Aura AI
2Pages

{{requestButtons}}

Catalog excerpts

Aura AI - 1

Aura Ai-2PERIMETER INTRUSION DETECTION > NEXT GENERATION TECHNOLOGY The Aura Ai-2 is the next generation controller from FFT, and offers superior detection of fence climbing, cutting or lifting. With a maximum sensor length of 60km (37 miles) the Aura Ai-2 controller can detect, locate and report disturbances to within ± 1 to 4m (3.3 to 13ft) of the event. Industry Leading Intrusion Detection The Aura Ai-2 controller pulses laser light down optical fibers connected to each of its two detection channels. Sensing fibers are housed inside sensor cables attached to the perimeter fence. Fence disturbances cause sensor cable movement and changes in reflected laser light. The Aura Ai-2 controller automatically analyzes the reflected light to detect, locate and report disturbances. Aura Ai-2 uses the latest advanced optical signal processing algorithms, combined with artificial intelligence, to discriminate between intrusions, nuisance alarms and other causes of fence disturbance. Aura Ai-2's decision making software intelligently analyzes fiber optic laser measurements and automatically adjusts controller settings to optimize sensitivity for reduced nuisance alarms and increased probability of detection. Resistance to Nuisance Alarms Aura Ai-2's artificial intelligence and advanced signal discrimination prevents nuisance alarms while maintaining maximum sensitivity to intrusion events which makes this solution suitable for a wide range of applications including: • Intelligence Agencies • Armed Forces • Power Stations • Airports • Nuclear Facilities • Correctional Facilities • Oil and Gas • Borders

Open the catalog to page 1
Aura AI - 2

Sensor Cable Even when a sensor fiber is cut or damaged, Aura Ai-2 continues to detect perimeter intrusions occurring between the controller and the cut. When sensor fibers are connected to two channels of the controller (or two controllers) in a redundant loop configuration, intrusions can be detected to within 10m (33ft) either side of the cut. Channel One Fiber Channel Two Fiber Channel One and Channel Two End Elements HOW IT WORKS 1) Sensor cables are connected to the fence fabric using cable (zip) ties 2) single optical fiber inside the sensor cable(s) is connected to each Aura Ai-2...

Open the catalog to page 2

All Future Fibre Technologies catalogs and technical brochures

  1. Aura IQ

    2 Pages

  2. AURA LR

    4 Pages

  3. CAMS

    4 Pages

  4. sECURE LINK

    4 Pages