B8000
1 / 4Pages

Catalog excerpts

B8000 - 1

Uninterruptable Power Supplies With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical infrastructure device in the data centre. Interruption to electricalsupply can cost organisations in excess of £100,000 per hour in lost revenues and productivity. The innovative design of the B8000FXS makes it one of the most technologically advanced UPS of its kind. The FXS series delivers an advanced combination of low input current distortion, unity power factor input, high overall efficiency and maximum load protection ensuring ultimate power quality. Front Access This sophisticated arrangement of features make this seriesi deal for applications where reliability and high performance are fundamental. In addition, the FXS range comprises an IGBT input rectifier designwith dual DSP (Digital Signal Processing) and μC (Micro Controller)technologies, which provides full digital control. The FXS configuration guarantees high quality output required by loads requiring a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Systems. VFI (Voltage & Frequency Independent) Online Double Conversion topology, provides built-in inverter galvanic protection, completely isolating the output of the UPS from mains power problems. This advanced design offers an extensive range of user benefits including high efficiency without compromising load protection. Back Feed Protection Online Double Conversion B8000FXS Main Features Online Double Conversion Topology Smart Online Function - Scalable up to 8 units in parallel Temperature Compensated Battery Charging High Level Diagnostics via LCD Screen Dual DSP Controller Enhanced Generator Compatibility Ultimate protection for all loads from computer rooms and small datacentres to industrial applications, the B8000FXS incorporates Online Double Conversion or VFI (Voltage and Frequency Independent) topology. In online double conversion mode the output voltage and frequency are constantly generated by the inverter and so are isolated from any input power disturbances, spikes, dips or outages. For maximum protection the batteries are positioned in the conversion circuit to ensure there is no break or switching should the need arise for them to power the load. This technology allows for an extremely wide range of input voltage and frequency, whilst enabling the UPS to control perfect output conditions without having to use battery power. Magnus Power. Vision House, 41 Brunel Road. Churchfield Industrial Estate. St. Leonards on Sea East Sussex. TN38 9RT power being restored. Although the information and recommendations on this document are presented in good faith and believed to be correct, Magnus Power makes no representations or warranties as to the completeness or accuracy of the information. Information is supplied upon the condition that the persons receiving same will make their own determination as to its suitability for their purposes prior to use. in no event will Magnus Power be responsible for damages of any nature whatsoever resulting from the use of or reliance upon information from this datasheet or the products to which the information refers. Magnus Power does not warrant the accuracy or timeliness of the materials on this datasheet and has no liability for any errors or omissions in the materials. Email: magnuspower.sales@akersolutions.com www.magnuspower.co.uk

Open the catalog to page 1
B8000 - 2

As the AC input is always converted to DC and then converted back to AC, the double conversion process provides complete electrical isolation of the output from the input, iunless the inverter is switched off the critical load will never see the raw mains power. Enhanced Compatibility with Mains & Generators The B8000 FXS uses an IGBT input rectifier design, encompassing an advanced PFC (Power Factor Correction), which maintains input current THDi (Total Harmonic Distortion of the input) at a level of less than 3% and an input power factor within 1% of unity, even when only small loads are...

Open the catalog to page 2
B8000 - 3

B8000 FXS Technical Specification UPS Block Diagram Dedicated to traditional UPS design, we know that a UPS operating in true online double conversion mode (VFI) offers a higher level of protection over Line Interactive(VI) or Offline (VFD) topologies. Historically this has resulted in poor operating efficiency, however, investment at component level in the design of B8000 FXS means that the FXS range can perform with overall efficiency levels of greater than 95% through mid-range loadings. This impressive operational rating provides the user with true efficiency without compromise. >...

Open the catalog to page 3
B8000 - 4

with battery Input/output connection Battery Hardwired (dual input) Internal or external, 372 cells Hardwired (optional dual input) External, 372 cells Voltage range Power factor Current distortion (THDi) OUTPUT Nominal voltage Frequency Voltage regulation Lagging to 0.9 leading 101–125% for 10 min (on-line); 126–150% for 1 min (on-line); 500% for 1 cycle (bypass) Efficiency EPS (Eco-mode) Options 50/60 Hz ±1% static; ± 2% dynamic 100% load change, <10 ms recovery time PF acceptable without de-rating Overload capacity >95% >98% Parallel capacity/redundancy; isolation transformer; external...

Open the catalog to page 4

All MAGNUS POWER catalogs and technical brochures

  1. E2001.e

    2 Pages

  2. B400

    2 Pages

  3. B9600

    6 Pages

  4. B500R

    3 Pages

  5. B200

    1 Pages

  6. B9000

    6 Pages

  7. B500

    3 Pages

  8. B60

    1 Pages

  9. ME3

    4 Pages

  10. LP3

    1 Pages

  11. ME1

    4 Pages

  12. LP1

    1 Pages

  13. LF3-400

    1 Pages

  14. LF1-400

    1 Pages