POL-21005-EX - 1

r?Nt ugJTiLk; Point Obstruction Lights POL EX LED Hazardous Location Compliances: Class I, Division 2, Groups A B C D, T5 at -40 deg C to +55 deg C* Class I, Zone 2, Groups IIA IIB+H2 IIC, T5 at -40 deg C to +55 deg C* Certified FAA L-81 0 by Intertek Testing Service (ETL) per FAA AC 150/5345-43G Complies with ICAO Annex 14 Low Intensity Types A (10 cd) & B (32 cd) ETL Listed to UL 844 & UL 1598; Report No. 3110856CRT-009c ETL Listed to UL 1598A Marine Vessels ETL Listed to CSA C22.2 No. 1 37-M1981 & No. 250.0-04 Canada Registered ISO 9001:2008 Compliance to UK CAP 168 Table 6A.1 Low Intensity (Group A) American Bureau of Shipping (ABS) Type Approved Product The POL Hazardous Location series of red LED aviation obstruction lights presents the highest grade technical features and the most options available in the industry. POL steady-burning obstruction lights are used to mark tall structures that present hazards to air navigation. At night, these lights warn pilots when installed in accordance with FAA AC 70/7460-1 and applicable FCC and iCAO rules. Note: FAA approved “lamp" number 631 See important alarms note on specifications page. Power Photometric — Color — Entry — Classified — Style & Options Supply Specification Area 2: 220v F: ICAO Type A 3: 12v DC B: Trans. Canada 4: 24v DC B: ICAO Type B 5: 48v DC B: UK CAP 168 Group A 6: 277v 10B: 1 -inch, Bottom EX: Explosion-Proof D: Double ** 34B: %-inch, Bottom Class I, Division 2 NC: NVG Compatible M20B: Metric, Bottom Class I, Zone 2 S3: w/Junction Box M25B: Metric, Bottom single only ** * T6 at -40 deg C to +40 deg C ** 1 -inch thread only For alarm, transfer, flashing and other control options, see page 2 Marine Treatment standard for the POL-EX and is used for all marine, high salt content air and corrosive environments. The fixture shall be treated for marine conditions by cleaning per US Department of Defense TT-C-490 method Hi, pretreated with chrome-free aluminum conversion coating per US MH-C-5541 type ii, epoxy powder base coat primer and glossy polyester powder coat finish in color RAL 6003 (FED-STD-595 color #14097) dark green. Powder coating per US Department of Defense MH-PRF-24712A type Vi and oven cured.

Open the catalog to page 1
POL-21005-EX - 2

Options ADD THE SELECTED UNIT TO EACH POL LIGHT 1 HAZARD°US L°CAT|°N The PL10760-xx Control Unit is Class I, Division 2 and must be installed within 3-ft (1 -meter) of its associated POL-EX obstruction light. Proper installation and sealing in accordance with all applicable standards is the responsibility of the installer. See page 4 for enclosure details.

Open the catalog to page 2
POL-21005-EX - 3

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION POL EX SPECIFICATIONS The red LED lighted (specify: voltage) aviation obstruction light shall be tested and certified FAA L-810 (ICAO low intensity Type B). The obstruction light shall operate properly at 50 or 60 Hz at an input voltage supply of 120V (93V to 144V) or 220V units (176V to 250V). Within the preceding ranges, the output to the LED board shall be a controlled, stabilized constant current. The obstruction lights shall be listed and labeled for use in hazardous locations: Class I, Division 2, Groups A, B, C, D & T5 and...

Open the catalog to page 3
POL-21005-EX - 4

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION PL10760 ALARM & MONITORING UNIT The Alarm & Monitoring Unit must be installed in accordance with all applicable local electrical codes within 3-ft (1-meter) of the POL EX light fixture. The PL10760 monitors the LEDs and translates the signal into a form usable by a POC controller or other alarm scheme. Two listed enclosures are used depending on the functions required. The following are the standard applications. Enclosure A is used for the following versions: S2 S4 DT D2 D4 D7 Enclosure B is used for the following versions: D2.2...

Open the catalog to page 4
POL-21005-EX - 5

POINT OBSTRUCTION LIGHTS POL EX LED v5 HAZARDOUS LOCATION POWER CONSUMPTION PER POL EX LIGHT HEAD Type Note: For option –NC, add 1.0 watts (1.1 VA) *Power consumption for AC units includes the effect of the unit’s power factor which accounts for the difference between watts and volt-amperes. Measurements were made at the nominal AC voltages. The operating range for 120v units: 93 - 144v; for 220v units: 176 - 250v; for 277v units: 263 -291v. REPLACEMENT PARTS Note: Single POLs and the fixture heads of double POLs are permanently sealed. In the event of failure, the fixture must be returned...

Open the catalog to page 5