Overview: The MAXIMATOR Nitrogen Charging Unit is designed for boosting nitrogen from gas cylinders up to 500 bar. It is used for testing oxygen systems, charging shock absorbers, hydraulic accumulators, and topping up nitrogen-filled actuators in aircraft.
Specifications:
  • Working pressure: Up to 500 bar
  • Calibrated gauges and transducers: 3.1
  • Operating medium: Nitrogen
  • Drive source: Compressed air and nitrogen
  • Dimensions: 450 x 550 x 500 mm
  • Weight: 29 kg (62 kg with case)
  • Pressure ratios available: 1:15 to 1:75
  • Air drive pressure: Min. 1 bar / Max. 7 bar
  • Connections: Pressure inlet BSP 1/2" / M16x1.5 (8S), Pressure outlet M16x1.5 (8S)
Features:
  • Mobile gas booster station for N2-charging applications
  • Stable flight case for safe transport
  • Extensive range of accessories available
Applications: The unit is suitable for various high-pressure applications, including testing equipment, hydraulics, and pneumatics.
Additional Information: All technical and dimensional information is subject to change. For more details, consult the factory. General terms and conditions of sale apply, including liability limitations.
See more

Catalog excerpts

Product Information - Nitrogen Charging Unit for gas bottle installation-1

M a x i m u m P r e s s u r e. High Pressure Technology • Testing Equipment Hydraulics • Pneumatics Nitrogen Charging Unit Release 10 / 2016 • MAXIMATOR • Product information N2 Charging Unit for gas bottle installation Mobile gas booster station for N2-charging applications This MAXIMATOR Nitrogen Charging Unit is specially designed for boosting of nitrogen directly from gas cylinders of up to 500 bar for testing applications of oxygen systems with nitrogen as well as charging of chock absorbers, hydraulic accumulators and to top up nitrogen-filled actuators in aircrafts. 3.1 calibrated gauges and transducers Operating medium nitrogen Extensive range of accessories available The station can be operated with both compressed air and also directly with nitrogen from a gas cylinder, thereby offering maximum mobility. Compressed air and nitrogen as drive source possible Stable flight case for safe transport Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including limitations of our liability, apply to all products and services sold. MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 (0) 3631 9533 – 0, Fax +49 (0) 3631 9533 – 5010

 Open the catalog to page 1
Product Information - Nitrogen Charging Unit for gas bottle installation-2

MAXIMATOR Maximum Pressure. High Pressure Technology • Testing Equipment Hydraulics • Pneumatics Typical P&ID Release 10 / 2016 • MAXIMATOR • Product information N2 Charging Unit for gas bottle installation Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including limitations of our liability, apply to all products and services sold. MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 (0) 3631 9533 - 0, Fax +49 (0) 3631 9533 - 5010, www.maximator.de, [email protected]