Catalog excerpts
PRODUCT FLYER Oscilloscopes CONTENTS PXI Oscilloscope Portfolio Overview Oscilloscope Probes 8-Bit PXI Oscilloscopes: Optimized for Cost or Speed 10-Bit and 12-Bit PXI Oscilloscopes: Optimized for Speed, Resolution, and Density 14-Bit PXI Oscilloscopes: Optimized for Resolution and Density 24-Bit PXI Oscilloscope: Flexible Resolution Platform-Based Approach to Test and Measurement PXI Instrumentation Hardware Services Page 1 | ni.com | Oscilloscopes NATIONAL ^INSTRUMENTS
Open the catalog to page 1PXI Oscilloscope Portfolio Overview NI offers a wide range of oscilloscope options with variable bandwidths, sample rates, ADC resolutions, voltage ranges, and channel densities. Since all NI PXI Oscilloscopes use the same software driver, models can be mixed and matched to optimize performance and cost for your application’s mixed needs. 8-Bit Scopes: Optimized for Cost or Speed 10-Bit and 12-Bit Scopes: Optimized for Speed, Resolution, and Density 14-Bit Scopes: Optimized for Resolution and Density 24-Bit Scope: Flexible Resolution Page 2 | ni.com | Oscilloscopes
Open the catalog to page 2Oscilloscope Probes An oscilloscope probe is a fundamental part of an analog measurement system. Without an appropriate probe, the best oscilloscope is useless. For that reason, it is essential to choose the right probe to connect the circuit under test to your oscilloscope. Passive probes have the most widespread use in application and are comprised of only passive circuit elements. Active probes are ideal in cases where extremely low capacitance is required for high-frequency measurements or a measurement needs isolation from a given ground reference. Current probes are ideal for...
Open the catalog to page 3Table 2. NI active probes range from 800 MHz to 2.5 GHz bandwidth. Single-Ended and Differential Active Probes Page 4 | ni.com | Oscilloscopes
Open the catalog to page 4Table 3. NI offers Hioki current probes that range from 5 ARMS to 500 A measurements. Maximum Continuous Current Output Voltage Rate (Volts per Amp) Rise Time Oscilloscope Input Impedance Require the use of the two-channel PS-OP01 power supply or PS-OP02 four-channel power supply Figure 1. Hioki current probes require power supplies and also may need short cable adapters if using with SMA/SMB scopes or BNC scopes with closely adjacent channels. Page 5 | ni.com | Osci
Open the catalog to page 5PXI Oscilloscope + Probe Compatibility Not all PXI Oscilloscopes can be used with all probes - a passive probe's 1 MQ input capacitance range may not accommodate the 1 MQ input capacitance of a certain oscilloscope, and current probes can only be used with oscilloscopes that have a 1 MQ input. All of NI's oscilloscope probes have BNC connections, so PXI Oscilloscopes with SMA or SMB front panel connectors will require adapters, as noted in the table below. Single-Ended Passive Probes SP500X - Y Y Y Single-Ended and Differential Active Probes 1 Requires SMB to BNC adapter 2...
Open the catalog to page 6• Software: Includes InstrumentStudio™ support for interactive measurements, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Two analog channels • 100 MHz - 5 GHz analog bandwidth • Edge, digital, immediate, and software standard triggers • Additional window, hysteresis, glitch, runt, and width triggers on PXIe-5110, 5111 and 5113 Optimized for Cost or Speed NI's 8-bit PXI Oscilloscopes range from the lowest cost 100 MHz PXIe-5110 model to the widest bandwidth 5 GHz PXIe-5186 model. They provide the measurement performance of traditional...
Open the catalog to page 750 Q Bandwidth 1 MQ Bandwidth ADC Resolution Channels Maximum Sample Rate 50 Q Full Scale Input Voltage Range 50 Q Maximum Voltage Offset (Depends on Input Range) 1 MQ Full Scale Input Voltage Range 1 MQ Maximum Voltage Offset (Depends on Input Range) Input Channel Connector Input Capacitance (Characteristic) User-Programmable FPGA Maximum External Calibration Cycle Divide by number of Divide by number of Divide by number of channels used channels used channels used 0.04 to 10 Vpk-pk 0.04 to 10 Vpk-pk 0.04 to 10 Vpk-pk 0.04 to 40 Vpk-pk 0.04 to 40 Vpk-pk 0.04 to 40 Vpk-p 5 GHz 500...
Open the catalog to page 8• Software: Includes InstrumentStudio support for interactive measurements, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • 60 MHz – 1.5 GHz analog bandwidth • Edge, hysteresis, digital, immediate, and software standard triggers • Additional window trigger on PXIe-5105 • Two, four, and eight analog channel options Optimized for Speed, Resolution, and Density NI’s 10-bit and 12-bit PXI Oscilloscopes optimize the opposing specifications of sample rate, ADC resolution, and channel density into high-performing, general-purpose products. They...
Open the catalog to page 9Table 6. NI’s 10- and 12-bit oscilloscopes range from 60 MHz to 1.5 GHz options. 50 Q Bandwidth 1 MQ Bandwidth ADC Resolution Channels Maximum Sample Rate 50 Q Full Scale Input Voltage Range 50 Q Maximum Voltage Offset (Depends on Input Range) 1 MQ Full Scale Input Voltage Range 1 MQ Maximum Voltage Offset (Depends on Input Range) Input Channel Connector Input Capacitance (Characteristic) User-Programmable FPGA Maximum External Calibration Cycle Page 10 | ni.com | Oscilloscopes NATIONAL ^INSTRUMENTS
Open the catalog to page 10• Software: Includes InstrumentStudio support for interactive measurements, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Two, four, and eight analog channel options • 100 MHz - 400 MHz analog bandwidth • Edge, window, hysteresis, digital, immediate, and software standard triggers • Additional video trigger on PXIe-5122 • User-programmable Xilinx Kintex-7 FPGA on PXIe-5164, 5170, 5171, and 5172 Optimized for Resolution and Density NI’s 14-bit PXI Oscilloscopes are optimized for high ADC resolution and often, high channel density as well. They...
Open the catalog to page 1150 Q Bandwidth 1 MQ Bandwidth ADC Resolution Channels Maximum Sample Rate 50 Q Full Scale Input Voltage Range 50 Q Maximum Voltage Offset (Depends on Input Range) 1 MQ Full Scale Input Voltage Range 1 MQ Maximum Voltage Offset (Depends on Input Range) Input Channel Connector Input Capacitance (Characteristic) User-Programmable FPGA Maximum External Calibration Cycle Independent sampling Independent sampling channels channels N/A 0.25 to 100 Vpk-pk ± 248.75 V BNC 20.2 pF Xilinx Kintex-7 410T 2 Years Independent sampling Independent sampling Independent sampling...
Open the catalog to page 12All National Instruments catalogs and technical brochures
-