1. Catalogs
  2. Minco
  3. Flameproof RTD Sensors – Metric Dimensioned

Flameproof RTD Sensors – Metric Dimensioned

Flameproof RTD Sensors – Metric Dimensioned

Product catalog summary
Overview
Flameproof RTD sensors are engineered to contain and prevent explosions from spreading to the surrounding environment. They are suitable for use in hazardous locations, specifically Zone 1 or Zone 2, and are approved under IEC/EN 60079-0, IEC/EN 60079-1, and the ATEX directive 94/9/EC. These sensors feature a tip-sensitive, stainless steel or MgO filled RTD probe for fast response and include a spring-loaded holder for optimal probe contact. They are available with U.S. or metric threads.
Specifications
  • Temperature Range: -50 to 260°C (-58 to 500°F).
  • Material: Stainless steel with copper alloy tip for tip-sensitive probes; all stainless steel for other RTDs and fittings.
  • Connection Head: Options include 316 stainless steel (IP66), aluminum alloy (IP65), or epoxy-coated aluminum alloy (IP66).
  • Pressure Rating: 50 psi (3.4 bar) for spring-loaded holder; 100 psi (6.9 bar) for fluid seal fitting.
  • Insulation Resistance: Minimum of 100 megohms at 100 VDC.
  • Connection: Terminal block for wires up to AWG 14.
  • Time Constant: In moving water, 1.5 seconds for single element tip-sensitive, 7 seconds for dual element, and 10 seconds for all stainless and MgO filled.
  • Special Options: Higher temperature ranges available.
Hazardous Area Requirements
For detailed information on classifying hazardous areas and protection methods, as well as standards and agencies like FM, CSA, CENELEC, and ATEX, visit the Minco website.
See more

Catalog excerpts

Flameproof RTD Sensors – Metric Dimensioned-1

Overview Flameproof sensors are designed to contain an explosion as well as prevent the transmission of an explosion to the surrounding atmosphere. These sensors are suitable for use in Zone 1 or Zone 2. ■ Approved for use in hazardous locations defined by IEC/EN 60079-0 and IEC/EN 60079-1, ATEX directive 94/9/EC (KEMA 03 ATEX 2389 X), and ^ II 2 G Ex d IIC T6 ■ Features tip-sensitive, all stainless or MgO filled RTD probe for fast response ■ Spring-loaded holder ensures good probe contact ■ U.S. or metric threads Specifications Temperature range: -50 to 260°C (-58 to 500°F). Material: Tip-sensitive probe: Stainless steel with copper alloy tip. All stainless RTD: Stainless steel. MgO filled RTD: Stainless steel. Fittings: Stainless steel. Connection head: 316 stainless steel IP66, Type 3, 4, and 4X, Aluminum alloy IP65, Type 3 and 4, or Epoxy-coated aluminum alloy IP66, Type 3, 4, and 4X. Pressure rating: Spring-loaded holder: 50 psi (3.4 bar). Fluid seal fitting: 100 psi (6.9 bar). Insulation resistance: 100 megohms min. at 100 VDC, leads to probe case. Connection: Terminal block for wires up to AWG 14. Time constant: Typical value in moving water. Tip sensitive: Single element 1.5 seconds. Dual element 7 seconds. All stainless and MgO filled: 10 seconds. Special options: Higher temperature ranges. Hazardous area requirements For more information on how to classify a hazardous area, methods of protection, and the various standards and agencies (including FM, CSA, CENELEC and ATEX), visit www.minco.com.! page 1 | © 2014 Minco | mincocomponents.com MINCO