B9600

B9600

B9600

Product catalog summary
Overview: The document provides detailed information on the B9000FXS and B9600FXS Uninterruptible Power Supply (UPS) systems by Magnus Power. These systems are designed to ensure high efficiency and reliability for critical applications, particularly in data centers and industrial settings.
Key Features:
  • Advanced Design: The B9000FXS and B9600FXS series feature low input current distortion, unity power factor input, and high overall efficiency. They incorporate IGBT input rectifier design with dual DSP and μC technologies for full digital control.
  • Online Double Conversion: This VFI (Voltage & Frequency Independent) topology provides complete isolation from mains power issues, ensuring stable and clean power output.
  • High Efficiency: The systems achieve over 95% efficiency in online double conversion mode, with smart online mode efficiency reaching up to 98%.
  • Transformer Protection: An output isolation transformer is included to enhance overload capabilities and reduce harmonics.
  • Parallel Capability: Up to 8 units can be connected in parallel, offering scalable power output and redundancy.
Technical Specifications:
  • Power Capacity: B9000FXS ranges from 60-300kVA, while B9600FXS ranges from 400-800kVA.
  • Input/Output: Nominal voltage options include 220/380, 230/400, 240/415 VAC Three Phase, with a frequency range of 50/60 Hz.
  • Efficiency: Certified by TUV Nord, the systems maintain efficiency levels above 95%.
  • Environmental Conditions: Operating temperature ranges from 0°C to +40°C, with storage temperatures from -10°C to +70°C.
User Interface and Options:
  • Features a graphical LCD display with standard communication ports including RS232, USB, and optional Web/SNMP, ModBus, and relay cards.
  • Options for parallel capacity, external bypass, and battery thermal probe are available.
Standards and Certification: The systems comply with CE, GOST, ETL, TUV standards, and adhere to IEC EN 62040-1, 62040-2, and 62040-3 for safety, EMC, and performance.
Conclusion: The B9000FXS and B9600FXS UPS systems by Magnus Power offer robust solutions for maintaining power quality and reliability in critical environments, with advanced features and high efficiency.
See more

Catalog excerpts

B9600-1

Uninterruptable Power Supplies B9000FXS / B9600FXS Main Features TÜ Online Double Conversion Smart Online Functionality Internal Galvanic Isolation Transformer Front access With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS systems regarded as the most critical infrastructure device in the data centre. Interruptions to electrical supply can cost organisations in excess of £100,000 per hour in lost revenues and productivity. The innovative design of the B9000FXS and B9600FXS range makes it one of the most technologically advanced UPS of its kind developed, the FXS series delivers an advanced combination of low input current distortion, unity power factor input, high overall efficiency and maximum load protection ensuring ultimate power quality. This sophisticated arrangement of features make this series ideal for critical applications where reliability and high performance are fundamental. In addition, the FXS range comprises an IGBT input rectifier design with dual DSP (Digital Signal Processing) and μC (Micro Controller) technologies, which provides full digital control. The FXS configuration guarantees the high quality output required by loads needing a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Systems. VFI (Voltage & Frequency Independent) Online Double Conversion topology provides built-in inverter galvanic protection, completely isolating the output of the UPS from mains power problems and further protection is achieved via an integral output isolation transformer. This advanced design offers an extensive range of user benefits, delivering high efficiency without compromising load protection. > 3 Year Warranty > High Efficiency > Transformer Protection Magnus Power. Vision House, 41 Brunel Road. Churchfield Industrial Estate. St. Leonards on Sea East Sussex. TN38 9RT power being restored. Although the information and recommendations on this document are presented in good faith and believed to be correct, Magnus Power makes no representations or warranties as to the completeness or accuracy of the information. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. in no event will Magnus Power be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from this datasheet or the products to which the information refers. Magnus Power does not warrant the accuracy or timeliness of the materials on this datasheet and has no liability for any errors or omissions in the materials. Email: [email protected] www.magnuspower.co.uk

 Open the catalog to page 1
B9600-2

Online Double Conversion Ultimate protection for all loads from data centres to industrial applications, the B9000/B9600FXS incorporates Online Double Conversion or VFI (Voltage and Frequency Independent) topology. In Online Double Conversion mode the output voltage and frequency are constantly generated by the inverter and so are isolated from any input power disturbances, spikes, dips and outages. For maximum protection, the batteries are positioned in the conversion circuit to ensure there is no break or switching should the need arise for them to power the load. This technology allows for...

 Open the catalog to page 2
B9600-3

Enhanced Compatibility with Mains & Generators The B9000FXS/B9600FXS use an IGBT input rectifier design, encompassing an advanced PFC (Power Factor Correction), which can keep input current THDi (Total Harmonic Distortion of the input) at a level of less than 3% and an input power factor within 1% of unity, even when only small loads are applied. Main benefits for the user: > The installation of the UPS is simplified > Upstream electrical supplies and cables do not have to be heavily overrated to cope with high harmonic distortion > Standby generators can typically be downsized by 40% > Users can...

 Open the catalog to page 3
B9600-4

B9000 FXS 60 - 300 kVA / B9600 FXS 400 - 800kVA Technical Specification Transformer Based In keeping with tradition and time proven reliability the B9000FXS andB9600FXS include an output isolation transformer as standard. The benefit of eliminating the possibility of high DC voltage destroying a valuable data centre in the case of a failing semi conductor, certainly outweighs the small additional footprint required. The transformer increases the overload capabilities, step load performance and short circuit clearing capability and with the addition of a bypass isolation transformer (which produces...

 Open the catalog to page 4
B9600-5

B9000 FXS 60 - 300 kVA Technical Specification POWER - KVA Dimensions WxDxH (mm) Weight (kg) Input/output connection Battery Hardwired (dual input) External, 300 cells INPUT Nominal voltage Voltage range Frequency Power factor Current distortion (THDi) OUTPUT Nominal voltage Frequency Voltage regulation PF acceptable without de-rating Overload capacity 220/380, 230/400, 240/415 VAC Three Phase -20%, +15% from nominal 50/60 Hz (45–65 Hz) 0.99 <3% 220/380, 230/400, 240/415 VAC Three Phase 50/60 Hz ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time Lagging to 0.9 leading 101–125% for...

 Open the catalog to page 5
B9600-6

B9600 FXS 400 - 800 kVA Technical Specification POWER - KVA Dimensions WxDxH (mm) Weight (kg) Input/output connection Hardwired (dual input) Nominal voltage Voltage range Power factor Current distortion (THDi) OUTPUT Nominal voltage Voltage regulation ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time PF acceptable without de-rating Overload capacity 101–125% for 10 min (on-line); 126–150% for 1 min (on-line); 1000% for 1 cycle (bypass) Efficiency - Online Double Conversion Eco-mode - Smart Online OPTIONS Parallel capacity/redundancy; External bypass; Battery thermal probe; Top cable...

 Open the catalog to page 6

All MAGNUS POWER catalogs and technical brochures

  1. E2001.e

    2  Pages

  2. B8000

    4  Pages

  3. B400

    2  Pages

  4. B500R

    3  Pages

  5. B200

    1  Page

  6. B9000

    6  Pages

  7. B500

    3  Pages

  8. B60

    1  Page

  9. ME3

    4  Pages

  10. LP3

    1  Page

  11. ME1

    4  Pages

  12. LP1

    1  Page

  13. LF3-400

    1  Page

  14. LF1-400

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.