90 KVA AC GROUND POWER UNIT
2Pages

{{requestButtons}}

Catalog excerpts

90 KVA AC GROUND POWER UNIT - 1

90 KVA AC GROUND POWER UNIT • Remote fault Diagnosis – Standard Scope. • Highly reliable Deutz Diesel engine. • Meets latest EPA norms. • Digital System - Field tested proven system. - Ensured safety to Aircraft. - Total Digital Monitoring of engine and output parameters. • Walk Away – Protection (Un attended Operation) • Low Noise level. • Meets MIL and ARP Standards. The Most Reliable Aircraft GSE

Open the catalog to page 1
90 KVA AC GROUND POWER UNIT - 2

Rated Output Engine Alternator 90 KVA at 0.8 PF Lagging DEUTZ DIESEL / equivalent MAK / Equivalent brushless, 3 phase, constant voltage alternator with built in AVR. Class F / H Voltage unbalance 90 KVA at 0.8 pf lagging, 3 phase 4 wire system. 115V (Line to Neutral) and 200V (Line to Line). a. 1% at balanced load. b. Within 4% with 1/3rd load on one phase with two other phases unloaded. Voltage transient : ±20% and recovery to within ±1% of the steady state value in 150 milli seconds. Phase difference Frequency Freq. regulation Freq. modulation Freq. transient & recovery : 120 ±1.50°. :...

Open the catalog to page 2

All POWER FORCE TECHNOLOGIES PTE LTD catalogs and technical brochures

  1. GPU285VDC

    1 Pages

  2. GPU140KVATM

    2 Pages

  3. GPU140KVA

    2 Pages

  4. GPU90KVA

    2 Pages

  5. GPU60KVA

    2 Pages