Technical Documentation LTG High Performance Tangential Fans Series VQ Impeller diameter 200 to 1000 mm
Open the catalog to page 1© LTG Aktiengesellschaft · Grenzstraße 7 · 70435 Stuttgart · Germany Tel. +49 (711) 8201-0 · Fax +49 (711) 8201-696 · [email protected] · www.LTG.net Former editions are invalid · Subject to technical modifications
Open the catalog to page 2Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Many production processes require a linear extended and absolutely even distribution of air or other gases to the working area. Because of their special design, tangential fans meet this requirements in the best possible way. The rigid design and the use of high quality materials secure a long service life. By the working principle, that does away with additional baffles and vanes and the space saving design, the use of tangential fans is very economic. Space saving due to a 90_ airflow deflection. The fan width can be exactly...
Open the catalog to page 3nAIR TECH Type VQNService Conditions gas temperatures: -25 °Cupto+40 °C permissible bearing temperatures: Tangential fan with shaft end on the drive side. Rigid welded casing with duct connection flange for suction side and discharge side. The impeller is both sides bedded in self-aligning ball bearings in pillow block frames. Bearing design life is 20000 houres (90% statistical). Both bearings have grease nipples. The impeller is balanced to grade Q 6.3 of VDI 2060. With the suction opening on top, viewed against the discharge opening, the drive side shaft end can be right hand or left hand....
Open the catalog to page 4Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Acoustics, Greasing Intervals The catalogue data are based on: The specific mass of air is: ρ=1.2 kg/m3. The performance data are laboratory tested according to VDI 2044 with unobstructed air flow Acoustical data The acoustical data are for discharge side, tested in a reverberant field. The A-weighted sound power level LWA can be transformed into a A-weighted sound pressure level by the equation LpA = LWA - 10 log S/1 m2 For this the exact total applicable panel area S ean be used. Unweighted sound power level LW [dB] The sound...
Open the catalog to page 5Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 200 mm Type The indicated dimensions are for the maximum rated power for each nominal length. Dimensions for lower rated motor power on request. © LTG Aktiengesellschaft ■ GrenzstraUe 7 ■ 70435 Stuttgart ■ Germany Former editions are invalid ■ Subject to technical modifications
Open the catalog to page 6Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 200 mm Fan Curves mean discharge face velocity c [m/s] air volume per meter impeller length Vm [m3/(sSm)] rated speed n [rpm] up to impeller length L [mm] air volume per meter impeller length Vm [m3/(hSm)] velocity pressure pdyn [Pa] * The shaft power consumption shown in this diagram does not include belt drive losses. © LTG Aktiengesellschaft · Grenzstraße 7 · 70435 Stuttgart · Germany Tel. +49 (711) 8201-0 · Fax +49 (711) 8201-696 · [email protected] · www.LTG.net Former editions are invalid · Subject to technical...
Open the catalog to page 7Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 250 mmDimensions, Technical Data Type The indicated dimensions are for the maximum rated power for each nominal length. Dimensions for lower rated motor power on request. © LTG Aktiengesellschaft ■ GrenzstraUe 7 ■ 70435 Stuttgart ■ Germany Former editions are invalid ■ Subject to technical modifications
Open the catalog to page 8Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 250 mm Fan curves mean discharge face velocity c [m/s] air volume per meter impeller length Vm [m3/(sSm)] speed rated speed n [rpm] n [rpm] up to impeller length L [mm] air volume per meter impeller length Vm [m3/(hSm)] velocity pressure pdyn [Pa] * The shaft power consumption shown in this diagram does not include belt drive losses. © LTG Aktiengesellschaft · Grenzstraße 7 · 70435 Stuttgart · Germany Tel. +49 (711) 8201-0 · Fax +49 (711) 8201-696 · [email protected] · www.LTG.net Former editions are invalid · Subject...
Open the catalog to page 9Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 315 mmDimensions, Technical Data Type The indicated dimensions are for the maximum rated power for each nominal length. Dimensions for lower rated motor power on request. © LTG Aktiengesellschaft ■ GrenzstraUe 7 ■ 70435 Stuttgart ■ Germany Former editions are invalid ■ Subject to technical modifications
Open the catalog to page 10Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 315 mm Fan curves mean discharge face velocity c [m/s] rated speed n [rpm] up to impeller length L [mm] air volume per meter impeller length Vm [m3/(sSm)] air volume per meter impeller length Vm [m3/(hSm)] velocity pressure pdyn [Pa] The shaft power consumption shown in this diagram does not include belt drive losses. © LTG Aktiengesellschaft · Grenzstraße 7 · 70435 Stuttgart · Germany Tel. +49 (711) 8201-0 · Fax +49 (711) 8201-696 · [email protected] · www.LTG.net Former editions are invalid · Subject to technical...
Open the catalog to page 11nAIR TECH The indicated dimensions are for the maximum rated power for each nominal length. Dimensions for lower rated motor power on request. © LTG Aktiengesellschaft ■ GrenzstraUe 7 ■ 70435 Stuttgart ■ Germany Former editions are invalid ■ Subject to technical modifications
Open the catalog to page 12Technical brochure • High Performance Tangential Fans VQN, VQH, VQT Impeller Diameter 400 mm Fan curves mean discharge face velocity c [m/s] air volume per meter impeller length Vm [m3/(sSm)] speed n [rpm] rated speed n [rpm] up to impeller length L [mm] air volume per meter impeller length Vm [m3/(hSm)] velocity pressure pdyn [Pa] The shaft power consumption shown in this diagram does not include belt drive losses. © LTG Aktiengesellschaft · Grenzstraße 7 · 70435 Stuttgart · Germany Tel. +49 (711) 8201-0 · Fax +49 (711) 8201-696 · [email protected] · www.LTG.net Former editions are invalid · Subject...