LOM-510A

LOM-510A

LOM-510A

Product catalog summary
Overview: The LOM-510A is a high-accuracy micro-ohmmeter designed for precise low resistance measurements. It features a 4½ digit display, 0.02% basic accuracy, and 1 μΩ resolution. The device uses a 4-terminal measurement technique to eliminate lead resistance errors and offers 80 dB of AC noise rejection for stable readings in noisy environments.
Measurement Modes:
  • Switched DC Mode: Suitable for measuring switch contacts, welds, and other resistive elements, eliminating thermal EMF effects.
  • Constant DC Mode: Ideal for measuring inductive components like coils and transformers.
  • Pulsed Mode: Provides low drive current for measuring thermally sensitive devices such as fuses and thermistors.
  • Dry Circuit Mode: Limits open circuit voltage to prevent puncturing oxides and film contacts.
Specifications:
  • Accuracy: 0.02% + 2 counts + 2 μΩ for switched DC, 0.04% + 2 counts + 2 μΩ for continuous DC, and 0.02% + 4 counts + 2 μΩ for pulsed mode.
  • Noise Rejection: 80 dB for switched DC and pulsed mode, 60 dB for continuous DC mode.
  • Measurement Rate: 1.5 readings per second.
  • Temperature Range: Operating: 15° to 30°C, Storage: 0°C to 40°C.
Accessories: The LOM-510A comes with various accessories including Kelvin test clips, microprobes, and a calibration kit. Optional accessories include extra-long cables for remote testing and heavy-duty Kelvin clips for large components.
Ordering Information: The document provides detailed ordering information for various cable assemblies and test fixtures compatible with the LOM-510A.
See more

Catalog excerpts

LOM-510A-1

LOM-510A Features and accessories to assure that very low resistance measurements are accomplished accurately, easily, and economically. Features: • 1 pQ resolution • 0.02% basic accuracy • Digital output • Four measurement modes • Auto-zero switched dc mode • Probes for chips and traces • New switch design, improves reliability • New external voltage selector switch • New IEC inlet adapter with fuse The LOM-510A has 4% digits, 0.02% basic accuracy and 1 pO resolution. Its 4-terminal measurement technique eliminates lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The unit comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown. Switched dc Mode: Allows measurement of switch contacts, welds, shunts, PC board tracks and other primarily resistive elements. Thermal emf effects are eliminated. Constant dc Mode: Suitable for measuring the resistance of inductive components such as coils or transformers. Pulsed Mode: Provides low drive current to allow measurements of fuses, thermistors, and other thermally sensitive devices. Dry Circuit: Assures that oxides and film contacts are not punctured. The Dry Circuit Mode limits the open circuit voltage to 50 mV. The Model LOM-510A/20 limits the open circuit voltage to 20 mV. Model LOM-510A Micro-ohmmeter shown with LOM-501C Standard 4-Terminal Kelvin clips Accuracy: SW (switched dc): 0.02% + 2 counts +2 pO dc (continuous dc): 0.04% + 2 counts + 2 pO Pulsed mode: 0.02% + 4 counts + 2 pO Zero Adjust: Active only in DC (Continuous dc) mode. Noise Rejection: 80 dB for SW (Switched dc) and Pulsed Mode 60 dB for DC (Continuous dc) mode. SW (Switched dc) Mode: Current switched on for 166 ms, then off for 500 ms (25% duty cycle). Pulsed Mode: One cycle of SW (Switched dc) mode; enabled by shorting two contacts on rear panel connector. Display: 4% digit, 0.5 inch, red LED display. Display Overrange Indication: Flashes for DC (Continuous dc) and SW (Switched dc) blanks in Pulsed mode Measurement Rate: 1.5 readings/second Connections to Unknown: 4-terminal Kelvin leads with shield Outputs: 5 BCD digits for value and polarity; Pulsed Mode Control lines; power supply lines; 25 pin "D" connector. Warm up time: 1 minute to rated accuracy Accuracy vs. Temperature: Stated accuracy applies over an ambient temperature range of 18 to 27 °C. Error doubles over the range of 10 to 40 °C. Accessories Supplied: LOM-501 test clips Power Requirements: 105-125 Vac or 210-250 Vac; 50-60 Hz selectable on rear panel 30 W max. Mechanical: Dimensions: 22.9 cm W x 5.1 cm H x 27.9 cm D Temperature Range: 15° to 30°C Storage Range: 0°C to 40°C A convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of the micro-ohmmeter. in the Gennaa Tradition www.ietlabs.com

 Open the catalog to page 1
LOM-510A-2

High Accuracy Micro-Ohmmeter LOM-510A ACCESSORIES 4-Terminal General Purpose Kelvin Clips Cable Assembly: LOM-501C 4-Terminal Kelvin Microprobes Cable Assembly: LOM-506 Suitable for connection in most applications Suitable for: - chips • Fine-point, springVersions • Jaw-Opening - 3/8" - circuit board components loaded tips (1.27 mm) LOM-501C - 1m (39") • Miniature Tips - conductor traces LOM-501C-2m - 2m (79") • Rugged - inside of connectors LOM-502C - clips only LOM-501 U - unterminated cable Wide Opening Kelvin Clips Cable Assembly: LOM-501W 4-Terminal Heavy Duty Kelvin Clips Cable Assembly:...

 Open the catalog to page 2

All Iet Labs catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.