Product catalog summary
Overview: The document provides detailed technical specifications and features of the QF18-Series Miniature Circuit Breakers, which utilize hydraulic-magnetic technology and are unaffected by ambient temperature, maintaining 100% rated current capability.
Features:
  • Available in one, two, three pole, 1+N, and 3+N configurations.
  • Compliant with VC 8036 and tested to SANS 556-1 standards.
  • Approved by VDE, EAC, CCC, and CE certified.
  • Current ratings range from 1 A to 63 A with a wide range of time delays and operating currents.
  • Precision tripping characteristics with trip indication and mid-trip position.
  • DIN mountable in grey shells, suitable for electrical isolation.
Applications: Suitable for AC branch circuit protection, telecom/datacom equipment, lighting control, UPS equipment, alternative energy, mobile power generation, railway signaling, residential, and industrial equipment.
Technical Data:
  • Operating voltages: 240 Vac and 415 Vac.
  • Ultimate short-circuit breaking capacity (Icu): 5 kA or 6 kA depending on approvals.
  • Ambient operating temperature: -40 °C to +85 °C.
  • Endurance: 10,000 operations (1,500 with current, 8,500 without current).
  • Dielectric strength: 1000 - 2000 Vac for one minute.
  • Rated impulse withstand voltage: 4 kV.
  • Weight: 120 g per pole, 180 g with auxiliary.
Ordering Information: The document provides a detailed breakdown of the ordering code structure, including frame type, switch/neutral options, auxiliary/trip alarm, number of poles, module width, mounting options, time delays, current ratings, and other customizable options.
Time Delay Curves: The document includes tripping characteristics curves for different time delay settings, illustrating the relationship between percentage of rated current and tripping time.
Internal Impedance: A graph is provided showing the internal impedance versus current rating, indicating minimum and maximum impedance values across different amp ratings.
Contact Information: Contact details for CBI-electric in Australia, South Africa, and the USA are provided for further inquiries.
See more

Catalog excerpts

QF(18)- Series Miniature Circuit Breakers-1

QF(18) - Series Miniature Circuit Breakers AC circuit breaker Hydraulic-magnetic technology 100% rated current capability, independent of ambient temperature One, two, three pole, 1+N and 3+N VC 8036 compliant SANS 556-1 tested VDE, EAC and CCC approved, CE certified Ratings 1 A to 63 A Wide range of time delays & operating currents Precision tripping characteristics Trip indication with mid-trip position Can be switched on immediately after tripping DIN mount product in grey shells Suitable to use for electrical isolation AC branch circuit protection (IEC / EN 60947-2) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Auxiliary Switch: Features Optional Accessories Factory fitted Attached to right hand side of the circuit breaker Compact 6.5 mm width IEC 60947-5-1 110 Vdc, 0.5 A; 240 Vac, 6A Handle lock ( QFAP001) Surface mounting clips (2096001) Busbar (2121381) Hydraulic-Magnetic Circuit Breakers are unaffected by ambient temperature and carries 100% rated current QF18-SER

 Open the catalog to page 1
QF(18)- Series Miniature Circuit Breakers-2

QF(18) - Series Miniature Circuit Breakers Technical Data Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Ultimate S/C Breaking Capacity (Icu) Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Ultimate S/C Breaking Capacity (Icu) Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Ultimate S/C Breaking Capacity (Icu) Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Ultimate S/C Breaking...

 Open the catalog to page 2
QF(18)- Series Miniature Circuit Breakers-3

QF(18) - Series Miniature Circuit Breakers Technical Data Product Type Ambient Operating Temperature Mounting Options Time Delay Curves Endurance Dielectric Strength Rated Impulse Withstand Voltage Weight Altitude Shock Vibration Flammability Toxicity Pollution Degree QF(18) -40 °C to +85 °C DIN rail, surface mount 1, 2, 9 10000 operations; 1500 with current, 8500 without current (IEC 60947-2 Clause 7.2.4.2)* 1000 - 2000 Vac for one minute (IEC 60947-2 Clause 8.3.3.3)* 4 kV (IEC 60947-2 Clause 8.3.3.2) 120 g per pole, 180 g with auxiliary (unpacked) Certification tests done at altitude ≈ 2000...

 Open the catalog to page 3
QF(18)- Series Miniature Circuit Breakers-4

QF(18) - Series Miniature Circuit Breakers Long Code Example Code: QF---A-3(18)-D-2-50A-----Group Long Code Switch / neutral Auxiliary switch Triple pole Medium delay curve 2 Shunt trip Special requirement Special termination Customer specific Ordering Information Group 1: Frame Type Miniature circuit breaker Green handle Green handle Comments Group 3: Auxiliary / Trip Alarm Auxiliary switch (1 x Aux in 1 module) 6.5 mm module fitted on right-hand side Single pole Double pole Triple pole Four pole Group 5: Module Width DIN mount supplied in grey body only - 45 mm escutcheon Group 7: Time Delays...

 Open the catalog to page 4
QF(18)- Series Miniature Circuit Breakers-5

QF(18) - Series Miniature Circuit Breakers Ordering Information continues Group 10: Shunt Trip Group 11: Special Requirement Group 12: Special Termination Group 13: Customer Specific For options not listed, please contact CBI Data Sheet Page 5 of 10

 Open the catalog to page 5
QF(18)- Series Miniature Circuit Breakers-6

QF(18) - Series Miniature Circuit Breakers Time Delay Curve 100000 QI Info Info gained from curve Time (seconds) Percentage of rated current Data Sheet Page 6 of 10

 Open the catalog to page 6
QF(18)- Series Miniature Circuit Breakers-7

QF(18) - Series Miniature Circuit Breakers Time Delay Curve 100000 QI Info Info gained from curve Percentage of rated current Time (seconds) Data Sheet Page 7 of 10

 Open the catalog to page 7
QF(18)- Series Miniature Circuit Breakers-8

QF(18) - Series Miniature Circuit Breakers Time Delay Curve 100000 Time (seconds) Percentage of rated current * The published time delay curves are generated at 30 oC ambient temperature with the circuit breaker mounted in the up-right position. The “must hold”, “must trip” and “instantaneous trip” current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Data Sheet Page 8 of 10

 Open the catalog to page 8
QF(18)- Series Miniature Circuit Breakers-9

QF(18) - Series Miniature Circuit Breakers Internal Impedance vs Current Rating Q-Range impedance values Data Sheet Page 9 of 10

 Open the catalog to page 9
QF(18)- Series Miniature Circuit Breakers-10

QF(18) - Series Miniature Circuit Breakers Outline Dimensions: DIN mount Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission....

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.