Catalog excerpts
Enabling the Extraordinary To Fly To Rower To Live MEGGHT Piezoelectric dynamic pressure sensor MAIN KEYWAY Key features • +986°F (+530°C) operation; +1040°F (+560°C) intermittent operation • Small dynamic pressure measurements even under high static pressure • Balanced differential output • Hermetically sealed • Integral hardline cable • All Inconel and stainless steel construction INCHES (MILLIMETERS] Meggitt model 522M37A is a high quality piezoelectric pressure sensor designed to measure small dynamic pressure fluctuations, even in the presence of high static pressure. The sensor can also operate at very high temperatures; up to +938°F continuously and up to +1040°F intermittently. Model 522M37A features an all welded, Inconel and stainless steel construction with a metal-sheathed, mineral-insulated integral hardline cable. Output is via an integral three-pin (one pin not used) receptacle. The output signal is a balanced, differential signal. A differential input charge amplifier is appropriate for use with this sensor. Common applications include: gas turbine combustion monitoring, high pressure steam and propulsion system testing. Recommended compatible cables are the 6917M169-ZZZ, 6917M170-ZZZ and 6917M171-ZZZ or equivalent (ZZZ designates cable length in inches) which are low noise, twisted pair cable assemblies terminating to pigtail, BNC and PC06A-8-2P connector respectively.
Open the catalog to page 1MEGGHT Piezoelectric dynamic pressure sensor Specifications The following performance specifications conform to ISA-RP-37.2 and are typical values, referenced at +75°F (+24°C), 4 mA, and 100 Hz, unless otherwise noted. Calibration data, traceable to National Institute of Standards and Technology (NIST), is supplied. Dynamic characteristics Measurement range Sensitivity Resonance frequency, minimum Sensitivity deviation over temperature -67°F to +986°F (-55°C to +530°C) Vibration sensitivity Electrical characteristics Output signal type Resistance Room temperature, +75°F (+24°C) Internal...
Open the catalog to page 2Piezoelectric dynamic pressure sensor 1. Intermittent temperature exposure is defined as 5 minutes over a 30 minute period. 2. For short cable lengths, provision must be made to ensure receptacle is not exposed to temperatures greater than +500°F (+260°C). Minimum cable length is 12 inches. Cable length “ZZZ”is in inches and is determined by model dash number, i.e. 522M37A120 has a cable length of 120 inches. 522M37A – ZZZ Integral hardline cable length in inches Basic Model Number Continued product improvement necessitates that Meggitt reserve the right to modify these specifications...
Open the catalog to page 3