Catalog excerpts
EPX™ SERIES Product Catalog
Open the catalog to page 1Radiall is a community of dedicated individuals with a shared purpose: simplify life for all those who innovate. Our manufacturing expertise allows us to deliver lighter and smaller products that simplify implementation and drive performance. We recognize that simplification starts with us, but proves its true benefits when it reaches you.
Open the catalog to page 2Contents Introduction 1-3 Disconnect applications 1-4 Rack and panel applications 1-5 CHARACTERISTICS Disconnect connector technical characteristics 1-6 Rack & panel connector technical characteristics 1-7 Technical characteristics for inserts & contacts 1-8 to 1-9 INSERTS Insert selection table 1-10 How to order EPX® inserts 1-11 EPX® insert arrangements 1-12 to 1-14 CONTACTS Signal & power crimp contacts 1-15 Oversized and reduced crimp barrel contacts 1-16 Coaxial crimp contacts 1-17 Twinax and triax crimp contacts 1-18 Quadrax & BMA crimp contacts 1-19 LuxCis® fiber optic contacts 1-20...
Open the catalog to page 3Introduction Radiall is recognized in the Aerospace and Defense industries for offering one of the broadest innovative product portfolios for connector interconnect solutions. The benefit of our experience with ARINC connectors permits Radiall to provide customers with a strong and global solution. The EPX® series offers a wide range of solutions based on two insert sizes with a large variety of shells and contacts. This product range provides an excellent trade-off between the number of available contacts and the space used. The EPX® series is completely modular and expandable. EPX®...
Open the catalog to page 5EPX® SERIES Disconnect Applications Specially designed for panel integration on EWIS applications, EPX® disconnect connectors cover cable-to-cable and PCB-to-cable links in major commercial and business jet aircrafts. The connector can be easily identified by the locking device located directly on the connector (quarter turn device for A1 and B1 and central screws for EPXB2). This disconnect solution offers secure mating while answering OEM’s most stringent requirements, and provides: 1- Modularity with three shell sizes: EPXA1, EPXB1 and EPXB2 - available as lightweight shells and...
Open the catalog to page 6Rack and Panel Applications In response to the need of system miniaturization and new equipment design, Radiall offers EPX® connector solutions for Line Replaceable Unit (LRU) and Line Replaceable Module (LRM). Discover more about these blind mate connectors: EPXB2 for LRU Largely used in distributed architecture, small Line Replaceable Units in an aircraft need compact, lightweight and cost effective connectors. EPXB2 connectors equipped with centering guide will combine high density, low efforts and lightweight features. Discover the whole range of EPXB inserts offering from signal to...
Open the catalog to page 7EPX® SERIES Disconnect Connector Technical Characteristics ELECTRICAL CHARACTERISTICS EMI shielding effectiveness EN2591-213 Frequency (MHz) - Shell to shell conductivity < 2.5 mQ, operating voltage: 400 Vrms or 500 Vdc at sea level, according to EN2591-205 - Voltage stability (ground block): Maximum variation 4mV according to SAE AS 81714 (MIL-T-81714) - Lightning strike: • 5kA - 1600V for EPX® connectors in aluminium version • 3kA - 1600V for EPX® connectors in composite version ENVIRONMENTAL CHARACTERISTICS - Temperature range: according to EIA364-32 and EN2591-305 • For EPXB2 aluminium,...
Open the catalog to page 8EPX® SERIES Rack & Panel Connector Technical Characteristics ELECTRICAL CHARACTERISTICS EMI shielding effectiveness EN2591-213 Frequency (MHz) - Shell to shell conductivity: < 2.5 m Q, operating voltage: 400 Vrms or 500 Vdc at sea level, according to EN2591-205 - Lightning strike: 5kA - 1600V ENVIRONMENTAL CHARACTERISTICS - Temperature range: -65°C/+125°C (-85°F/+257°F) - Temperature life: 1000 hours at maximum temperature - Salt spray: 96 hours EN2591-307 EIA 364-26 test condition A - Humidity: 10 days with temperature variation from -10°C to +65°C EIA 364-31 Method 4, test condition B -...
Open the catalog to page 9EPX® SERIES Technical Characteristics for Inserts & Contacts ELECTRICAL CHARACTERISTICS Electrical characteristics conform to SAE AS 39029 (MIL-C-39029 type A) Contacts conform to EN3155-076 and EN3155-077 Go online for data sheets & assembly instructions RadlallO Visit www.radiall.com and enter the part number
Open the catalog to page 10Technical Characteristics for inserts and contacts Retention forces indicated below are valid for terminated contacts (as per EN2591-409 and EIA364-29) - Insert retention: 400N (90 lbs) EN2591-410 EIA 364-35 - Maximum insert displacement in the shell cavity: 0.30mm (.012 in.) EPX® SERIES Go online for data sheets & assembly instructions. RadlallO Visit www.radiall.com and enter the part number.
Open the catalog to page 11EPX® SERIES Insert Selection Table INSERTS Insert name should be used when ordering EPX® insert Insert code should be used when ordering EPX® assembly kit Inserts available in Bulkhead class are identified with the following logo: NOTE: (1] Only contacts marked with an asterisk [*] are included with EPX® insert kit. All other contacts must be ordered separately (coax, twinax, quadrax and fiber optic contacts] Go online for data sheets & assembly instructions RadlallC# Visit www.radiall.com and enter the part number
Open the catalog to page 12How to order EPX® inserts Only crimp contacts can be delivered with insert Series prefix Insert size111 A: Insert for EPXA B: Insert for EPXB1, EPXB2, EPXB3 or EPXB4 Class'21 E: Environmental N: Non-environmental (no rear grommet, no interfacial seal) H: Non-environmental with a rear grommet, available for pin insert only (recommended for crimp contacts) T: Non-environmental with an interfacial seal, available for pin insert only (recommended for PC tail contacts) B: Bulkhead insert with interfacial seal and a Bulkhead rear grommet, available for pin insert only Insert name Refer to table...
Open the catalog to page 13EPXA Insert Arrangements Insert name 00 Insert code 0 Blank insert (1) Insert name 1C1 Insert code A 1 x size 5 coax contacts Insert name 1P1 Insert code B 1 x size 5 power contacts Insert name 04 Insert code C 2 x size 15 or 16 contacts 2 x size 12 contacts Insert name 09 Insert code D 3 x size 20 contacts 6 x size 15 or 16 contacts Insert name 14 Insert code E 14 x size 20 contacts Insert name 14M Insert code F 8 x size 22 contacts 3 x size 20 contacts 3 x size 15 or 16 contacts Insert name 17 Insert code G 12 x size 22 contacts 5 x size 20 contacts Insert name 20 Insert code H 20 x size...
Open the catalog to page 14All RADIALL catalogs and technical brochures
-
ULTRA LÉGER
38 Pages
-
LuxCis® ARINC 801
2 Pages
-
LuxCis® ARINC 801 Contacts
14 Pages
-
BNC 75
28 Pages
-
EPX™ - EN 4644
70 Pages
-
SHF3 UF
2 Pages
-
SELF-LOCK CONNECTORS
2 Pages
-
ANTENNAS
4 Pages
-
COAXIPACK 2
15 Pages
-
SMA/SMA-COM/BMA
53 Pages
-
BNC/BNC 75 HDTV/BNC-TRX
31 Pages
-
ADAPTERS
37 Pages
-
4.1-9.5/4.3-10/QLI/7-16
25 Pages
-
NSX ARINC 600
6 Pages
-
GPS Antenna Solutions
2 Pages
-
Telecom
6 Pages
-
MCX/MMCX/MMS/MMT/MML
25 Pages
-
QUICKFUSIO™ SERIES
26 Pages
-
SMB/SMB-LOCK/SMC
29 Pages
-
MPX Series
45 Pages
-
R163/R143/R127/R327
23 Pages
-
N/TNC/C
37 Pages
-
SSMA/SSMB/SSMC
15 Pages
-
SHF Cable Assemblies
38 Pages
-
Fiber Optic Products
226 Pages
-
COAXIAL, RF & MICROWAVE
591 Pages
-
MMBX/SMP-MAX
17 Pages
-
SPACE
6 Pages
-
SMPM / SMP / SMP-LOCK™/ SMP-COM
28 Pages
-
Q-MTITANTM ARINC 846
2 Pages
-
C-MTitan™
2 Pages
-
DSX Series SAE AS81659 Arinc 404
63 Pages