VR10-3A

VR10-3A

Product catalog summary
Title: Air Stop Valve VR10-3A
Specifications:
  • Fluid Media: Waste Water
  • Pressure Rating: Operating: -690 mbar max, Proof: 975 mbar, Burst: 1303 mbar min
  • Temperature Range: Operating: +1°C to +70°C, Storage: -55°C to +85°C
  • Crack Pressure: 400 mm W.C. (+/- 15%) at -600 mbar vacuum at outlet
  • Leakage: External = 0, Internal = 0 at -138 mbar to -975 mbar vacuum at outlet and 400 mm W.C. head at inlet
  • Flow Rate: 5 L/M @ 400 mm W.C. inlet at 0 mbar to -672 mbar vacuum at outlet
  • Material: Cap, Nut & Adjuster = Aluminum Alloy Type II Anodized; Seals & Diaphragm = NBR; Housing, Inlet & Outlet = Ultem 1000; All Internal Parts = Acetal
  • Weight: 0.25 Kg max
  • Manual Pull Ring: 10 mm opening, Pull force <75N direct on the pull ring
  • Backflow Check Valve: Incorporated in the assembly outlet fitting, 0 leakage from 5 mbar to 700 mbar
  • Marking: Hebmüller SRS Technik GmbH, Air Stop Valve, VR10-3A, S/N..................
  • Installation: Refer to document "VR10-3A_MOUNT_INSTRUCTION"
  • Particle Passage: Allows particles up to 2mm max, designed for waste water
Standards and Norms:
  • Tolerances: DIN ISO 2768 (middle)
  • Surface: DIN ISO 1302
Additional Information:
  • Fitting end per AS5131-16 2 PLS
See more

Catalog excerpts

VR10-3A-1

NOTES: I. FLUID MEDIA: WASTE WATER 2. PRESSURE RATING: OPERATING, -690 mbar MAX PROOF, 975 mbar BURST, 1303 mbar MIN 3. TEMPERATURE RANGE: OPERATING, +1 °C TO +70 °C STORAGE, -55°C TO + 85°C 4. CRACK PRESSURE: 400 mm W.C. (+/- \5%) AT -600 mbar VACUUM AT OUTLET 5. LEAKAGE: EXTERNALS, INTERNAL = 0 AT -138 mbar to -975 mbar VACUUM AT OUTLET AND 400 mm W.C. HEAD AT INLET 6. FLOW RATE = 5 L/M @ 400 mm W.C. INLET AT 0 mbar TO -672 mbar VACUUM AT OUTLET CAP, NUT & ADUUSTER = SEALS & DIAPHRAGM = NBR, HOUSING, INLET & OUTLET = ULTEM 1000 ALL INTERNAL PARTS = ACETAL ALLOY TYPE 9. MANUAL PULL RING = 10 MM OPENING PULL FORCE <75N DIRECT 12. FOR VALVE INSTALLATION PLEASE ATTEND TO DOCUMENT "VRI0-3A_MOUNT_INSTRUCTION" 13. THE VALVE IS ABLE TO LET PASS PARTICLES WITH A SIZE OF 2MM MAX. THE INNER SURFACES ARE DESIGNED FOR WASTE WATER ALLgeme intol. Tolerances DIN ISO 2768 m i ttel/m i ddle Bearb. Drawn Gepr. CHECK OberfL ache Surface DIN ISO 1302 Werkstoff/MATERIAL: Halbzeug: — AIR STOP VALVE VR I 0-3A HEBMULLER SRS TECHNIK GmbH Bro icherse ite 17 41564 Kaarst

 Open the catalog to page 1

All Hebmüller Aerospace catalogs and technical brochures

  1. VC200-6F

    1  Page

  2. VC203-08F01

    1  Page

  3. VC2-04NPT

    1  Page

  4. VC105P-8H

    1  Page

  5. VC105U-8H

    2  Pages

  6. hebvc2-08t01

    1  Page

  7. hebvc105p-8h

    1  Page

  8. VC100-6T

    1  Page

  9. VC100-04NPT

    1  Page

  10. VR10-17

    1  Page

  11. VR10-10A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.