Let‘s realize the potential of air for a sustainable world Technical brochure Pressure controller with air flow feedback DRFactive The DRFactive is ideal for applications with limited space, low air velocities, high measurement accuracy requirements, and when pressure control and air flow measurement need to be combined in a single unit. Differential pressure control up to 1000 Pa Air leakage rate according to DIN EN 1751, class 4 (DN 100/125: class 3) Housing tightness class C according to DIN EN 1751 Short installation lengths due to measurement at the damper blade Low pressure losses: energy savings, quiet operation Large measuring range: 1...10 m/s Measuring accuracy: ±5% (Vnom ) to ±15% (Vmin ) Retrofittable insulation shell
Open the catalog to page 1LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Contents Page Area of application, structure, mode of operation, features, materials/surfaces, options, accessories 3 Air flow ranges, minimum pressure differences, function 4 Ventilation systems with pressure controllers 8 Nomenclature, order code 9 Technical data, controller components 10 © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical changes.
Open the catalog to page 2LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Application range - DRFactive pressure controller for line pressure control in air pipes of ventilation and air conditioning systems - Ensures equal inlet pressure at downstream components (e.g., air flow controllers, induction units, air diffusers) - Measured value can be used for fan speed control (bad point control) -Air flow measurement for recording and feedback of the air air flow. Feedback signal can be used for display or master-slave applications - Optional: Full shut-off possible - Housing with...
Open the catalog to page 3LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Vmin - Minimum air flow = lower control limit Vnom - Nominal air flow Apmin - Minimum pressure loss How does the DRFactive work? DRFactive makes it possible to regulate pressure and measure air flow precisely at the same time. The advantage is that, with open extract air, the actual air flow can be measured and extracted almost identically. Two electrical components are integrated for this purpose: one measures the air flow directly at the damper, while the other measures the pressure at a freely selectable...
Open the catalog to page 4LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Installation, placement With duct or duct pressure control, the pressure is measured relative to the ambient pressure. One connection of the sensor remains open („+“ for extract air, „–“ for supply air), while the other connection is connected to the measuring point. The pressure at the measuring point is controlled in the direction of air flow behind the DRFactive in the supply air or in front of the DRFactive in the exhaust air. The pressure tapping point must be connected to the differential pressure...
Open the catalog to page 5LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Dimensions, weight Type DRFactive/.../-/L/GUAC, without insulation shell Type DRFactive/.../D/L/GUAC, with insulation shell © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical changes.
Open the catalog to page 6LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical changes.
Open the catalog to page 7LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Ventilation systems with pressure controllers (example) Pressure controller DRFactive, with integrated air ow measurement Variable air ow controller VRFactive Pressure measuring point Variable air ow controller VREactive Air diffuser combination LWK with integrated sound insulation Air diffuser combination LWK with integrated sound insulation Air diffuser combinations LWK with integrated sound-absorbing baffle Office room Office room Meeting room Application example DRFactive: Supply air pressure controller...
Open the catalog to page 8LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Please specify when ordering: Air flow feedback signal: Mode 0...10 V or 2...10 V - Modbus or analog control Without this information, the following factory settings will be delivered: - Mode 0...10 V - Analog control Ordering example DRFactive 600x200/S/D/GUAC, Pmin = 150 Pa, Pmax = 300 Pa, Mode 2...10 V, analog control © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical...
Open the catalog to page 9LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical changes.
Open the catalog to page 10LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular © LTG Aktiengesellschaft, Grenzstrasse 7, 70435 Stuttgart , Germany Tel. +49 711 8201-0, Fax +49 711 8201-720, [email protected], www.LTG-AG.com Previous editions are invalid. Subject to technical changes.
Open the catalog to page 11LTG Comfort Air Technology | Technical brochure Pressure controller DRFactive, rectangular Δptotal = 100 Pa Flow velocity [m/s] Nominal width B [mm] Nominal height H [mm] Airborne sound transmission without silencer - Total pressure difference - Center frequency of the octave bands - Sound power level - Sound power level, A-weighted - Sound pressure level, A-weighted Conversion to other sizes is carried out at the same choke point from flow velocity and pressure loss using the ΔL values in the following table. The values refer to the respective nominal height H. LW Oct = LW Table + ΔL LWA = LWA...
Open the catalog to page 1214 Pages
46 Pages
10 Pages
11 Pages
8 Pages
14 Pages
16 Pages
16 Pages
18 Pages
16 Pages
17 Pages
10 Pages
18 Pages
12 Pages
16 Pages
8 Pages
2 Pages