, colorless anodized 655 x 0 285 mm 10 kg IP64 (glass fiber cables attached) -20° to +80° C (operation and storage) 2 - 4 bar protection tube mounting flange optical head with cooling *) scribed circle diameter Copyright RIEGL Laser Measurement Systems GmbH © 2018 - All rights reserved. Use of this data sheet other than for personal purposes requires RIEGL’s written consent. This data sheet is compiled with care. However, errors cannot be fully excluded and alternations might be necessary. Datasheet...

 Open the catalog to page 13

All RIEGL LASER MEASUREMENT SYSTEMS GMBH catalogs and technical brochures

  1. RiUNITE

    4  Pages

  2. RIEGL VUX-120

    8  Pages

  3. RIEGL VUX-240

    6  Pages

  4. PH-VUX

    2  Pages

  5. RIEGL VPX-1

    2  Pages

  6. RIEGL VP-1

    2  Pages

  7. RIEGL VUX-SYS

    4  Pages

  8. RiPROCESS

    4  Pages

  9. RDBLib

    2  Pages

  10. RiCOPTER-M

    2  Pages

  11. RIEGL DR1560i

    2  Pages

  12. RiVLib

    4  Pages

  13. RiCOPTER

    2  Pages

  14. RiHYDRO

    2  Pages

  15. RiACQUIRE

    4  Pages

  16. LD05-A80

    5  Pages

  17. LD05e-A10

    4  Pages

  18. LD05e-HT

    4  Pages

  19. LD05-A10GF

    10  Pages

  20. RiWaveLIB

    2  Pages

  21. BathyCopter

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.