HT-E-30 - 1

HYCOM DATASHEET MOBILE HYDRAULIC TEST STAND FOR AIRCRAFT MAINTENANCE MODEL HT electric driven MAINTENANCE AND OVERHAUL CHECKS OF AMM / ATA CHAPTER 29 FILLING AND DRAINING OF AIRCRAFT RESERVOIR FLUSHING OF AIRCRAFT HYDRAULIC SYSTEM TO CLASS 6 NAS1638 OR BETTER HYDRAULIC SUPPLY FOR RAT TESTS WITH HYCOM GROUND CHECK MOTOR FLOW RANGE OUTPUT = S : SINGLE SYSTEM = S2 :

Open the catalog to page 1
HT-E-30 - 2

FEATURES • Single system (S): one pressure and one return line or • Dual system (S2): single system with two pressure and two return lines with shutoff valves • • • • Axial piston pump variable stroke with proportional control of flow and pressure Boost pump for closed loop circuit Stainless steel reservoir of 240 liter with drain valve and filling cap Fluid contamination level NAS 1638 class 6 or better Oil-air cooler with low noise level suitable for tropical conditions Open loop configuration for filling and draining of A/C reservoir Temperature and boost pressure shut down switches Oil...

Open the catalog to page 2
HT-E-30 - 3

OPERATOR PANEL A Digital display with failure and maintenance notifications B Digital readout of acutal flow C High and return pressure gauges

Open the catalog to page 3
HT-E-30 - 4

TECHNICAL DATA GENERAL Main power supply cable Hydraulic hoses – single system Hydraulic hoses – dual system Noise level 12 meter 9 meter 12 meter less than 75 dbA at 2 meters distance HYDRAULIC Fluid HTM Fluid HTC Mineral based e.g. MIL-H-5606, MIL-H-83282 or MIL-H-87257 Phosphate ester based e.g. Skydrol or Hyjet 300-3000 psi at 30 USGPM, 4000 psi at reduced flow High (3 micron) and low pressure (10 micron) filters with electric clogging indicators MEASUREMENT High pressure gauge 0-5000 psi Accuracy 1% of full scale Return pressure gauge 0-200 psi Accuracy 1% of full scale Digital readout...

Open the catalog to page 4
HT-E-30 - 5

DIMENSIONS & WEIGHT Quick disconnect couplings to connect hoses to the aircraft High accuracy flowmeter, 0,3% of actual value PUR = Integrated purifier for filtering, degassing and dewatering PC = Integrated particle counter and water sensor Other options and accessories are available upon request.

Open the catalog to page 5
HT-E-30 - 7

HYCOM B.V. P.O. BOX 1079 | 7301 BH APELDOORN ANTILLEN 43 | 7333 PE APELDOORN T +31 88 0597 200 E INFO@HYCOM.NL | W WWW.HYCOM.NL

Open the catalog to page 7

All Hycom B.V. catalogs and technical brochures

  1. HTT

    6 Pages

  2. HRT-07

    5 Pages

  3. HRT-05

    5 Pages

  4. HPM-02

    6 Pages

  5. HRT-02

    6 Pages

  6. HRK-02

    6 Pages

  7. HRK-01

    6 Pages

  8. HFP-04

    7 Pages

  9. HRT-01

    6 Pages

  10. HT-F-30

    7 Pages

  11. HT-E-15

    7 Pages

  12. HFK-02

    6 Pages