video corpo

TWSBF

TWSBF

TWSBF

Product catalog summary
Applications
Designed for use as a stop bar on FAA and military taxiways.
Benefits
  • Long lamp life of 1500 hours at full intensity, extending to over 3000 hours in field conditions.
  • Energy-efficient with stable color due to dichroic filters.
  • Simple design for easy maintenance; no sealant needed for prism fixing.
  • No optical adjustments required after replacing lamp, filter, or prism.
  • Includes a valve for watertightness testing post-overhaul.
  • Dome temperature remains below 160°C at 6.6A.
Performances
  • 6.35 mm protrusion minimizes vibrations, enhancing lifespan.
  • Smooth dome profile reduces sensitivity to snowplough blades.
  • Unidirectional with an 8" diameter.
  • Sturdy yet lightweight due to drop-forged dome and cast aluminum cover.
  • Light output remains effective in heavy rainfall.
  • O-Ring placement prevents dirt accumulation.
  • Protection degree: IP67; Temperature range: -55°C to +55°C.
Installation
  • Compatible with 8” diameter bases; adaptor ring available for 12” bases.
  • Specific tools provided for precise installation.
Compliances
  • FAA: L-852S AC150/5345-46
Photometric Performances
Details on light distribution and intensity are provided, ensuring compliance with FAA standards.
Renewal Parts
  • Includes dome with prism, O-Rings, gaskets, lamp, and other essential components.
Accessories
  • Various bases, adaptor rings, and installation tools available for different setups.
Shipping Weights and Volumes
  • Light Unit: 2.9 kg, 0.007 m3
  • Shallow Base: 3.2 kg, 0.007 m3
  • Light Unit & Adaptor Ring: 6.05 kg, 0.013 m3
Note: Design and specifications are subject to change without notice.
See more

Catalog excerpts

TWSBF-1

INSET STOP BAR LIGHT COMPLIANCES FAA: L-852S AC150/5345-46 APPLICATIONS Stop Bar for FAA and military taxiways BENEFITS • 1500 hours lamp rated life at full intensity, but over 3000 hours in field operating conditions • Significant energy saving and stable chromaticity thanks to the use of dichroic filters • Designed and manufactured with simplicity and easy to maintain • No use of sealant to fix the prisms in the dome thanks to customized gaskets, making their replacement quick and easy • No optical adjustment after lamp, filter or prism replacement • Valve for watertightness test after overhaul • Dome temperature less than 160°C at 6.6A PERFORMANCES • 6.35 mm protrusion strongly reduces vibrations to aircrafts and to light itself, increasing its lifetime • Dome smooth outer profile makes the light less sensitive to snowplough blades • Unidirectional, 8" dia. • Drop-forged dome and cast aluminium lower cover make the fitting sturdy, but lightweight too for ease handling in the field • Light output practically not affected by heavy rainfall thanks to the shallow channel in front of the prism windows • O-Ring placed outside the dome to avoid dirt deposits between light and base • Protection degree: IP67 • Temperature range: -55°C to +55°C INSTALLATION • Suitable for 8" dia. bases • Adaptor ring for installation on 12" dia. bases • Specific tools available for easy and precise installation

 Open the catalog to page 1
TWSBF-3

www.ocem.com [email protected] Lamp: 100 = 1x105W 6.6A with reflector Mounting Assembly: O = No Mounting Assembly R = Adaptor Ring 8”-12” dia. Options: F = Fuse Cutouts Shallow Base 8” dia. ø340 ø320 ø303 ø203.2 ø165 Via della Solidarietà, 2/1 40056 Valsamoggia Loc. Crespellano – Bologna (Italy) Tel: +39 051 66 56

 Open the catalog to page 3
TWSBF-4

www.ocem.com [email protected] Shipping Weights and Volumes RENEWAL PARTS FOR LIGHT UNIT 1 Dome with prism and gaskets 2 O-Ring for dome 3 O-Ring for lower cover 4 Prism gasket 5 Prism 6 Teflon gasket 7 Mounting plate 8 Filter 9 Lamp 10 Lampholder 11 Fuse Cutout 12 Insulated Strip with Hardware 13 Lower cover with plug and valve 14 O-Ring for base 15 FAA L-823 plug 16 Valve for watertightness test Refer to the relevant technical manual for the complete list of the available spare parts ACCESSORIES 315.1230 Base L-868 type, class IA, size B, 24" deep * 315.1420 Flange ring with pavement dam for L-868 base,...

 Open the catalog to page 4

All OCEM - Airfield lighting catalogs and technical brochures

  1. LHI

    4  Pages

  2. LHP

    2  Pages

  3. AGLC

    6  Pages

  4. SCS

    7  Pages

  5. SCC

    2  Pages

  6. DIAM4200

    6  Pages

  7. SO

    2  Pages

  8. VC30

    4  Pages

  9. TWOF

    4  Pages

  10. LETE

    4  Pages

  11. LETG

    4  Pages

  12. LIRH

    4  Pages

  13. AEOL

    4  Pages

  14. LERA

    4  Pages

  15. LIFL

    8  Pages

  16. LIRD

    4  Pages

  17. TDZF

    4  Pages

  18. FEAC

    4  Pages

  19. PAPI MULTI

    4  Pages

  20. LIRT

    4  Pages

  21. LERE

    4  Pages

  22. LIRC

    4  Pages

  23. LIRE

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.