Overview: The QA13 Series is a range of low voltage AC circuit breakers utilizing hydraulic-magnetic technology. These breakers are designed for various applications, including telecom, lighting control, UPS, and alternative energy equipment. They are compliant with VC 8036 and SANS 556-1 standards, VDE approved, and CE certified.
Specifications:
  • Available in one to four poles, including 1+N and 3+N configurations.
  • Current ratings range from 5 to 60 A, with specific ratings subject to certification.
  • Operating voltages are 240 Vac and 415 Vac.
  • Interrupting capacity is 3 kA for circuit breakers and 2.5 kA for switch disconnectors.
  • Endurance of 10,000 operations, with 1,500 electrical at rated current and voltage.
  • Operating temperature range from -40 °C to +85 °C.
Features:
  • 100% rating capability, independent of ambient temperature.
  • Ultra-compact design with a 13 mm wide module.
  • Trip indication with mid-trip position and immediate reset after overload.
  • Suitable for electrical isolation and easy installation onto busbars.
Optional Accessories:
  • Auxiliary switch, trip alarm, and combo options available.
  • UL 489 listed and IEC 60947-5-1 approved for auxiliary switches and trip alarms.
Technical Data:
  • Dielectric strength of 1480 V for single pole and 1830 V for multi-pole configurations.
  • Weight is 102 g per pole, 160 g with auxiliary, depending on rating.
  • Shock resistance of 16 G and vibration resistance of 1 G.
  • Flammability and toxicity ratings ensure safety in various environments.
Applications: The QA13 Series is suitable for residential, industrial, and mobile power generation equipment, as well as railway signaling equipment.
Contact Information: CBI-electric has offices in Australia, South Africa, and the USA, providing contact details for sales and support.
See more

Catalog excerpts

QA(13) - Series Miniature Circuit Breakers-1

QA(13) - Series Miniature Circuit Breakers Mini Rail Mount 1 pole Mini Rail Mount 2 pole Mini Rail Mount 3 pole Mini Rail Mount 3+N AC circuit breaker Hydraulic-magnetic technology One, two, three, four pole, 1+N and 3+N 100% rating capability, independent of ambient temperature VC 8036 compliant (SANS 556-1) VDE approved, CE certified Ratings 5 to 60 A (subject to certification) Precision tripping characteristics Ultra compact – 13 mm wide module Trip indication with mid-trip position Reset immediately after overload Mini rail mount product in black shells Suitable to use for electrical isolation Shell designed for easier installation onto busbar Auxiliary Switch,Trip Alarm & Combo: Features • • • • • • • • • Optional Accessories Auxiliary switch Auxiliary switch + trip alarm Trip alarm AC and DC voltages UL 489 listed (auxiliary switch: 6 A 250 Vac, 0.5 A 80 Vdc) IEC 60947-5-1 approved (auxiliary switch: 6 A 240 Vac, 0.5 A 110 Vdc; trip alarm: 6 A 240 Vac, 0.5 A 110 Vdc) Factory fitted Attached to right hand side of circuit breaker Compact 6.5 mm width AC branch circuit protection (IEC / EN 60947-2) Switch disconnector (SANS 60947-3) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Handle lock Surface mounting clips Busbar Escutcheon blank Safety blank

 Open the catalog to page 1
QA(13) - Series Miniature Circuit Breakers-2

QA(13) - Series Miniature Circuit Breakers Technical Data Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Specific Ratings (Verify Certification) Interrupting Capacity Product Type Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Specific Ratings (Verify Certification) Interrupting Capacity Product Type Approvals Number of Poles Operating Voltages Current Rating Auxiliary Switch Trip Alarm Auxiliary Switch / Trip Alarm Combo Data Sheet Page 2 of 6 Switch Disconnector SANS 60947-3 2 3 415 Vac 63 A...

 Open the catalog to page 2
QA(13) - Series Miniature Circuit Breakers-3

QA(13) - Series Miniature Circuit Breakers Technical Data Product Type Operating Temperature Range Mounting Options Time Delay Curves Endurance Dielectric Strength Weight Humidity Altitude Shock Vibration Flammability Toxicity Pollution Degree Breaker QA 1 Pole to 4 Pole QA(13) -40 °C to +85 °C Mini rail, surface mount 3 10000 operations - 1500 electrical at rated current and voltage (IEC 60947-2) 1480 V (single pole) / 1830 V (multi pole), 50 Hz for one minute after testing 102 g per pole, 160 g with auxiliary (depending on rating) (unpacked) 35 to 85% relative Certification tests done at altitude...

 Open the catalog to page 3
QA(13) - Series Miniature Circuit Breakers-4

QA(13) - Series Miniature Circuit Breakers Long Code Example Code: QA-----3(13)-MR-3-15A-----1 Switch / neutral Long Code Group 1: Frame Type 13 mm wide miniature circuit breaker Group Requirement Auxiliary + Triple pole trip alarm - Group 2: Code Switch/Neutral - Mini rail Short delay curve 3 Shunt trip Overload poles do not have any further coding Green handle Green handle Use this code if no auxiliary used 6.5 mm module fitted on right-hand side Double auxiliary switch (2 x Aux in 1 module) 6.5 mm module fitted on right-hand side Trip alarm (1 x trip alarm in 1 module) 6.5 mm module fitted...

 Open the catalog to page 4
QA(13) - Series Miniature Circuit Breakers-5

QA(13) - Series Miniature Circuit Breakers Time Delay Curves 1500 Tripping Time (Seconds) % Rated Current * The published time delay curves are generated at 30oC ambient temperature with the Circuit Breaker mounted in the up-right position. The “must hold”, “must trip” and “instantaneous trip” current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Internal Impedance vs Current Rating Q-Range impedance values Data Sheet

 Open the catalog to page 5
QA(13) - Series Miniature Circuit Breakers-6

QA(13) - Series Miniature Circuit Breakers Outline Dimensions: Mini Rail © 2016.09 CBI (Pty) Ltd. All Rights Reserved. Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is...