Catalog excerpts

M a x i m u m P r e s s u r e. High Pressure Technology • Testing Equipment Hydraulics • Pneumatics Liquified Gas Pumps LGP Serie
Open the catalog to page 1
Content / About Maximator Content: Seite: About MAXIMATOR 2 Anwendung und Funktion 3 Einsatz für entzündliche Fluide 4 Produktübersicht 5 MLGP Serie 6 – 7 SLGP Serie 8 – 9 GLGP Serie 10 – 11 Kältemittelübersicht 12 – 13 Weitere Leistungen - Hydraulik und Pneumatik 14 - Hochdrucktechnik und Prüftechnik 15 At your side, everywhere As an internationally leading company specialising in high-pressure technology, MAXIMATOR develops high-performance air driven liquid pumps and gas boosters for a variety of uses and applications. For decades we have supported well-known companies in the automotive...
Open the catalog to page 2
Application and Function Liquified Gas Pumps – the Maximator-Concept The Maximator LGP (Liquified Gas Pump) series was developed for use with refrigerants. The design of these pumps is based on the mode of operation of gas compressors in combination with proven highpressure pump technology. The technology has been optimized for the compression of liquid and gaseous fluids, so that the pumps of the LGP series can compress and convey both aggregate states. The SLGP and GLGP pumps are also optionally available with reduced stroke. On the one hand, this reduces the size of the pump and, on the...
Open the catalog to page 3
Selecting the right pump The following parameters are required for designing and selecting pumps: » Required operating pressure Desired pump capacity at operating pressure Available air drive pressure Fluid, Temperature of the fluid Ambient Temperature Information on requirements regarding size, weight, etc. Desired options and sealing materials Note: On request, the Maximator team will undertake the design and advise on the selection. There are special requirements for many applications; advice from experienced Maximator staff is therefore recommended. Versions & Options* Common...
Open the catalog to page 4
Product overview Flame arrester* available sealing materials** CR EPDM FFKM PTFE FKM HNBR standard * the flame arrester cannot be retrofitted. **The sealing material used in the standard can be found in the product name. Note: further technical information is available on the product data sheets. Sealing materials NBR – Nitrile rubber,good cold and deformation behavior at -30°C to 100°C, media compatibility: low, elastic. HNBR – hydrogenated nitrile rubber, good temperature behavior at -40°C to 140°C, media compatibility: low, abrasion resistant. EPDM – Ethylene propylene rubber, good...
Open the catalog to page 5
MLGP 7-NBR » Single-acting » With one air drive piston » Operating pressures of up to 70 bar (1.015 psi) » Formula for gas outlet pressure: pb = i * pl The compact and robust pumps of the MLGP series are available in a wide range of options to compress a broad spectrum of refrigerants. • Material: Pump heads made of aluminium, Pistons and valves made of stainless steel and NBR Sealing in standard • Standard models with bottom inlet • Suitable for air drive pressures from 1 to 10 bar (14.5 to 145 psi) • Seal version, e.g. FKM, HNBR, EPDM, CR for special fluids Order code: see media...
Open the catalog to page 6
Performance Graph for gaseous state • LTA-Option:Low-temperature modification for the high pressure and air drive section (-40°C bis 60°C) Order code: MLGP7 - LTA Drive pressure pL = 6 bar, Test fluid: Nitrogen, pA = gas inlet pressure Flow (lN/min) • LT-Option:Low-temperature modification for the high pressure section (-40°C up to 60°C) Order code: MLGP7 - LT Other options available on request. Performance Graph for liquid state Drive pressure = pL, Test fluid: Water-Oil-Emulsion approx. 1 - 10 cst 60 Flow (l/min
Open the catalog to page 7
SLGP 3-NBR » Double-acting » Single stage » With one air drive piston » Operating pressures of up to 52 bar (755 psi) » Formula for gas outlet pressure: pb = i * pl + pa The compact and robust pumps of the SLGP series are available in a wide range of options to compress a broad spectrum of refrigerants. • Material: Pump heads made of aluminium, Pistons and valves made of stainless steel and NBR Sealing in standard • Standard models with bottom inlet • Suitable for air drive pressures from 1 to 10 bar (14.5 to 145 psi) • Seal version, e.g. FKM, HNBR, EPDM, CR for special fluids - Order code:...
Open the catalog to page 8
SLGP 3-3-NBR » Double-acting » Two stage » With one air drive piston » Operating pressures of up to 52 bar (755 psi) » Formula for gas outlet pressure: pB = 3,4 * pL + 3,4/3,2 * pA Performance Graph SLGP 3* for gaseous state • FEC-Option: for dry compressed air or Drive pressure pL = 6 bar, Test fluid: Nitrogen, pA = gas inlet pressure nitrogen drive Order code: SLGP3 - FEC • LTA-Option:Low-temperature modification for the high pressure and air drive section (-40°C bis 60°C) Order code: SLGP3 - LTA Flow (lN/min) • LT-Option:Low-temperature modification for the high pressure section (-40°C...
Open the catalog to page 9
GLGP 5-NBR » Double-acting » Single stage » With one air drive piston » Operating pressures of up to 90 bar (1.305 psi) » Formula for gas outlet pressure: pb = i * pl + pa The compact and robust pumps of the GLGP series are available in a wide range of options to compress a broad spectrum of refrigerants. • Material: Pump heads made of aluminium, Pistons and valves made of stainless steel and NBR Sealing in standard • Standard models with bottom inlet • Suitable for air drive pressures from 1 to 10 bar (14.5 to 145 psi) • Seal version, e.g. FKM, HNBR, EPDM, CR for special fluids - Order...
Open the catalog to page 10
GLGP 5-5-NBR » Double-acting » Two stage » With one air drive piston » Operating pressures of up to 90 bar (1.305 psi) » Formula for gas outlet pressure: pB = 5,6 * pL + 5,6/5,2 * pA Performance Graph GLGP 5* for gaseous state • FEC-Option: for dry compressed air or Drive pressure pL = 6 bar, Test fluid: Nitrogen, pA = gas inlet pressure nitrogen drive Order code: GLGP 5 - FEC • LTA-Option:Low-temperature modification for the high pressure and air drive section (-40°C bis 60°C) Order code: GLGP 5 - LTA Flow (lN/min) • LT-Option:Low-temperature modification for the high pressure section...
Open the catalog to page 11All Maximator GmbH catalogs and technical brochures
-
Gas Booster and Air Amplifier
56 Pages
-
Valves-Fittings-and-Tubings
175 Pages
-
High-Pressure-Pumps
40 Pages
-
Maximator Image brochure
24 Pages
Archived catalogs
-
Maximator-Rental-Units
28 Pages
-
MAXIMATOR Gas Seals
4 Pages
-
Maximator Proportional Valve
7 Pages
-
MX-Compressors
24 Pages
-
Oil and Gas Technology
24 Pages
-
MAXIMATOR Valves Fittings Tubing
168 Pages
-
MAXIMATOR Gas Boosters
32 Pages
-
Air Amplifier Stations
12 Pages