Introduction to Spun Concrete Technology
Spun concrete technology utilizes a high-strength concrete mix with low water content, spun in a high-speed rotating mold to produce a smooth, dense surface. This process compresses the concrete against the mold, eliminating air voids and enhancing durability.

Design and Aesthetic Features
Columns can be circular, tapered, faceted, rectangular, or square, available in lengths up to 35 meters. They can have smooth or textured finishes and be pigmented in various colors to meet architectural needs.

Structural and Installation Benefits
Spun columns are designed to withstand bending moments, wind forces, shear stress, and gravity loads. They are lightweight, easy to handle, and increase usable floor space. Columns can be cast as continuous sections or single-storey elements with various end connections.

Manufacturing and Quality Assurance
Europoles ensures high-quality production with certified plants in Germany. The columns are fully engineered, fire-protected, and ready for installation, providing cost-effective construction solutions.

Design Possibilities and Customization
Spun columns offer extensive design possibilities, including slender profiles, various colors, textures, and cross-section geometries. They are suitable for both concrete and steel-framed buildings.

Technical Specifications
Preliminary design tables detail outer column diameters and load capacities for different lengths and reinforcement percentages.

Specifications
Characteristic loads are outlined in kN for various column dimensions. The hollow core should be at least one-third of the outer diameter. Loads are calculated according to DIN 1045/1, with fire-protection certification based on expert opinion.

Procedures
Installation methods include flat-steel anchors, Pfeifer sleeves, rod protrusion, and mandrel options. Various column head and foot configurations are detailed.

Norms and Standards
The document adheres to DIN 1045/1 standards for load calculations and fire protection, emphasizing the need for expert opinions for certifications.

Recommendations
Manufacturers can close the column head upon request. Pfeifer pigtail and flat-steel anchors are recommended for secure installation.

Key Data from Tables
Tables provide detailed load capacities for columns of varying dimensions, highlighting the importance of selecting appropriate sizes for specific load requirements.

Additional Information
All materials, including quotations, documents, and drawings, are copyrighted by Europoles GmbH & Co. KG and require written consent for use or reproduction.
See more

Catalog excerpts

Buildings & Security-1

Attached components (corbels) Roof drainage through centre of column Open spaces are later closed in the area of continuous reinforcement elements. Open spaces are later closed in the area of continuous reinforcement elements. Open spaces are later closed in the area of continuous reinforcement elements. Section A A Section A Sleeve Section B Open spaces are later closed in the Open spaces are later closed in the area of continuous reinforcement area of continuous reinforcement elements. elements. Spun Column Technology – A new dimension in concrete column innovation Section B Roughening provided at the column foot with knobbed film Expansion sleeve Open spaces are later closed in the area of continuous reinforcement elements. Side inspection and outlet Sleeve Outlet in foundation Sleeve Europoles GmbH & Co. KG Ingolstaedter Strasse 51 92318 Neumarkt / Germany Phone +49 9181 28-880 Fax +49 9181 28-514 [email protected] www.europoles.com

 Open the catalog to page 1
Buildings & Security-2

© H.G. Esch, Hennef, and Ingenhoven Architects, in Düsseldorf Aesthetics and design combined with innovation and technology · Figs. 1/3: Opera House Erfurt [ Jörg Friedrich + Partner, Hamburg ] Fig. 2: Lufthansa Aviation Center, Frankfurt [ Ingenhoven Architekten, Düsseldorf

 Open the catalog to page 2
Buildings & Security-3

InstallationInstallation of of columns incolumns in socket socket footings footings Installation with Installation with steel steel plate or plate or centering cone centering cone Foot plate Foot plate Filling with concrete by a concreting truck Compaction of the concrete in a rotational unit What is spun concrete technology? Column-head Column-head into integration integration into in-situ concrete Column-head in-situ concrete into Column-head integration integration into in-situ concrete in-situ concrete Punching Punching frame shear shearPunching frame Punching frame shear Telefon 81 28 PfleidererPfleiderer...

 Open the catalog to page 3
Buildings & Security-4

Figs. 1/4: Humboldt University; Berlin [Augustin und Frank Architekten, Berlin ]. Fig. 2: CityPaiais, Duisburg [ Chapman Taylor Architekten, Dusseldorf ]. Fig. 3: Kassel Wilhelmshdhe railway station [ Brandt & Bdttcher, Berlin; Peter Schuck, Kassel ] Fully Engineered The columns can be designed to resist most combinations of bending moment, wind force, shear stress and gravity loads arising from the building structure. As the spun columns can accommodate both prestressed and normal reinforcement arrangements the column can be engineered to produce the slimmest column section for any given loading...

 Open the catalog to page 4
Buildings & Security-5

Beautifully Finished Spun columns will always produce a dense, hardwearing, smooth exterior concrete finish due to the careful blend of the constituent materials, the low water cement ratio and compaction of materials as it is centrifuged. Choice of colour, surface texture and tone can be tailored to compliment the character of the building or make a visual impact. Light-fast inorganic pig­ ments that are chemically stable are used in the pigmented colour mixes. Bright, intense colours may be achieved with white concrete mixes while more earth tinted colours are produced using grey cements. Karstadt...

 Open the catalog to page 5
Buildings & Security-6

Elegantly Slender By prestressing the columns the con­ crete is put into compression, and this enhances its robustness and stabil­ ity, making it possible to manufacture very slender column sections. Techniques to manufacture columns with angled base plates, enables spun columns to be built with a splay or at a slanted alignment, offer­ ing innovative and imaginative column arrangements to frames and floors. The hollow column shell created by the spun concrete process not only reduces the weight of the columns, it also offers a hidden conduit for ser­ vices and for rainwater disposal. Centre...

 Open the catalog to page 6
Buildings & Security-7

A D D E D VALUE IN Q UALIT Y AN D P ER F ORMANCE Fig. 1: The Modern Pinakothek Museum, Munich [ Stephan Braunfels, Munich ] Fig. 2: Department for foreign affairs, Berlin [ Müller Reimann Architekten, Berlin ] Fig. 3: Grammar School, Markt Indersdorf [ Allmann Sattler Wappner Architekten, Munich ] Advantages at a glance · Slender column profiles with the finest surface finish Throughout Europe, the name Europoles Europoles combines innovation with · Delivery of columns ready for site installation construction at highest quality levels. the long experience of committed · Engineered, fully fire...

 Open the catalog to page 7
Buildings & Security-8

product design information Characteristic loads (service loads) in kN C 80/95 Percentage of reinforcement: 9 % i) HoIIow core of the column D, > 1/3 x Da. Loads in accordance with DIN 1045/1 fire-protection certification takes place in accordance with an expert opinion (project-related). Calculation with a*-rnethod. Conventional high-rise columns, with full-surface over the cross-section at the head and foot. Installation Installation Column head Column head (steel plate Column head (steel plate attached Column head (with flat-steel anchor) D 01 (Pfeifer sleeve) D 02 (rod...

 Open the catalog to page 8

All EUROPOLES SUISSE GMBH catalogs and technical brochures

  1. Energy

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.