Specifications:
  • Signal Types: Includes voltage, frequency, and digital (fieldbus/Ethernet).
  • Connector Types: Features 6-pin and 12-pin Binder connectors.
  • Cable Type: Utilizes LiYCY transparent shielded cables.
  • Temperature Range: Operates between -10°C to +70°C.
  • Protection Class: Rated at IEC/EN 60529 IP40.
  • Bending Radius: Approximately 10 times the outside diameter.
Installation Guidelines:
  • Avoid parallel cable placement with power/control lines to reduce electromagnetic interference.
  • Use grounded armored conduits near electromagnetic fields.
  • Minimize excess cable lengths and avoid closed loops.
  • Lay sensor cables in bifilar form to decrease inductive areas.
Product Variants and Accessories:
  • Offers various cable lengths, including 2.5 meters, 5 meters, and customizable options.
  • Provides specific material numbers for different configurations.
  • Includes accessories like coupling sockets and amplifiers for strain gage sensors.
Recommendations:
  • Use original Kistler cables for optimal performance.
  • Consult data sheets for pin allocation and evaluation unit compatibility.
Torque Sensors and Cables: Lists different torque sensor types (e.g., 4510B, 4520A) with compatible cables and connectors (e.g., 7-pin, 12-pin).
General Technical Data: Covers protection classes (IP40, IP54, IP67), temperature ranges, and bending radius requirements.
Accessories: Details coupling sockets and SensorTool Type 4706A, along with couplings Type 2300A to 2305A.
Legal and Contact Information: Includes a disclaimer on technical changes and liability, with contact details for Kistler Group in Switzerland.
See more

Catalog excerpts

Cable Connection for Torque Sensors-1

Accessories Cable and Measuring Chains Cable Connection for Torque Sensors In order to integrate sensor technology into a given application, it is advisable to clarify these points in advance; this will provide the basis for selecting the relevant components to generate the measuring chain: • Type of signal: voltage, frequency, digital (fieldbus/Ethernet) • Number of pins of the selected output • Pin allocation for sensor and evaluation unit (see data sheet) Description When installing the cables, make sure that the maximum permitted cable length is not exceeded. It is advisable to use original Kistler cables only. Most torque sensors based on strain gage technology already have an internal amplifier. The sensors can be connected with the appropriate evaluation unit, or directly with the PLC in some cases. For the analysis of dedicated XY processes (such as torquerotation angle monitoring), the maXYmos family is highly suitable thanks to its user-friendly operation and wide variety of interfaces (Y-channel: piezo, strain gage, ± 10 V; X-channel: potentiometer, ± 10 V, incremental). Laying of the Measuring Cable: • Do not lay parallel to power lines or control lines • Not in the vicinity of heavy electro-magnetic fields, e.g. transformers, welding devices, contactors, motors etc • If this cannot be avoided, lay the measuring cable in a grounded armored conduit • Excess lengths should be prevented. If it isn’t possible to avoid, then do not lay excess lengths in closed loops Measuring cable Cable tunnel The cable length are available in 2.5 meter / 5 meter or customized length. Risk to couple in EMC noises into the measuring sensor cable Measuring cable Cable tunnel To reduce the inductive areas it’s recommended to laying the measuring sensor cable in bifilar form Page 1/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered trademark of

 Open the catalog to page 1
Cable Connection for Torque Sensors-2

Accessories Cable Cable and Connection Torque Sensor Type 4501A... Monitor & Control Type 5867A... Length (m) 5 variable Page 2/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered trademark of Kistler Holding AG.

 Open the catalog to page 2
Cable Connection for Torque Sensors-3

Accessories Cable Cable and Connection Torque Sensor Type 4501A... Monitor & Control General Technical Data Protection Class IEC/EN 60529 LiYCY transparent shielded Temperature range Bending radius approx. 10x outside diameter Data sheet see www.kistler.com Accessories Coupling socket 6 pin Amplifier for strain gage sensors Page 3/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408...

 Open the catalog to page 3
Cable Connection for Torque Sensors-4

Accessories Cable Cable and Connection Torque Sensor Type 4502A... Monitor & Control Page 4/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered trademark of Kistler Holding AG.

 Open the catalog to page 4
Cable Connection for Torque Sensors-5

Accessories Cable Cable and Connection Torque Sensor Type 4502A... Monitor & Control General Technical Data Protection Class IEC/EN 60529 LiYCY transparent shielded Temperature range Bending radius approx. 10x outside diameter Data sheet see www.kistler.com Accessories Type Page 5/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax...

 Open the catalog to page 5
Cable Connection for Torque Sensors-6

Accessories Cable Cable and Connection Torque Sensor Type 4503... 12 pin to CoMo Torque (Voltage) 4503... 4503... 12 pin to CoMo Torque (Frequency) Length (m) 4503... 2,5 4503... variable Monitor & Control This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered trademark...

 Open the catalog to page 6
Cable Connection for Torque Sensors-7

Accessories Cable Cable and Connection Torque Sensor Type 4503... Monitor & Control Measuring range changeover Page 7/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered trademark of Kistler Holding AG.

 Open the catalog to page 7
Cable Connection for Torque Sensors-8

Accessories Cable General Technical Data Protection Class IEC/EN 60529 LiYCY transparent shielded Temperature range Bending radius approx. 10x outside diameter Data sheet see www.kistler.com Accessories Type Page 8/30 This information corresponds to the current state of knowledge. Kistler reserves the right to make technical changes. Liability for consequential damage resulting from the use of Kistler products is excluded. ©2007 ... 2024, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland phone +41 52 224 11 11, Fax +41 52 224 14 14, [email protected], www.kistler.com Kistler is a registered...