1. Catalogs
  2. PWI lnc.
  3. 6900135-001

6900135-001

6900135-001

6900135-001

Product catalog summary
Specifications
  • Input Voltage DC: Minimum 18 VDC, Typical 28 VDC, Maximum 33 VDC
  • Input Current: 1 Amp
  • Output Voltage: 400 VAC (with a note that lamp load milliamps, open circuit max voltage is 1750 VAC)
  • Dimming: 2 Step Dimming
  • Lamp Length: 12 to 52 inches
  • Weight: 145 grams
  • Operating Temperature: -20 to +55 degrees Celsius
Connector and Component Details
  • Mating Connector Plug: 3100022-001 (KINGS# 1705-14)
  • Additional Connector Plug: 3101212-005 (AMP# 350809-1)
  • Pins: 3101208-000 (AMP# 350547-7)
  • Strain Relief: 3101214-008 (AMP# 643030-4)
  • Screw: 3802118-002 (#6-3/8" TYPE 2, PN. HD. SHT. MET.)
Wiring and Installation
  • Typical Wiring for Inverter 6900135-001: Includes connections for GND, Dim Control, +28 volt DC, and two N/C (not connected) pins.
  • Installation Schematic: Provides a typical setup for connecting the unit to lamp P/N 7300343-001 or other compatible lamps with specified connector and shielding requirements.
Additional Notes
  • Control: 2 Step Dimming Control with options for Bright and Dim settings.
  • Output Shield: JP1 and JP2 are designated as output shields.
See more

Catalog excerpts

6900135-001-1

MATING CONNECTOR PLUG: 3101212-005; (AMP# 350809-1) PINS (5): 3101208-000; (AMP# 350547-7) STRAIN RELIEF 2 EACH: 3101214-008; (AMP# 643030-4) SCREW 2 EACH: 3802118-002; (#6-3/8" TYPE 2, PN. HD. SHT. MET.

 Open the catalog to page 1
6900135-001-2

1. Unit connects to lamp P/N 7300343-001 or other shaped lamps configured with connector and Shielding requirements.