Overview:
This document provides comprehensive technical specifications and features of VPX Power Supplies in 3U and 6U formats, designed by Hartmann Electronic GmbH. These power supplies are utilized in micro-computer systems and support various architectures, offering both air-cooled and conduction-cooled versions.
1. Power Supply 3U 4TE 715W, DC/DC, Conduction Cooled:
  • Key Features: Compliant with VITA 62, delivers up to 715W power with efficiency up to 88%, operates between -40 to +85°C, and features voltage sense control.
  • Technical Specifications: Includes input/output insulation, maximum output power, and protection features such as overvoltage and temperature protection.
  • Compatibility: Adheres to standards like VDE 0805 and IEC 950, tested for altitude, vibration, and shock.
  • Switch-On Behavior: Outputs switch on with a smooth exponential voltage rise.
2. Power Supply 3U 10HP 600W, AC/DC, Air Cooled:
  • Key Features: Offers efficiency up to 89%, input voltage range of 85-264Vac, and cooling via a low noise fan.
  • Technical Specifications: Includes input/output insulation, maximum output power, and protection features like overcurrent and temperature protection.
  • P0 Connector Pin Out: Provides detailed pin assignments for voltage and current.
3. Power Supply 6U 8HP 1300W, DC/DC, Air & Conduction Cooled:
  • Key Features: Compliant with VITA 62, provides up to 1300W power with efficiency up to 92%, available in air or conduction cooled versions.
  • Technical Specifications: Includes input/output insulation, maximum output power, and protection features.
  • Front Panel and LED Status: Overview of front panel elements and LED indicators for power and failure status.
4. Power Supply 6U 10HP 850W, AC/DC, Air Cooled:
  • Key Features: Efficiency of 86% at 230VAC, input frequency of 47-63Hz, and output power up to 850W.
  • Regulation: Line regulation typically 1%, load regulation ±2%.
  • Temperature: Operating range from -40°C to +70°C, storage from -45°C to +85°C.
5. LED Indicators:
  • CH1/2, CH3, and various auxiliary voltages have green LEDs indicating power status. LED ON means power is within the specified range, while LED OFF indicates it is not.
6. VPX Power Systems:
  • Available in 3U and 6U form factors.
  • Air-cooled and conduction-cooled versions are detailed with components like guide rails, handles, and converters.
7. Technical Specifications:
  • Form Factor: 6U, Pitch: 8HP, Weight: 2.0 kg.
  • Temperature Range: Storage: -55°C to 85°C, Operating: -40°C to 85°C.
  • Input/Output: Insulation of 1500V, Maximum Output Power of 1300W, Input Voltage ranges from 12V to 24Vdc.
  • Efficiency: Up to 92% for 12V, 85% for 3.3V, and 90% for 5V.
  • Protection: Overvoltage, temperature, and overcurrent protections are included.
8. Connectors:
  • P0 and P1 connectors have detailed pinouts for voltage and current assignments, including auxiliary power and signal returns.
9. Available Accessories:
  • Various power-backplanes and modules are available, designed for different input voltages and parallel operations.
Figures and Diagrams:
The document includes block diagrams and front panel illustrations to provide visual understanding of the power supplies' design and functionality.
See more

Catalog excerpts

VPX Power Supplies-3

Impressum: Hartmann Electronic GmbH Motorstraße 43, D-70499 Stuttgart (Weilimdorf) Telefon + 49 711 1 39 89-0 Telefax + 49 711 8 66 11 91 E-mail [email protected] Internet www.hartmann-electronic.com Hartmann Electronic is an established leader in the design and manufacturing of backplanes and electronic packaging for micro-computer systems. With over 30 years of experience in high-speed backplane design and manufacturing, Hartmann offers an extensive range of standard backplanes and system platform products supporting architectures including VME/64x, CompactPCI/2.16, AdvancedTCA,...

 Open the catalog to page 3
VPX Power Supplies-5

1 Power Supply 3U 4TE 715W, DC/DC, conduction cooled 1.1  Compliant to VITA 62 baseline specification  Up to 715 Wmax. Power *  600 W over all  up to 21A for +12V :VS1  up to 50A for +3.3V :VS2  up to 40A for +5V :VS3  +12V / -12V AUX 4.2A  +3V3 AUX 7A  up to 88% efficiency  -40 to +85°C Operating Temperature **  Voltage sense controlled ***  19 – 35 V DC INPUT  Minimum Input Voltage start up rise time > 50 V/s * Derating: ~2% Wattage per Kelvin from 40°C on ** ** At hottest outer case temperature / wedge lock edge temp. values in work *** Over Voltage, Under Voltage, Over Current,...

 Open the catalog to page 5
VPX Power Supplies-6

Figure 1 Block diagram 3U All voltage ZVS converters are isolated (1500V isolation voltage) and fed via a common Filter Network from the same 28V main supply (19V – 35V, shortly 36V). 3V3aux is not independent but protected by a resettable fuse (PTC). All individual output voltages (6x) are sensed by window comparators for over- and under voltages which are monitored from a central control logic device (CPLD). Any failure on the output voltages are signaled on the front panel by corresponding FAIL LEDs and lead to a switch off of all voltages (by default). If all internals are normal the blue...

 Open the catalog to page 6
VPX Power Supplies-7

Figure 2 Front panel functional elements of the VPX3C Power Supply 1.1.3 Control Logic: Depending on the main bus signals also the green RUN LED goes on and the power supply tries to start working. According to VITA 62 and VITA 46 the logic run line condition is – when “#” is nomenclature for the negative logic main bus signals, logic negation is signaled by the “¬” sign, and a positive logic transition by “↑”: RUN = ( ¬ #ENABLE AND #INHIBIT AND #FAIL AND ¬INTERNAL_FAIL ) “REFRESHED AFTER FAIL WHEN” ↑ ( ¬ #SYSRESET) This means that if the global inhibit is not set (= released to H), whether no...

 Open the catalog to page 7
VPX Power Supplies-8

Main Power Maximum Output Power Maximum Input Power Maximum Dissipated Power @ max. Power Minimum Turn ON Voltage Minimum Turn OFF Voltage Hysteresis Maximum Continuous Input Voltage Maximum Short Time Input Voltage Maximum Currents 12V / 3V3 / 5V Fixed Switching Frequencies 12V / 3V3 / 5V Peak Efficiencies 12V / 3V3 / 5V Max. Output Ripple and Noise: 12V / 3V3 / 5V (0-20 MHz Bandwidth) Line Regulation: 12V / 3V3 / 5V. Vin=Vin,min to Vin,max, Io and Tc fixed Load Regulation: 12V / 3V3 / 5V Vin=Vin,nom, Io=Io,min to Io,max, Tc fixed Controlled Overvoltage Protection: +/-12V / 3V3 / 5V Uncontrolled...

 Open the catalog to page 8
VPX Power Supplies-9

1.1.5 Compatibility VDE 0805 IEC 950 Tested and passed: - Altitude: MIL-STD-810F, Methode 500.4, Procedure II - Vibration: MIL-STD-810G, Methode 514.6 D-1, Category 12 - Shock: MIL-STD-810F, Methode 516.6, Procedure I

 Open the catalog to page 9
VPX Power Supplies-10

1.1.6 Switch-On Behavior All voltage outputs are switched on exponentially with relatively slow rise times of 30-80 ms and do settle smooth to the final voltage without any overshoot or glitch. Figure 3 Startup Delay and Exponential Rise (orange) of VS1 = 12V Output Voltage The power supply has to be switched on by a source of a minimum ramp up speed of the 28V source voltage of > 50 V/s or a maximum ramp up time < ~500 ms. If the ramp up time is longer than half a second the control logic may stall during switch on.

 Open the catalog to page 10
VPX Power Supplies-11

2 Power Supply 3U 10HP 600W, AC/DC, air cooled 2.1 Form factor: 3 U/10HP Efficiency: up to 89% Input Frequency: 47-63Hz Input Voltage: 85 – 264Vac Input Current: 6A (600W output at 120Vrms input) Inrush Current: 20A (at 265Vrms) Output Voltage: 12V/28A: VS1 3.3V/19A: VS2 5V/25A: VS3 ±12VAUX/1A 3V3AUX/6A Isolation Voltage: Input to Output:4000Vac Input to Chassis: 1500Vac Output to Chassis 250Vdc Output to Output 250Vdc Cooling with low noise Fan installed Used in parallel mode with Hartman PSUs and Power-Backplanes

 Open the catalog to page 11
VPX Power Supplies-12

2.2.1 Technical Specification Form Factor Pitch Weight Storage Temperature Operating Temperature Input to Output Insulation Input Input Voltage Input Current: Inrush Current: Output Maximum Output Power (85 – 264Vac) Max. Currents 3.3V / 12V / 5V Over Current Protection (% of rated current) Ripple and Noise (20MHz BW, pk – pk) Holdup Time (600W output at120Vrms input) Turn ON Rise Time 3.3V / 12V / 5V Turn ON Delay (AC to PG) 3.3V / 12V / 5V Line Regulation: 3.3V / 12V / 5V Load Regulation: 3.3V / 12V / 5V Overvoltage Protection: 3.3V / 12V / 5V / Over Temperature Protection (internal monitored.)...

 Open the catalog to page 12
VPX Power Supplies-13

Voltage +12V +3,3V Return of all output +5V GND_SENSE +5V_SENSE +3,3V_SENSE +12V_SENSE UD0 ENABLE INHIBIT FAIL VBAT UD4 UD3 UD2 UD1 CHA_GND Line Neutral

 Open the catalog to page 13
VPX Power Supplies-14

3 Power Supply 6U 8HP 1300W, DC/DC, air & conduction cooled 3.1            Key Features Compliant to VITA 62 baseline specification 1.300 W over all up to 100A for 12V up to 70A for 5V, (80A)* up to 30A for 3.3V, (50A)* +12V / -12V AUX 1,25A up to 92% efficiency -40 to +85°C Operating Temperature Voltage sense controlled 24V or 48V DC INPUT conduction cooled or air cooled *customized possible 24V air cooled 12V: D575.00502  24V DC Input (18V to 36V)  +12V / -12V AUX 1.25A 87% efficency  +3.3V AUX 30A 85% efficency  +12V 100A 92% efficency 24V air cooled 5V: D575.00512  24V DC...

 Open the catalog to page 14
VPX Power Supplies-15

VPX Power 3U / 6U All voltage converters are isolated (1500V isolation voltage) and fed from the same 24V main supply (18V – 36V) protected by two (DCin1, DCin2”) 40A fuses. The “Power LED” is controlled by the “Power Good Signal” of the 12V converter. The output voltages (+12V, +5V, 3,3V) are sensed for over- and under voltages which are monitored from the control logic in every converter. Any failure on the output voltages are signalled on the front panel by corresponding FAIL LED (OFF). In according to Vita62, the “FAIL-Signal” is connected to the “FAIL Pin” (B2) at the P1 connector. If all...