1. Catalogs
  2. Hughey and Phillips
  3. Field Lightning Arrestor

Field Lightning Arrestor

Field Lightning Arrestor

Product catalog summary
Ordering Information
The Field Lightning Arrestor can be ordered using the part number A3-06-1162-001.
Compliances
The product exceeds the requirements of AC 150/5345-10, Section 3.4.12, which pertains to Lightning/Surge Arrestors.
Product Application
The Astronics DME Field Lightning Arrestor is designed to protect airfield lighting fixtures and electrical vault equipment from transient activities like lightning strikes and power surges. It is recommended to install these arrestors on the 5kV primary series circuit, starting near the vault and then approximately every 2,000 feet (600m). Closer intervals can be used for enhanced protection.
Features
  • Compatible with any airfield circuit (6.6A from 4 kW to 30 kW and 20A from 15 kW to 70 kW).
  • No maintenance required; replace if a unit fails.
  • Can be installed in a base can or direct earth buried.
  • Made from waterproof fiberglass-reinforced plastic (meets IP68).
  • Compatible with all types of Constant Current Regulators, light fixtures (Quartz and LED), and isolation transformers.
  • Includes a ¼”-20 stainless steel stud for solid ground connection for #6 AWG or larger ground wire.
  • Maximum continuous operating voltage: 5000VAC.
  • Series resistance: “0” Ohms.
  • Peak surge current: 25kA.
Weight and Dimensions
  • Weight: Approximately 5 lbs. per unit.
  • Dimensions: Length 5.91 inches, Height 5.91 inches, Depth 3.94 inches.
See more

Catalog excerpts

Field Lightning Arrestor-1

Field Lightning Arrestor POWER & CONTROL EQUIPMENT - 4.9 ORDERING INFORMATION Description Part Number WEIGHT AND DIMENSIONS Weight: Dimensions: Length Height Depth 5.91 inches 5.91 inches 3.94 inches COMPLIANCES Exceeds requirements of AC 150/5345-10 (current edition), Section 3.4.12 (Lightning/Surge Arrestors) PRODUCT APPLICATION The Astronics DME Field Lightning Arrestor is designed to help provide circuit protection from transient activity (such as lightning strikes or power surges) that can potentially damage lighting fixtures on an airfield and equipment located in an electrical vault. It is recommended that arrestor units be installed on the 5kV primary series circuit, starting as close to the vault as possible and then approximately every 2,000 feet (600m). Arrestors may be installed at closer intervals, if desired, to further reduce the risk of lightning/surge damage. FEATURES • May be installed on any airfield circuit (6.6A from 4 kW to 30 kW and 20A from 15 kW to 70 kW). • No maintenance required. If a unit fails, simply replace it with a new one. • A unit may be installed in a base can or direct earth buried. • The enclosure is made from fiberglass-reinforced plastic and is waterproof (meets IP68). • Arrestors are compatible with all types of Constant Current Regulators, light fixtures (Quartz and LED), and isolation transformers. • A ¼”-20 stainless steel stud provides solid ground connection for #6 AWG or larger ground wire. • Maximum continuous operating voltage: 5000VAC • Series resistance: “0” Ohms • Peak surge current: 25kA 6830 NW 16th Terrace • Ft. Lauderdale, FL 33309 USA Phone: 1.954.975.2100 • E-mail: [email protected] www.astronics.com/airfieldlighting Actual product specifications may have changed since the printing of this brochure. Brochure specifications are not binding. Confirm current specifications at time of order.

 Open the catalog to page 1

Archived catalogs

  1. L-801

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.