video corpo

CPA8001
8Pages

{{requestButtons}}

Catalog excerpts

CPA8001 - 1

Calibration Technology Air Data Test Set Model CPA8001 Data Sheet CPA8001 mensor Model CPA8001 - Air Data Test Set Applications ■ Altitude / vertical air speed calibration ■ Air speed calibration ■ Calibration of air data computers ■ Military, commercial, helicopter ■ Research and development laboratories Features ■ Uncertainty: ± 2.5 ft, ± 0.06 knots ■ RVSM Compliant ■ Ps/Qc or Ps/Pt removable transducer ■ One year calibration interval ■ Two year warranty ■ Automated zeroing function Description Application The CPA8001 Air Data Test Set (ADTS) is an air data controller designed for automated calibration and testing of altimeters, rate of climb indicators, airspeed indicators and air data computers. User Interface The high definition color touch screen and intuitive interface provides for simultaneous or asynchronous control of altitude/ altitude-rate, and/or airspeed/airspeed-rate. Entry of set points and system setting becomes second nature through the easy to understand buttons and menus. In addition, the user programmable sequence function provides storage and automated control of standard test procedures. Remote Operation Remote operation, via IEEE-488.2 (GPIB), Ethernet, RS232 or USB and command set emulation of non-Mensor ADTS devices makes the CPA8001 a valuable “drop-in” asset that can be used in production or calibration of air data instruments. Sensors & Control A dual (Ps/Pt or Ps/Qc) removable / interchangeable sensor is available, with an accuracy of 0.009% IS-50*. The requirements of RVSM specification are achieved with either sensor. User specified ranges are available for military, commercial or helicopter applications. The automated zeroing function adds another high accuracy absolute sensor within an automated zeroing system. This insures a high level of accuracy by automatically adjusting the zero for both channels. The percent of reading specification plus a proprietary control valve regulator, provides accurate, and stable control. Service & Calibration The CPA8001 can be supplied with an external “Calibration Sled” for remote calibration outside of the installed unit. Combined with Mensor’s world class service and support, the CPA8001 is the best solution to air data calibration applications. * See page 3 “Specifications” Data Sheet CPA8001 • PN 0019650001A • 01/2017 Page; 1 of 2

Open the catalog to page 1
CPA8001 - 2

Back Panel Page 2 of 8 Data Sheet CPA8001- PN 0019650001A • 01/2017

Open the catalog to page 2
CPA8001 - 3

(1) 0.009% IS-50 (InteMiScale-50) = 0.009% of reading from 100% FS to 50% FS and 0.009% of 50% FS from 0% to 50% FS for 365 days. (2) Measurement Uncertainty (k=2) includes hysteresis, linearity, repeatability, reference standard, drift and temperature effects over the calibrated range for the calibration interval specified, with periodic re-zeroing

Open the catalog to page 3
CPA8001 - 4

Stability of controlled pressure Units 0.002 % Span Stability of Controlled Avionics Units Airspeed (knots) Control Time 10 seconds to stable flag for a 10% pressure change into 150cc volume. Larger volumes can lengthen this time. Controlling to pressures less than 0.5 psia will lengthen this time. Source pressure requirements [media] 10% over the range of the channel’s transducer. [Clean, dry air (class 3 instrument air per ISO 8753) or nitrogen] Minimum controlled pressure 0.05% FS or 0.025 psi over exhaust pressure, whichever is greater. External volume recommendation Maximum: 60...

Open the catalog to page 4
CPA8001 - 5

Key Features Accuracy & Stability The Total Uncertainty specification for a standard CPA8001 falls well within the uncertainty required for RVSM. In addition, the patented Needle Valve Regulator provides a steady and precise pressure control output that simulates Altitude / Altitude Rate and Airspeed / Airspeed Rate into large volumes. Removable / Interchangeable Sensors Emulation / Drop-in Compatibility The CPA8001 remote communication software can receive and understand commands intended for other ADTS units, including the Mensor 8201 and 8205. This provides drop-in emulation of aging or...

Open the catalog to page 5
CPA8001 - 6

Main Screen The main screen — altitude, altitude rate, airspeed, airspeed rate, setpoint entry Ps Altitude button: Provides quick access to the setup parameters of the Ps-Altitude Channel including units of measure, limits, and stable window. Ps Rate button: Provides quick access to the setup parameters of the Ps-Rate channel including units of measure, limits, and stable window. Setpoint button: Used to enter a setpoint for altitude, altitude rate, or the setpoint in pressure mode. Qc Airspeed button: Provides quick access to the setup parameters of the Qc Airspeed channel including units...

Open the catalog to page 6
CPA8001 - 7

Setup Screens The CPA8001 setup screens provide a portal into the configuration of every aspect of the Air Data Test Set’s operating environment. The tab driven menu provides easy access to the settings for the general instrument functions, the remote communication settings, password protected calibration functions, programming and the settings for the Ps, Pt and Qc channels. Access to all of these areas is controlled via a user configured password hierarchy. General Settings ■ Mode ■ Language ■ Brightness ■ Volume ■ Sys. Info Remote Settings ■ Command Set ■ IEEE Settings ■...

Open the catalog to page 7
CPA8001 - 8

Scope of supply ■ CPA8001 Air Data Test Set ■ Power cable (6 ft.) with plug ■ Operating manual ■ A2LA accredited calibration certificate Options ■ Barometric reference (for QNH - Barometric adjustment to sea level) ■ 19" rack mounting Accessories ■ Remote calibration sled ■ Fittings Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. All standard Mensor products are provided with a calibration certificate traceable to NIST. The...

Open the catalog to page 8

All Mensor catalogs and technical brochures

  1. WIKA Handbook

    436 Pages

  2. Calibration

    20 Pages

  3. Custom Systems

    20 Pages

  4. Model CPB5000

    12 Pages

  5. Model CPB3800

    15 Pages

  6. Model CPG500

    6 Pages

  7. Model CPG1500

    11 Pages

  8. CPG2300

    2 Pages

  9. CPA2501

    8 Pages

  10. CPC8000

    8 Pages