1. Catalogs
  2. Mensor
  3. CPT6010 Digital Pressure Transducer
video corpo

CPT6010 Digital Pressure Transducer

CPT6010 Digital Pressure Transducer

CPT6010 Digital Pressure Transducer

Product catalog summary
Applications
  • High accuracy transfer standard
  • Internal pressure transducer in OEM devices
  • Pressure standard in test & calibration stands
  • Wind tunnels, Hydrology, Oceanography
  • Aerospace, Meteorology
Features
  • Accuracy: 0.020% FS
  • Single and dual calibration
  • Pressure Ranges: Absolute, Gauge, Bidirectional
  • Resolution: 1 ppm
  • Communication: RS-232 or RS-485
  • Reading Rate: 50 Hz
  • Material: 303 stainless steel housing
Description

The CPT6010 Digital Pressure Transducer is a high accuracy device for pressure measurements, featuring a low hysteresis silicon sensor with electronic compensation for pressure linearity. It offers 0.020% FS uncertainty and updates output at 50 readings per second.

Functional Flexibility

Utilizes RS-232 or RS-485 for communication, allowing remote operation up to 4,000 feet. Compatible with MS-DOS PCs for host control.

Specifications
  • Total Uncertainty: 0.020% FS
  • Calibration Interval: 180 days
  • Pressure Ranges: Absolute, Gauge, Bidirectional
  • Overpressure Limit: 150% FS
  • Compensated Temp. Range: 15 to 45 °C
  • Max. Transmission: 4000 feet (RS-485)
  • Mechanical Shock: 5g max
  • Weight: Approximately 12 ounces
  • Media Compatibility: 316L stainless steel
Standards and Compliance

Calibration program accredited by A2LA, complying with ISO/IEC 17025:2005 and ANSI/NCSL Z540-1-1994. All standards traceable to NIST. Mensor is ISO9001:2008 registered.

Contact Information

Mensor, 201 Barnes Drive, San Marcos, Texas 78666. Toll Free: 800-984-4200, Tel: 512-396-4200, Fax: 512-396-1820, Email: [email protected]

See more

Catalog excerpts

CPT6010 Digital Pressure Transducer-1

Testing and Calibration Technology Digital Pressure Transducer Model CPT6010 Applications ■ High accuracy transfer standard ■ Internal pressure transducer in OEM devices ■ Pressure standard in test & calibration stands ■ Wind tunnels ■ Hydrology ■ Oceanography ■ Aerospace ■ Meteorology Features ■ 0.020% FS accuracy ■ Single and dual calibration ■ Ranges: Absolute: 0 ... 7.5 psia up to 0 ... 6015 psia Gauge: 0 ... 5 psig up to 0 ... 6000 psig Bidirectional: -2.5 ... 2.5 psig up to -15 ... 6000 psig ■ Resolution to 1 ppm ■ Absolute or Gauge ■ Pneumatic or Hydraulic ■ Customer assigned pressure units ■ RS-232 or RS-485 communication ■ Multi-drop capability ■ Reading Rate 50 Hz ■ 303 stainless steel housing Description General The CPT6010 Digital Pressure Transducer is a self-contained pressure sensing device that provides high accuracy pressure measurements in both the single and dual calibration models. This transducer incorporates a low hysteresis silicon sensor with electronically compensated pressure linearity over the specified temperature range. The CPT6010 Transducer is characterized over the full pressure and temperature range to achieve 0.020% FS uncertainty. This uncertainty specification includes linearity, hysteresis, repeatability and temperature errors. Also featured is an output which is updated at a rate of 50 readings per second (20 ms). Applications The CPT6010 is used in OEM Applications where a high accuracy pressure sensing is required. It can also be used as a transfer standard or in pressure calibration and testing areas of production facilities. Functional Flexibility The CPT6010 Digital Pressure Transducer is a high accuracy pressure measurement component that uses either RS-232 or RS-485 to communicate with a host computer over long distances. Any MS-DOS compatible PC with an available serial output port can serve as the host controller. System designers will appreciate the flexibility offered by having highly accurate pressure transducers that are not tied to a front panel and which may be located remotely. For remote operation the transducer equipped with RS-485 can be located up to 4,000 feet from the host. A simple cable can accommodate both the power and the two-way communications requirements. Data Sheet CPT6010- PN 0019645001B • 03/2017 Page 1 of 2 Related Products: CPT6100 and CPT6180 Digital Pressure Transducer Pressure Systems

 Open the catalog to page 1
CPT6010 Digital Pressure Transducer-2

Total Uncertainty 0.020%FS. Total uncertainty (k=2) includes hysteresis, linearity, repeatability, reference standard, drift and temperature effects over the calibrated range for the calibration interval specified with periodic re-zeroing. 1LabVIEW® is a trademark of National Instruments Corporation. Multi-drop The maximum number of RS-485 Series 6000 Capacity transducers which can be connected to a single Case Size 1.75” wide x 6.0” long (4.45 x 15.24 cm), not including pneumatic and electrical. Weight Approximately 12 ounces (340.2 grams) Media All media compatible with 316L...

 Open the catalog to page 2

All Mensor catalogs and technical brochures

  1. WIKA Handbook

    436  Pages

  2. Calibration

    20  Pages

  3. Custom Systems

    20  Pages

  4. Model CPB5000

    12  Pages

  5. Model CPB3800

    15  Pages

  6. Model CPB3500

    9  Pages

  7. Model CTP5000

    6  Pages

  8. Model CPA8001

    8  Pages

  9. Model CPC8000

    8  Pages

  10. MODEL CPC7000

    9  Pages

  11. Model CPC6050

    8  Pages

  12. Model CPC4000

    8  Pages

  13. Model CPC2000

    6  Pages

  14. Model CPG500

    6  Pages

  15. Model CPG1500

    11  Pages

  16. CPG2300

    2  Pages

  17. CPA8001

    8  Pages

  18. CPA2501

    8  Pages

  19. CPC8000

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.