Model CPG1500 - 1

Calibration technology WIKA data sheet CT 10.51 for further approvals see page 4 - 5 Applications ■ Oil and gas industry ■ Maintenance and service facilities ■ Calibration service companies and service industry ■ Simple calibrations directly on site ■ Pressure test Special features ■ Measuring ranges up to 0 ... 10,000 bar (0 ... 150,000 psi), vacuum and absolute pressure ranges also available ■ Accuracy: up to 0.05 % (incl. calibration certificate) ■ Intrinsically safe version ■ Logger function with up to 50 measured values per second ■ Communication with WIKA-Cal software over precision digital pressure gauge, model CPG1500 Description General information The model CPG1500 precision digital pressure gauge takes the concept of an analogue gauge, and raises it to a level only matched by digital calibrators. The accuracy of digital measurement technology and the simplicity of an analogue gauge are combined together to create the CPG1500, which in terms of performance, ease-of-use, and instrument features, is unmatched in the pressure measurement market. Accuracy The CPG1500 offers an accuracy of 0.1 % of span (optional 0.05 % of span) and is temperature-compensated in the range of -10 ... +50 °C (14 ... 122 °F). Readings can be displayed in one of 26 pressure and 5 level units or also in customer-specific units, so that intricate conversions are avoided. Sampling rate The measuring rate can be user-defined to match the type of measurement required. Standard applications usually use three measured values per second. If required, this rate can also be set to 50 measured values per second. Via an energy-saving function, the CPG1500 switches automatically into “sleep” mode, in this mode the battery life can be increased up to 2,500 hours. Features Through the new and innovative menu navigation, simple operation is ensured. The clear display, with integral bar graph display and large text area, assists with the effective analysis of the widest variety of measuring points. With the MIN/MAX function, the highest and lowest pressures can be accessed immediately and saved automatically. IwikaII ^ Part of your business WIKA data sheet CT 10.51 • 05/2017 Data sheets showing similar products: Digital pressure gauge; model CPG500; see data sheet CT 09.01 Test pumps, hydraulic; CPP series; see data sheet CT 91.05 Test pumps, pneumatic; model CPP30; see data sheet CT 91.06 Calibration software WIKA-Cal; see data sheet CT 95.1

Open the catalog to page 1
Model CPG1500 - 2

Software WIKA-Cal calibration software is available for the CPG1500. WIKA-Cal also offers, over and above PC-supported calibration, the management of the calibration and instrument data in an SQL database. WIKA-Wireless is available for the data transfer. Certified accuracy For each digital pressure gauge, the accuracy is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a DKD/DAkkS calibration certificate for this instrument. Measuring range 1) Expanded accuracy of 0.2 % FS 2) Expanded accuracy of 0.15 % FS 3) Not possible as flush...

Open the catalog to page 2
Model CPG1500 - 3

7) The user-defined units can only be set via the WIKA-Cal software. The CPG1500 must feature WIKA-Wireless. 8) To use the logger function, WIKA-Cal software is needed. The logger data can be downloaded with the WIKA-Cal demo version as a CSV file. The live logger, an accurate data analysis or a direct certificate creation can be used with the logger template WIKA-Cal. 9) For hazardous areas, only the following types are allowed: ■ Duracell, Simply by Duracell MN1500 ■ Duracell, Duralock Plus Power MN1500 ■ Varta, RAYOVAC Maximum Plus 4006 WIKA data sheet CT 10.51 • 05/201

Open the catalog to page 3
Model CPG1500 - 4

Base instrument Communication (optional) Interface WIKA-Wireless 10) Weight Standard: incl. batteries approx. 680 g ( 1.5 lbs) with protective rubber cap: approx. 820 g (1.81 lbs) 10) Requires a PC with Bluetooth® 2.1 interface Approvals Logo Description C€ RS © EU declaration of conformity European Union ■ EMC directive ■ Pressure equipment directive ■ R&TTE directive EN 300 328 harmonised frequency range 2,400 ... 2,500 MHz is used; Bluetooth® Classic, max. transmission power 10 mW. The instrument may be used without limitations in the EU and also CH, NO and LI. ■ RoHS...

Open the catalog to page 4
Model CPG1500 - 5

1) Calibrated in vertical mounting position with process connection facing downwards Approvals and certificates, see website CPG1500 without protective rubber cap WIKA data sheet CT 10.51 • 05/2017

Open the catalog to page 5
Model CPG1500 - 6

WIKA data sheet CT 10.51 • 05/2017

Open the catalog to page 6
Model CPG1500 - 7

Threaded connection 9/16 - 18 UNF WIKA data sheet CT 10.51 • 05/2017

Open the catalog to page 7
Model CPG1500 - 8

(T) Warning notice when: ■ Exceeding or dropping below the pressure range ■ Exceeding or dropping below the temperature range ■ Logger memory is more than 90 % full ■ Instrument error or battery status < 10 % (2) Log: Logger function active/inactive (3) Battery status @ Pressure indication (5) Matrix field serves as menu and secondary display (7) MENU button Access the menu @ LIGHT button Turning the backlighting on and off (9) ZERO button The current pressure value will be set to "0" (rel.) or reference pressure (abs.) © Bar graph indicates the current pressure graphically @ Lock symbol:...

Open the catalog to page 8
Model CPG1500 - 9

WIKA-Cal calibration software Easy and fast creation of a high-quality calibration certificate The WIKA-Cal calibration software is used for generating calibration certificates or logger protocols for pressure measuring instruments and is available as a demo version for a cost-free download. A template helps the user and guides him through the creation process of a document. In order to switch from the demo version to a full version of the respective template, a USB stick with the template has to be purchased. The pre-installed demo version automatically changes to the selected full version...

Open the catalog to page 9
Model CPG1500 - 10

Calibration case with model CPG1500 precision digital pressure gauge and model CPP30 hand test pump, for pressures -0.95 ... +35 bar (-28 inHg ... +500 psi), consisting of: ■ Plastic service case with foam insert ■ Precision digital pressure gauge model CPG1500 ■ Pneumatic hand test pump model CPP30; -0.95 ... +35 bar (-28 inHg ... +500 psi) Available measuring ranges see specifications Basic version incl. pneumatic pressure generation For further specifications see data sheet CT 91.06 Calibration case with model CPG1500 precision digital pressure gauge and model CPP700-H hand test...

Open the catalog to page 10