OLS5000 - 1

Your Vision, Our Future 3D Measuring Laser Microscope

Open the catalog to page 1
OLS5000 - 2

Laser Microscope Solutions Sub-micron 3D observation/ measurement Observe steps in the nanometer range and measure height differences at the sub-micron level. ISO25178-compliant surface roughness measurement Measure surface roughness from linear to planar. Non-contact, nondestructive, and fast No sample preparation required—simply place the sample on the stage and you're ready to measure.

Open the catalog to page 2
OLS5000 - 3

Conventional measuring tools Optical microscope, digital microscope Unable to measure small shapes Poor lateral resolution Non-traceable measurement results Laser microscope 0.12 μm lateral resolution Traceable measurement results Stylus surface roughness tester Can damage the sample’s surface Information from only one line Difficult to place the stylus on a target position Non-contact measurement doesn’t damage the sample Acquire information from an entire plane Pinpoint measurement White light interferometer Has difficulty capturing rough surface shapes Poor lateral resolution makes...

Open the catalog to page 3
OLS5000 - 4

Capture the shape of any surface. LEXT OLS5000 3D Measuring Laser Microscope Get reliable data quickly. Simple to use—just place your sample and press a button. Measure challenging samples. 6

Open the catalog to page 4
OLS5000 - 5

Uniform measurements in the entire visual field Dedicated LEXT Objectives Capture steep slopes up to 87.5° 4K Scan Technology Automatically acquire reliable data Smart Judge function 4 times faster Fast, accurate measurements from low to high magnifications PEAK Algorithm Save time during step shape measurements Skip Scan Value ► P. 10 Acquire accurate data with the press of a button Smart Scan II Create comprehensive reports Easy Analysis Reduce the variance between repeated measurements Analysis Templates Accommodates tall samples (up to 210 mm high) Extension Frame Measure dented...

Open the catalog to page 5
OLS5000 - 6

Capture the shape of any surface The OLS5000 microscope’s advanced technology enables it to capture high-resolution measurements of 3D samples. Technology that delivers reliable data Uniform measurement values Dedicated LEXT objectives Long WD types (20x/50x/100x) Dedicated LEXT objectives With previous lens, aberrations made it difficult to accurately measure peripheral areas. Distortion increases at the periphery. Dedicated LEXT objective lenses can accurately measure peripheral areas. The periphery is reproduced free of distortion.

Open the catalog to page 6
OLS5000 - 7

4K Scan Technology Details on P.17 A sample with steep angles (razor blade) Previous model: unable to accurately measure steep slopes. Capture the shape of steep slopes OLS5000 microscope: accurately detects slopes as steep as 87.5°. Automatically acquire reliable data Smart Judge function Details on P.18 Measurement noise is incorrectly displayed as repaired images. Previous model: Eliminating noise also eliminates original data. Measurement noise is accurately displayed, minimizing the risk of ambiguous results. OLS5000 microscope: Data and noise are automatically detected for accurate...

Open the catalog to page 7
OLS5000 - 8

Get reliable data quickly The microscope’s scanning algorithm delivers improved data quality and improved speed to reduce scan time and streamline your workflow, resulting in improved productivity. Technologies that deliver speed Fast, accurate measurements PEAK Algorithm Details on P.17 Measurement time Measurement accuracy Hard to detect steps due to noisy data Conventional model Not possible at the same time times faster Both possible at the same time with OLS5000 High High Speed Accuracy BOTH Data acquisition time Close to the true value with only minor fluctuations VLSI standard 83nm...

Open the catalog to page 8
OLS5000 - 9

Streamlined measurement improves efficiency Skip Scan Details on P. 22 Value2 Get reliable data quickly Conventional model Skips scanning this section Scan every area Scan required area only Previous model Data acquisition time

Open the catalog to page 9
OLS5000 - 10

Simple to use – just place your sample and press a button The OLS5000 microscope features automatic data capture so difficult setting adjustments are no longer necessary. Even users with minimal training can still obtain accurate results. Technologies that deliver ease of use Accurate data at the press of a button Smart Scan II Details on P. 22 Place the sample and set the area to be measured.

Open the catalog to page 10
OLS5000 - 11

Good results no matter your experience level Easy Analysis Details on P. 24 Specify the measurement area. Select item Specify area Click report Analysis and reporting completed. Value 3 Simple to use – just place your sample and press a button Reduced variance between repeated measurements Analysis Templates Details on P.30 The report is created. When these steps are registered as the default template, all of the steps up to create report will be executed automatically next time.

Open the catalog to page 11
OLS5000 - 12

Measure challenging samples The low-output, non-contact, nondestructive laser means no sample preparation is required. Delicate materials can be measured without being damaged. The extension frame accommodates samples with a height of up to 210 mm, while the ultra-long working distance objective facilitates measurement of concavities as deep as 25 mm. In both cases, all you have to do is place the sample on the stage. Technologies that deliver flexibility Compatible with samples up to 210 mm tall Extension Frame Details on P.31 Compatible with various samples Piston head

Open the catalog to page 12
OLS5000 - 13

High-performance measurement Dedicated LEXT long working distance objectives Standard roughness sample 528 by Rubert & Co., Ltd. (Pt = 1.5 μm) Depth (from optical axis to the frame’s edge) Measure concavities 25 mm deep Ultra-long working distance objectives Details on P.31 Value 4 Measure challenging

Open the catalog to page 13
OLS5000 - 14

Advanced Technology Delivers Reliable Data Detecting fine patterns and defects Excellent Lateral Resolution The 405 nm violet laser and dedicated high-NA objectives make it possible to capture fine patterns and defects that conventional optical microscopes, white-light interferometers, or red laser-based microscopes are unable to detect. Red type ( 658 nm: 0.26 μm line & space) Violet type ( 405 nm: 0.12 μm line & space)

Open the catalog to page 14

All Evident - Olympus Scientific Solutions catalogs and technical brochures

  1. IPLEX GX/GT

    8 Pages

  2. 35 RDC

    2 Pages

  3. OLYMPUS LC30

    2 Pages

  4. CIX100

    16 Pages

  5. MX63/MX63L

    20 Pages

  6. SWTLU-C

    4 Pages

  7. GX53

    20 Pages

  8. MagnaFORM

    2 Pages

  9. Portable XRD

    2 Pages

  10. 45MG

    12 Pages

  11. 38DL PLUS

    12 Pages